Research on magnetostrictive liquid level gauge for water level measurement of steam generator
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The accurate measurement of the water level on the secondary side of the steam generator (SG) plays a crucial role in the safe and stable operation of the primary and secondary circuits of the nuclear power plant. In order to study the feasibility of applying the magnetostrictive liquid level gauge to the water level measurement of SG, the measurement results of the magnetostrictive liquid level gauge under the steady and transient conditions were obtained and compared with the traditional differential pressure liquid level gauge. The results indicated that the magnetostrictive liquid level gauge had good measurement accuracy under the cold-steady condition, thermalsteady condition and transient pressurization condition. The design parameters of float and operating parameters were necessary to correct the measurement results of magnetostrictive water level gauge. The measurement results under the transient depressurization condition were affected by the fluid movement in the container, resulting in a decrease in measurement accuracy. The results indicated that the magnetostrictive liquid level gauge had the potential to be used for water level measurement of SG in nuclear power plant.
Abstract
The accurate measurement of the water level on the secondary side of the steam generator (SG) plays a crucial role in the safe and stable operation of the primary and secondary circuits of the nuclear power plant. In order to study the feasibility of applying the magnetostrictive liquid level gauge to the water level measurement of SG, the measurement results of the magnetostrictive liquid level gauge under the steady and transient conditions were obtained and compared with the traditional differential pressure liquid level gauge. The results indicated that the magnetostrictive liquid level gauge had good measurement accuracy under the cold-steady condition, thermalsteady condition and transient pressurization condition. The design parameters of float and operating parameters were necessary to correct the measurement results of magnetostrictive water level gauge. The measurement results under the transient depressurization condition were affected by the fluid movement in the container, resulting in a decrease in measurement accuracy. The results indicated that the magnetostrictive liquid level gauge had the potential to be used for water level measurement of SG in nuclear power plant.
참고문헌 (22)
- A. K. Singhal, "A review of thermal hydraulic analysis methodology for pwr steam generators and athos3 code applications", Prog. Nucl. Energy, 25, pp.7~70 (1991)
- X. Zhao, "Threedimensional study on the hydraulic characteristics under the steam generator(sg)tube plugging operations for ap1000", Prog. Nucl. Energy, 112, pp.63~74 (2019)
- X. Yang, "Study on performance and operation mechanism of a separation equipment for a pwr steam generator", Atmosphere, 14, pp.451~465 (2023)
- S. Cho, "Fault detection and identification for sensor channels in steam generator level control loops", IEEE Trans. Nucl. Sci, 66, pp.771~781 (2019)
- M. V. Kothare, "Level control in the steam generator of a nuclear power plant", IEEE Trans. Control Syst. Technol, 8, pp.55~69 (2000)
- N. A. Demerdash, "Optimal feed-water level control for steam generator in nuclear power plant based on meta-heuristic optimization", J. Radiat. Res. Appl. Sci, 13, pp.468~484 (2020)
- Z. Dong, "Water-level control for the u-tube steam generator of nuclear power plants based on output feedback dissipation", IEEE Trans. Nucl. Sci, 56, pp.1600~1612 (2009)
- J. Bang, "Analysis of steam generator tube rupture accidents for the development of mitigation strategies", Nucl. Eng. Technol, 54, pp.152~161 (2022)
- Z. Zhang, "Performance assessment for the water level control system in steam generator of the nuclear power plant", Ann. Nucl. Energy, 45, pp.94~105 (2012)
- A. Salehi, "The μ–synthesis and analysis of water level control in steam generators", Nucl. Eng. Technol, 51, pp.163~169 (2019)
- X. Zhou, "Analysis of measuring characteristics of the differential pressure water-level measurement system under depressurization condition", Front. Energy Res, 8, pp.145~ (2020)
- Y. Chen, "Full-range steam generator’s water level model and analysis method based on cross-calculation", Prog. Nucl. Energy, 133, pp.103635~ (2021)
- Y. Chen, "Establishment and application of crosscomparison model on redundancy differential pressure type flow channels", Ann. Nucl. Energy, 125, pp.132~137 (2019)
- F. Xiong, "Optimization of steam generator water level measurement system in cpr1000 nuclear power plant", Instrumentation, 23, pp.95~97 (2016)
- T. Deng, "Study on measuring technology of the steam generator water level", Mar. Elect. & Electron. Eng, pp.57~59 (2005)
- V. I. Melnikov, "Waveguide ultrasonic liquid level transducer for nuclear power plant steam generator", Nucl. Eng. Des, 176, pp.225~232 (1997)
- Z. Deng, "New Energy Power Generation Automation and Intelligent Technology" (2023), Singapore
- Y. Singh, "Review on liquid-level measurement and level transmitter using conventional and optical techniques", IETE Tech. Rev, 36, pp.329~340 (2019)
- P. Mohindru, "Development of liquid level measurement technology: a review", Flow, Meas. Instrum, 89, pp.102295~ (2023)
- J. K. Lee, "Magnetostrictive patch sensor system for battery-less real-time measurement of torsional vibrations of rotating shafts", J. Sound Vib, 414, pp.245~258 (2018)
- H. C. Chang, "Magnetostrictive type inductive sensing pressure sensor", Sens. Actuators, A, 238, pp.25~36 (2016)
- Y. Li, "Development of magnetostriction sensor for on-line liquid level and density measurement", 2006 6th World Congress on Intelligent Control and Automation (2006)