ACL Reconstruction with Autologous Hamstring Tendon: Comparison of Short Term Clinical Results between Rigid-fix and PINN-ACL Cross Pin
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Purpose: To compare the short term clinical results of anterior cruciate ligament (ACL) reconstruction with autologous hamstring tendon between Rigid-fi x and PINN-ACL Cross Pin for femoral side fi xation. Materials and Methods: 127 patients who underwent arthroscopic ACL reconstruction using autologous hamstring tendon and had been followedup for over than one year were enrolled for the present study. Rigid-fi x was used in 71 cases (group 1), and PINN-ACL Cross Pin was used in 56 cases (group 2). Clinical and radiological results, operation time, and perioperative complications were compared amongst the two groups. Results: Th e International Knee Documentation Committee subjective score and Lysholm score were 94 and 95 in group 1 and 87 and 91 in group 2, with no statistical difference (p=0.892, p=0.833), respectively. However, significant difference was observed in one-leg hop test between the two groups (p=0.032). Five cases in group 1 and 40 cases in group 2 were found to be associated with perioperative complications with statistical diff erence (p<0.0001). Conclusions: Th ere was no resultant diff erence between the employment of PINN-ACL Cross Pin and Rigid-fi x as femoral graft fi xation for ACL reconstruction with hamstring tendon. However, PINN-ACL Cross Pin led to complications with extensive operation times. Hence, it needs further improvement of tools for minimization of complications.
Abstract
Purpose: To compare the short term clinical results of anterior cruciate ligament (ACL) reconstruction with autologous hamstring tendon between Rigid-fi x and PINN-ACL Cross Pin for femoral side fi xation. Materials and Methods: 127 patients who underwent arthroscopic ACL reconstruction using autologous hamstring tendon and had been followedup for over than one year were enrolled for the present study. Rigid-fi x was used in 71 cases (group 1), and PINN-ACL Cross Pin was used in 56 cases (group 2). Clinical and radiological results, operation time, and perioperative complications were compared amongst the two groups. Results: Th e International Knee Documentation Committee subjective score and Lysholm score were 94 and 95 in group 1 and 87 and 91 in group 2, with no statistical difference (p=0.892, p=0.833), respectively. However, significant difference was observed in one-leg hop test between the two groups (p=0.032). Five cases in group 1 and 40 cases in group 2 were found to be associated with perioperative complications with statistical diff erence (p<0.0001). Conclusions: Th ere was no resultant diff erence between the employment of PINN-ACL Cross Pin and Rigid-fi x as femoral graft fi xation for ACL reconstruction with hamstring tendon. However, PINN-ACL Cross Pin led to complications with extensive operation times. Hence, it needs further improvement of tools for minimization of complications.
참고문헌 (15)
- Ahn JH, "Comparison of the clinical results of the fixation techniques to femur in ACL reconstruction using hamstring double-loops: bioscrews vs. semi-Fix", J Korean Knee Soc, 11, pp.32~38 (1999)
- Amis AA, "Anterior cruciate ligament replacement. Knee stability and the effects of implants", J Bone Joint Surg Br, 71, pp.819~824 (1989)
- Corry IS, "Arthroscopic reconstruction of the anterior cruciate ligament. A comparison of patellar tendon autograft and fourstrand hamstring tendon autograft", Am J Sports Med, 27, pp.444~454 (1999)
- Goldblatt JP, "Reconstruction of the anterior cruciate ligament: meta-analysis of patellar tendon versus hamstring tendon autograft", Arthroscopy, 21, pp.791~803 (2005)
- Aune AK, "Interference screw fi xation of hamstring vs patellar tendon graft s for anterior cruciate ligament reconstruction", Knee Surg Sports Traumatol Arthrosc, 6, pp.99~102 (1998)
- Brand J Jr, "Graft fi xation in cruciate ligament reconstruction", Am J Sports Med, 28, pp.761~774 (2000)
- Eriksson K, "A comparison of quadruple semitendinosus and patellar tendon graft s in reconstruction of the anterior cruciate ligament", J Bone Joint Surg Br, 83, pp.348~354 (2001)
- Milano G, "Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft : a biomechanical analysis", Arthroscopy, 22, pp.660~668 (2006)
- Speirs A, "Evaluation of a new femoral fixation device in a simulated anterior cruciate ligament reconstruction", Arthroscopy, 26, pp.351~357 (2010)
- Freedman KB, "Arthroscopic anterior cruciate ligament reconstruction: a metaanalysis comparing patellar tendon and hamstring tendon autografts", Am J Sports Med, 31, pp.2~11 (2003)
- Laxdal G, "A prospective randomized comparison of bonepatellar tendon-bone and hamstring grafts for anterior cruciate ligament reconstruction", Arthroscopy, 21, pp.34~42 (2005)
- Charlton WP, "Clinical outcome of anterior cruciate ligament reconstruction with quadrupled hamstring tendon graft and bioabsorbable interference screw fixation", Am J Sports Med, 31, pp.518~521 (2003)
- Kousa P, "Th e fi xation strength of six hamstring tendon graft fi xation devices in anterior cruciate ligament reconstruction. Part I: femoral site", Am J Sports Med, 31, pp.174~181 (2003)
- Ahmad CS, "Mechanical properties of soft tissue femoral fi xation devices for anterior cruciate ligament reconstruction", Am J Sports Med, 32, pp.635~640 (2004)
- Zantop T, "Initial fi xation strength of two bioabsorbable pins for the fi xation of hamstring graft s compared to interference screw fi xation: single cycle and cyclic loading", Am J Sports Med, 32, pp.641~649 (2004)
