purpose: To evaluate the radiological stability according to the number of modular augments after revision of infected total knee arthroplasty (TKA). materials and methods: Between February 2006 and September 2013, 37 patients (39 knees) followed ≥2 years after revision of infected TKA using modular metal augments for bone defects were reviewed retrospectively. We divided the patients into 3 groups according to the number of augments into group A (≤2 augments, 14 knees), group B (3–4 augments, 18 knees), and group C (5≥ augments, 7 knees) and evaluated the width of radiolucent zones around the implant at the last follow-up.results: There were 3 Anderson Orthopedic Research Institute type I, 33 type II, and 3 type III bone defects. The mean number of radiolucent zones of group A was 3 and the sum of width averaged 4.4 mm. In group B, the values were 4.8 and 6.2 mm, respectively. In group C, the values were 8.1 and 12.9 mm, respectively. The differences between the three groups were statistically significant.conclusions: In revision TKA with modular metal augmentation caused by infected TKA, increased modularity can result in radiological instability.
Abstract
purpose: To evaluate the radiological stability according to the number of modular augments after revision of infected total knee arthroplasty (TKA). materials and methods: Between February 2006 and September 2013, 37 patients (39 knees) followed ≥2 years after revision of infected TKA using modular metal augments for bone defects were reviewed retrospectively. We divided the patients into 3 groups according to the number of augments into group A (≤2 augments, 14 knees), group B (3–4 augments, 18 knees), and group C (5≥ augments, 7 knees) and evaluated the width of radiolucent zones around the implant at the last follow-up.results: There were 3 Anderson Orthopedic Research Institute type I, 33 type II, and 3 type III bone defects. The mean number of radiolucent zones of group A was 3 and the sum of width averaged 4.4 mm. In group B, the values were 4.8 and 6.2 mm, respectively. In group C, the values were 8.1 and 12.9 mm, respectively. The differences between the three groups were statistically significant.conclusions: In revision TKA with modular metal augmentation caused by infected TKA, increased modularity can result in radiological instability.
참고문헌 (27)
- Completo A, "The influence of different tibial stem designs in load sharing and stability at the cement-bone interface in revision TKA", Knee, 15, pp.227~232 (2008)
- Ghazavi MT, "Reconstruction of massive bone defects with allograft in revision total knee arthroplasty", J Bone Joint Surg Am, 79, pp.17~25 (1997)
- Gross AE, "Revision total knee arthroplasty of bone grafts versus implant supplementation", Orthopedics, 20, pp.843~844 (1997)
- Panni AS, "Modular augmentation in revision total knee arthroplasty", Knee Surg Sports Traumatol Arthrosc, 21, pp.2837~2843 (2013)
- Bauman RD, "Limitations of structural allograft in revision total knee arthroplasty", Clin Orthop Relat Res, 467, pp.818~824 (2009)
- Clatworthy MG, "The use of structural allograft for uncontained defects in revision total knee arthroplasty : a minimum five-year review", J Bone Joint Surg Am, 83, pp.404~411 (2001)
- Dennis DA, "The structural allograft composite in revision total knee arthroplasty", J Arthroplasty, 17(4 Suppl 1), pp.90~93 (2002)
- Whittaker JP, "The management of bone loss in revision total knee replacement", J Bone Joint Surg Br, 90, pp.981~987 (2008)
- Hockman DE, "Augments and allografts in revision total knee arthroplasty : usage and outcome using one modular revision prosthesis", J Arthroplasty, 20, pp.35~41 (2005)
- Lucey SD, "A practical approach to dealing with bone loss in revision total knee arthroplasty", Orthopedics, 23, pp.1036~1041 (2000)
- Beckmann J, "Fixation of revision TKA : a review of the literature", Knee Surg Sports Traumatol Arthrosc, 19, pp.872~879 (2011)
- Conditt MA, "The optimal strategy for stable tibial fixation in revision total knee arthroplasty", J Arthroplasty, 19(7 Suppl 2), pp.113~118 (2004)
- Mulhall KJ, "Current etiologies and modes of failure in total knee arthroplasty revision", Clin Orthop Relat Res, 446, pp.45~50 (2006)
- 백승욱, "Management of Tibial Bony Defect with Metal Block in Primary Total Knee Replacement Arthroplasty", Knee Surgery and Related Research, 25(1), pp.7~12 (2013), 대한슬관절학회
- Brand MG, "Tibial tray augmentation with modular metal wedges for tibial bone stock deficiency", Clin Orthop Relat Res, 248, pp.71~79 (1989)
- Pagnano MW, "Tibial wedge augmentation for bone deficiency in total knee arthroplasty. A followup study", Clin Orthop Relat Res, (321), pp.151~155 (1995)
- Whaley AL, "Cemented long-stem revision total knee arthroplasty", J Arthroplasty, 18, pp.592~599 (2003)
- 이명철, "슬관절 재전치환술시 골 결손의 처치", 대한정형외과학회지, 37(2), pp.197~203 (2002), 대한정형외과학회
- Patel JV, "The fate of augments to treat type-2 bone defects in revision knee arthroplasty", J Bone Joint Surg Br, 86, pp.195~199 (2004)
- Stulberg SD, "Bone loss in revision total knee arthroplasty:graft options and adjuncts", J Arthroplasty, 18(3 Suppl 1), pp.48~50 (2003)
- Rand JA, "Modular augments in revision total knee arthroplasty", Orthop Clin North Am, 29, pp.347~353 (1998)
- Tsukada S, "Metal block augmentation for bone defects of the medial tibia during primary total knee arthroplasty", J Orthop Surg Res, 8, pp.36~ (2013)
- Haas SB, "Revision total knee arthroplasty with use of modular components with stems inserted without cement", J Bone Joint Surg Am, 77, pp.1700~1707 (1995)
- Guha AR, "Radiolucent lines below the tibial component of a total knee replacement(TKR) : a comparison between single-and two-stage cementation techniques", Int Orthop, 32, pp.453~457 (2008)
- Lohmann CH, "Metallic debris from metal-on-metal total hip arthroplasty regulates periprosthetic tissues", World J Orthop, 5, pp.660~666 (2014)
- Shannon BD, "Revision total knee arthroplasty with cemented components and uncemented intramedullary stems", J Arthroplasty, 18(7 Suppl 1) (2003)
- Kyoung-Jai Lee, "Minimum Two-year Results of Revision Total Knee Arthroplasty Following Infectious or Non-infectious Causes", Knee Surgery and Related Research, 24(4), pp.227~234 (2012), 대한슬관절학회