Measurement of Knee Rotation Angles Using a Smartphone Application: An Experimental Study of Porcine Knees
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: This study evaluated the efficacy of a smartphone application in the measurement of rotation angles in porcine knees. Materials and Methods: Two K-wires were fixated to the femoral condyle and anterior tibial crest of 10 porcine legs. The angle created between the K-wires with an external rotation force applied was measured on a photograph and defined as the true angle. The same force was applied to the legs placed on a splint with a smartphone attached to the plantar side. The angle presented on a smartphone application was determined as the measured angle. The differences between the true and measured angles in 30° and 90° knee flexion and differences in measured angles depending on the status of the popliteus tendon were compared. Results: In the intact knees, the mean true angles in 30° and 90° flexion were 20.5°±1.4° and 19.1°±1.3°, respectively, and the mean measured angles in 30° and 90° flexion were 21.1°±0.9° and 18.6°±1.6°, respectively. When the popliteus tendon was cut, the mean true angles in 30° and 90° flexion were 31.4°±1.1° and 38.5°±2.5°, respectively, and the mean measured angles in 30° and 90° flexion were 31.8°±1.2° and 39.2°±2.8°, respectively. The differences between the true and measured angles were not significant. The measured angle increased by more than 10° after cutting of the popliteus tendon in both 30° and 90° flexion. Conclusions: Using a smartphone application could be a good method of measuring knee rotation.
Abstract
Purpose: This study evaluated the efficacy of a smartphone application in the measurement of rotation angles in porcine knees. Materials and Methods: Two K-wires were fixated to the femoral condyle and anterior tibial crest of 10 porcine legs. The angle created between the K-wires with an external rotation force applied was measured on a photograph and defined as the true angle. The same force was applied to the legs placed on a splint with a smartphone attached to the plantar side. The angle presented on a smartphone application was determined as the measured angle. The differences between the true and measured angles in 30° and 90° knee flexion and differences in measured angles depending on the status of the popliteus tendon were compared. Results: In the intact knees, the mean true angles in 30° and 90° flexion were 20.5°±1.4° and 19.1°±1.3°, respectively, and the mean measured angles in 30° and 90° flexion were 21.1°±0.9° and 18.6°±1.6°, respectively. When the popliteus tendon was cut, the mean true angles in 30° and 90° flexion were 31.4°±1.1° and 38.5°±2.5°, respectively, and the mean measured angles in 30° and 90° flexion were 31.8°±1.2° and 39.2°±2.8°, respectively. The differences between the true and measured angles were not significant. The measured angle increased by more than 10° after cutting of the popliteus tendon in both 30° and 90° flexion. Conclusions: Using a smartphone application could be a good method of measuring knee rotation.
참고문헌 (17)
- 전윤상, "Mid-Term Outcomes of Anterior Cruciate Ligament Reconstruction with Far Anteromedial Portal Technique", Knee Surgery and Related Research, 29(1), pp.19~25 (2017), 대한슬관절학회
- Noyes FR, "Use of allografts after failed treatment of rupture of the anterior cruciate ligament", J Bone Joint Surg Am, 76, pp.1019~1031 (1994)
- Ruiz N, "The Comparative role of the anterior cruciate ligament and anterolateral structures in controlling passive internal rotation of the knee : a biomechanical study", Arthroscopy, 32, pp.1053~1062 (2016)
- Bleday RM, "Instrumented measurement of the posterolateral corner", Arthroscopy, 14, pp.489~494 (1998)
- Bae JH, "Evaluation of the reliability of the dial test for posterolateral rotatory instability : a cadaveric study using an isotonic rotation machine", Arthroscopy, 24, pp.593~598 (2008)
- Su X., "Activity recognition with smartphone sensors", Tsinghua Sci Technol, 19, pp.235~249 (2014)
- Terry GC, "The posterolateral aspect of the knee : anatomy and surgical approach", Am J Sports Med, 24, pp.732~739 (1996)
- Brinkman JM, "The insertion geometry of the posterolateral corner of the knee", J Bone Joint Surg Br, 87, pp.1364~1368 (2005)
- LaPrade RF, "The anatomy of the posterior aspect of the knee. An anatomic study", J Bone Joint Surg Am, 89, pp.758~764 (2007)
- Djian P., "Posterolateral knee reconstruction", Orthop Traumatol Surg Res, 101(1 Suppl), pp.S159~S170 (2015)
- Yoon KH, "Comparison of anatomic posterolateral knee reconstruction using 2 different popliteofibular ligament techniques", Am J Sports Med, 44, pp.916~921 (2016)
- Harner CD, "Biomechanical analysis of a posterior cruciate ligament reconstruction : deficiency of the posterolateral structures as a cause of graft failure", Am J Sports Med, 28, pp.32~39 (2000)
- LaPrade RF, "The effects of grade III posterolateral knee complex injuries on anterior cruciate ligament graft force : a biomechanical analysis", Am J Sports Med, 27, pp.469~475 (1999)
- Noyes FR, "Posterior subluxations of the medial and lateral tibiofemoral compartments : an in vitro ligament sectioning study in cadaveric knees", Am J Sports Med, 21, pp.407~414 (1993)
- Loomer RL, "A test for knee posterolateral rotatory instability", Clin Orthop Relat Res, (264), pp.235~238 (1991)
- Meyer RD, "Arthroscopy training using a"black box"technique", Arthroscopy, 9, pp.338~340 (1993)
- Voto SJ, "Arthroscopic training using pig knee joints", Clin Orthop Relat Res, (226), pp.134~137 (1988)