본문 바로가기
KERD
논문KCI 등재

Biomechanical effects of stitches on the intra-articular mid-substance of quadruple hamstring-tendon grafts for anterior cruciate ligament reconstruction – a pilot comparative cadaveric study

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Background: There is little data in the literature regarding the preparation methods of the intra-articular portion of quadruple hamstring-tendon grafts for anterior cruciate ligament (ACL) reconstruction. The aim of this study was to compare the biomechanical properties of a sutured transplant to that of a non-sutured transplant. The hypothesis was that adding stitches to the intra-articular portion of the graft increased its resistance. Method: A comparative cadaveric study was carried out on five pairs of knees. The average age of the cadavers was 68 years. The exclusion criterion was past knee surgery. In the Sutured Group (SG) two stitches were made on the grafts. No stitches were made on the grafts of the Non-sutured Group (NSG). A tensile failure test was carried out using an Instron® loading machine. The maximal load to failure and stiffness were recorded and we observed the mode of failure for each graft. Statistical analysis was performed using the Wilcoxon rank sum test. Level of significance was set at p < 0.05. Results: The hypothesis proposed was not confirmed; adding stitches to the intra-articular portion of the fourstrand hamstring-tendon graft does not increase its biomechanical properties. The maximal load to failure was 233.5 N ± 40.6 (186.7–274.5 N) for the NSG, 19.6% higher than for the SG which was 195.2 N ± 42.9 (139.0–238.2 N). Nevertheless, the difference observed was not statistically significant (p = 0.188). The stiffness of the grafts for the NSG was 23.5 N/mm ± 5.3 (17.8–29 N/mm) and 19.7 N/mm ± 5.5 (13.2–24.7 N/mm) for the SG grafts. Overall stiffness values for the NSG were 19% higher than those of the SG; however, the results were not statistically significant (p = 0.438). The failure mode was a rupture at the fixation point except for one sample from the SG which failed at an intra-articular stitch. Conclusion: Whilst the initial hypothesis was not verified, nevertheless, the maximal loads to failure and stiffness were approximately 20% higher when there were no intra-articular stitches compared to the situation where stitches were added to the intra-articular portion of the graft. This was a cadaveric pilot study and, therefore, whilst we are not able to extend our results to clinical practice, the outcomes would indicate the need for further development of this and related protocols deriving from the question of whether there is weakening the graft when adding stitches to its midsubstance. These results remain to be confirmed by further research.

Abstract

Background: There is little data in the literature regarding the preparation methods of the intra-articular portion of quadruple hamstring-tendon grafts for anterior cruciate ligament (ACL) reconstruction. The aim of this study was to compare the biomechanical properties of a sutured transplant to that of a non-sutured transplant. The hypothesis was that adding stitches to the intra-articular portion of the graft increased its resistance. Method: A comparative cadaveric study was carried out on five pairs of knees. The average age of the cadavers was 68 years. The exclusion criterion was past knee surgery. In the Sutured Group (SG) two stitches were made on the grafts. No stitches were made on the grafts of the Non-sutured Group (NSG). A tensile failure test was carried out using an Instron® loading machine. The maximal load to failure and stiffness were recorded and we observed the mode of failure for each graft. Statistical analysis was performed using the Wilcoxon rank sum test. Level of significance was set at p < 0.05. Results: The hypothesis proposed was not confirmed; adding stitches to the intra-articular portion of the fourstrand hamstring-tendon graft does not increase its biomechanical properties. The maximal load to failure was 233.5 N ± 40.6 (186.7–274.5 N) for the NSG, 19.6% higher than for the SG which was 195.2 N ± 42.9 (139.0–238.2 N). Nevertheless, the difference observed was not statistically significant (p = 0.188). The stiffness of the grafts for the NSG was 23.5 N/mm ± 5.3 (17.8–29 N/mm) and 19.7 N/mm ± 5.5 (13.2–24.7 N/mm) for the SG grafts. Overall stiffness values for the NSG were 19% higher than those of the SG; however, the results were not statistically significant (p = 0.438). The failure mode was a rupture at the fixation point except for one sample from the SG which failed at an intra-articular stitch. Conclusion: Whilst the initial hypothesis was not verified, nevertheless, the maximal loads to failure and stiffness were approximately 20% higher when there were no intra-articular stitches compared to the situation where stitches were added to the intra-articular portion of the graft. This was a cadaveric pilot study and, therefore, whilst we are not able to extend our results to clinical practice, the outcomes would indicate the need for further development of this and related protocols deriving from the question of whether there is weakening the graft when adding stitches to its midsubstance. These results remain to be confirmed by further research.

참고문헌 (18)

  1. Jenny JY, "L’Arthroscopie" (2015), Elsevier Masson
  2. Bonnin M, "The Knee Joint: Surgical Techniques and Strategies" (2012), Springer-Verlag;
  3. Hangody G, "Pitfalls during biomechanical testing-Evaluation of different fixation methods for measuring tendons endurance properties", Physiol Intern, 103(1), pp.86~93 (2016)
  4. Woo SL, "Effects of postmortem storage by freezing on ligament tensile behavior", J Biomech, 19(5), pp.399~404 (1986)
  5. Moon DK, "The effects of refreezing on the viscoelastic and tensile properties of ligaments", J Biomech, 39(6), pp.1153~1157 (2006)
  6. Bahlau D, "Mechanical advantage of preserving the hamstring tibial insertion for anterior cruciate ligament reconstruction-A cadaver study", Orthop Traumatol Surg Res, 105(1), pp.89~93 (2019)
  7. Cavaignac E, "Can the gracilis replace the anterior cruciate ligament in the knee? A biomechanical study", Int Orthop, 40(8), pp.1647~1653 (2016)
  8. Clavert P, "Effects of freezing", thawing on the biomechanical properties of human tendons, 2001, pp.23(4), 259~262
  9. Höher J, "Impact of tendon suturing on the interference fixation strength of quadrupled hamstring tendon grafts", Arch Orthop Trauma Surg, 133(9), pp.1309~1314 (2013)
  10. Millett P, "Effects of braiding on tensile properties of four-strand human hamstring tendon grafts", Am J Sports Med, 31, pp.714~717 (2003)
  11. van Eck CF, "Factors that influence the intra-articular rupture pattern of the ACL graft following single-bundle reconstruction", Knee Surg Sports Traumatol Arthrosc, 19(8), pp.1243~1248 (2011)
  12. Handl M, "Reconstruction of the anterior cruciate ligament : dynamic strain evaluation of the graft", Knee Surg Sports Traumatol Arthrosc, 15(3), pp.233~241 (2007)
  13. Noyes FR, "Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions", J Bone Joint Surg Am, 66(3), pp.344~352 (1984)
  14. Woo SL, "Mechanical properties of tendons and ligaments. I. Quasi-static and nonlinear viscoelastic properties", Biorheology, 19(3), pp.385~396 (1982)
  15. Pailhé R, "Biomechanical study of ACL reconstruction grafts", J Orthop Res, 33(8), pp.1188~1196 (2015)
  16. Shi D, "A novel, inexpensive and easy to use tendon clamp for in vitro biomechanical testing", Med Eng Phys, 34(4), pp.516~520 (2012)
  17. Sharkey NA, "Freeze clamping musculo-tendinous junctions for in vitro simulation of joint mechanics", J Biomech, 28(5), pp.631~635 (1995)
  18. Cheung JT-M, "A serrated jaw clamp for tendon gripping", Med Eng Phys, 28(4), pp.379~382 (2006)

관련 논문AI추천

Clinical experience with woven and parallel hamstring-tendon anterior cruciate ligament reconstructionDivyanshu Goyal, Sandeep Yadav, Vidyasagar JVS대한슬관절학회 · Knee Surgery and Related Research2019 · 제31권 Tibial-graft fixation methods on anterior cruciate ligament reconstructions: a literature reviewde Oliveira Gabriel Taniguti, Medeiros João Victor, Nicolini Alexandre Pedro, Nunes Gilvan Rodrigues Silva, Pereira Vitor Luis대한슬관절학회 · Knee Surgery and Related Research2021 · 제33권 Intraoperative Graft Isometry in Anatomic Single-­Bundle Anterior Cruciate Ligament Reconstruction유재두, Hyung Mook Lim, Joon Hee Cho, Sang Hoon Park, Sang Woo Kim, You Keun Kim대한슬관절학회 · Knee Surgery and Related Research2018 · 제30권 제2호Kinematic Analysis of Five Different Anterior Cruciate Ligament Reconstruction TechniquesAli Hosseini, Guoan Li, Hemanth R Gadikota, Peter Asnis대한슬관절학회 · Knee Surgery and Related Research2015 · 제27권 제2호Biomechanical comparison of single-bundle versus double-bundle anterior cruciate ligament reconstruction: a meta-analysis문동규, 유준일, 황선철, Cho Sung-Hee, Kim Kun-Tae, Oh Jin-Young, Park Young-Jin, Won Hee-Chan대한슬관절학회 · Knee Surgery and Related Research2020 · 제32권 Single-Bundle Anterior Cruciate Ligament Reconstruction with Semitendinosus Tendon Using the PINN-ACL CrossPin System: Minimum 4-Year Follow-up경희수, Byoung-Joo Lee, Chang-Hwa Lee, Seung-Gil Baek대한슬관절학회 · Knee Surgery and Related Research2015 · 제27권 제1호

이 간행물의 다른 논문 (63건)