본문 바로가기
KERD
논문KCI 등재

Verification of the applicability of the RAD7 radon monitor to the solid radon source exhalation reference model

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

The RAD7 radon monitor, based on the electrostatic collection method, is sensitive to humidity during measurements, necessitating the use of a desiccant to maintain the relative humidity in its built-in chamber less than 10 %. Therefore, the gas inside the radon accumulation chamber will also be dried in closed-loop measurement. In the previous study, a solid Rn-222 source exhalation reference model was proposed, which can adjust the radon exhalation rate by adjusting the radon accumulation chamber’s bottom area. In this paper, three sets of experiments were conducted to verify the applicability of RAD7 to this model. Results show that when the temperature is about 26 ◦C and the relative humidity inside the chamber is reduced from 71 % to 32 %, the average radon exhalation rate (43.8 ± 1.9 mBq m⁻2 s⁻1) aligns within one standard error of AlphaGUARD’s (41.0 ± 3.5 mBq m⁻2 s⁻1) and the reference value (43.0 ± 0.5 mBq m⁻2 s⁻1), indicating that drying has almost no effect on the experimental results. Therefore, the model is suitable for verifying the accuracy of radon exhalation rates measured by RAD7, and commercially available radon exhalation measuring instruments based on electrostatic collection methods can also be calibrated using this model.

Abstract

The RAD7 radon monitor, based on the electrostatic collection method, is sensitive to humidity during measurements, necessitating the use of a desiccant to maintain the relative humidity in its built-in chamber less than 10 %. Therefore, the gas inside the radon accumulation chamber will also be dried in closed-loop measurement. In the previous study, a solid Rn-222 source exhalation reference model was proposed, which can adjust the radon exhalation rate by adjusting the radon accumulation chamber’s bottom area. In this paper, three sets of experiments were conducted to verify the applicability of RAD7 to this model. Results show that when the temperature is about 26 ◦C and the relative humidity inside the chamber is reduced from 71 % to 32 %, the average radon exhalation rate (43.8 ± 1.9 mBq m⁻2 s⁻1) aligns within one standard error of AlphaGUARD’s (41.0 ± 3.5 mBq m⁻2 s⁻1) and the reference value (43.0 ± 0.5 mBq m⁻2 s⁻1), indicating that drying has almost no effect on the experimental results. Therefore, the model is suitable for verifying the accuracy of radon exhalation rates measured by RAD7, and commercially available radon exhalation measuring instruments based on electrostatic collection methods can also be calibrated using this model.

관련 논문AI추천

Research on the method to measure the average radon exhalation rate of room inner surfaceFan Zhongkai, Li Huiying, Lin Fen, Liu Jia, Liu Shuaibin, Liu Yi, Luo Cheng, Luo Shicheng, Mao Xianfa, Tan Yanliang, Xiao Feng, Xie Ruomei, Xu Hongbo, Yang Xinyue, You Hao, You Haoyu, Yuan Hongzhi, Zu Chenxi한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제5호Measurement of the radon and thoron exhalation rates from the water surface of Yixin lakeCheng Linquan, Fan Zhongkai, Hu Tao, Li Huiying, Lin Fen, Liu Shuaibin, Liu Zhipeng, Mo Yixiang, Sun Jiale, Tan Yanliang, Wu Jiulin, Xie Ruomei, Yi Haibo, Yuan Shuai한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제4호Simultaneous measurement of radon exhalation rate and CO2 flux based on accumulation chamber technique with a closed-loop systemLi Huiying, Liu Zhipeng, Luo Shicheng, Mao Xianfa, Sun Jiale, Tan Yanliang, Wu Jiulin, Xiao Feng, Xu Hongbo, Yang Xinyue, Yi Haibo, Yuan Hongzhi, Zu Chenxi한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제11호A preliminary study on real-time Rn/Tn discriminative detection using air-flow delay in two ion chambers in series김준혁, 박재현, 장호종, 조규성, das sopan한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제12호Assessment of soil gas radon migration and transport through the estimation of radon diffusion length and diffusion coefficient in the soil matrixJoshi Abhishek, Panwar Pooja, Prasad Mukesh, Ramola R.C., Sharma Navjeet, Singh Krishna Pal, Singh Prakhar한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제4호Radon an indoor risk: In the Urban Devarakonda, Telangana state, IndiaGopal Reddy Ch, Reddy P. Yadagiri, Sreenath Reddy M., Srinivas Reddy M., Suman G., Vinay Kumar Reddy K.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제2호

이 간행물의 다른 논문 (59건)