Measurement of the radon and thoron exhalation rates from the water surface of Yixin lake
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The importance of determining the radon exhalation rate from water surface is emphasized by the increased use of radon and its daughter products as tracers in large-scale circulation studies of the atmosphere. There were many methods to measure radon exhalation from water surface. With the development of radon exhalation rate measurement methods and instruments on the surface of the soil, the rock and building materials, so the radon exhalation rate from water surface can be more accurately measured by applying these improved methods and instruments. In this paper, a cuboid accumulation chamber surrounded by foam boards and a RAD7 were used to measure the radon exhalation rate on the water surface at three different positions by Yixin lake. Each measurement was performed 2 h. The radon exhalation rate from the water surface was about 6 × 10 3 Bq m 2s 1. The thoron exhalation rate from the water surface also can be estimated, it is about 0.16 Bq m 2s 1. These results hint that the radon transmission from the lake bottom soil to water and then into the atmosphere.
Abstract
The importance of determining the radon exhalation rate from water surface is emphasized by the increased use of radon and its daughter products as tracers in large-scale circulation studies of the atmosphere. There were many methods to measure radon exhalation from water surface. With the development of radon exhalation rate measurement methods and instruments on the surface of the soil, the rock and building materials, so the radon exhalation rate from water surface can be more accurately measured by applying these improved methods and instruments. In this paper, a cuboid accumulation chamber surrounded by foam boards and a RAD7 were used to measure the radon exhalation rate on the water surface at three different positions by Yixin lake. Each measurement was performed 2 h. The radon exhalation rate from the water surface was about 6 × 10 3 Bq m 2s 1. The thoron exhalation rate from the water surface also can be estimated, it is about 0.16 Bq m 2s 1. These results hint that the radon transmission from the lake bottom soil to water and then into the atmosphere.
참고문헌 (11)
- H. Liu, "Effects of radon exposure on gut microbiota and its metabolites short-chain fatty acids in mice", Toxicology, 486, pp.153449~ (2023)
- M. Hosoda, "Experimental system to evaluate the effective diffusion coefficient of radon", Rev. Sci. Instrum, 80(1), pp.013501~ (2009)
- M. Zimmer, "Continuous H2O, CO2, 222Rn and temperature measurements on merapi volcano, Indonesia", J. Volcanol. Geoth. Res, 125(1–2), pp.25~38 (2003)
- H. Woith, "Radon earthquake precursor : a short review", Eur. Phys. J. Spec. Top, 224(4), pp.611~627 (2015)
- V. Walia, "Continuous temporal soil-gas composition variations for earthquake precursory studies along Hsincheng and Hsinhua faults in Taiwan", Radiat. Meas, 44(9–10), pp.934~939 (2009)
- W. E. Clements, "Atmospheric pressure effects on 222Rn transport across the earth-air interface", J. Geophys. Res, 79(33), pp.5025~5029 (1974)
- F. Quattrocchi, "Test-sites for earthquake prediction experiments within the Colli Albani region", Phys. Chem. Earth, 23(9–10), pp.915~920 (1998)
- M. H. Wilkening, "Radon 222 from the ocean surface", J. Geophys. Res, 80(27), pp.3828~3830 (1975)
- Y. Tan, "Measuring radon exhalation rate through three cycles", J. Instrum, 7(8), pp.T08004~ (2012)
- S. Qiu, "First intercomparison of Tn–Rn discriminative measurements in China", Radiat. Protect. Dosim, 128(1), pp.124~127 (2008)
- Y. Tan, "Research on the lower detection efficiency of the RAD7 for 220Rn than for 222Rn", J. Instrum, 9(6), pp.T06001~ (2014)
