본문 바로가기
KERD
논문KCI 등재

Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose: We compared the mid-term results after total knee arthroplasty (TKA) using PFC Sigma RP-F mobile model with PFC Sigma PS fixed model. Materials and Methods: We analyzed 45 knees that underwent TKA with PFC Sigma RP-Fn (study group) and 45 knees with PFC Sigma PS (control group). The mean follow-up period was 65 months (range, 60-69 months). The evaluation system of the American knee society was used for clinical and radiological assessment. Also, the maximal knee flexion angle was assessed. Results: The mean maximum flexion angle in the study group (135^o) was greater than that in the control group (125^o) at the early post-operation & final follow-up period (p=0.033). The range of motion (ROM) in the study group was recovered earlier at the postoperative 6 months, and ROM gain was improved to a greater extent at the final follow-up period (p=0.039). The knee score and function score and radiographic evaluation were no difference between the two groups (p>0.05) at the final follow-up. The two cases of radiolucency in posterior condyle and medial tibial plateau and one case of patellar elongation were seen in the study group. Conclusions: The PFC Sigma RP-F mobile system appears to facilitate greater maximum flexion angle and ROM gain with two cases of radiolucent line.

Abstract

Purpose: We compared the mid-term results after total knee arthroplasty (TKA) using PFC Sigma RP-F mobile model with PFC Sigma PS fixed model. Materials and Methods: We analyzed 45 knees that underwent TKA with PFC Sigma RP-Fn (study group) and 45 knees with PFC Sigma PS (control group). The mean follow-up period was 65 months (range, 60-69 months). The evaluation system of the American knee society was used for clinical and radiological assessment. Also, the maximal knee flexion angle was assessed. Results: The mean maximum flexion angle in the study group (135^o) was greater than that in the control group (125^o) at the early post-operation & final follow-up period (p=0.033). The range of motion (ROM) in the study group was recovered earlier at the postoperative 6 months, and ROM gain was improved to a greater extent at the final follow-up period (p=0.039). The knee score and function score and radiographic evaluation were no difference between the two groups (p>0.05) at the final follow-up. The two cases of radiolucency in posterior condyle and medial tibial plateau and one case of patellar elongation were seen in the study group. Conclusions: The PFC Sigma RP-F mobile system appears to facilitate greater maximum flexion angle and ROM gain with two cases of radiolucent line.

참고문헌 (26)

  1. Yamazaki J, "Hy-Flex II total knee system and range of motion", Arch Orthop Trauma Surg, 122, pp.156~160 (2002)
  2. Dennis DA, "Factors affecting flexion after total knee arthroplasty", Clin Orthop Relat Res, 464, pp.53~60 (2007)
  3. Harvey IA, "Factors affecting the range of movement of total knee arthroplasty", J Bone Joint Surg Br, 75, pp.950~955 (1993)
  4. Gupta SK, "The P.F.C. sigma RP-F TKA designed for improved performance: a matched-pair study", Orthopedics, 29, pp.S49~S52 (2006)
  5. Jones RE, "High-flexion rotating-platform knees: rationale, design, and patient selection", Orthopedics, 29, pp.S76~S79 (2006)
  6. Ranawat AS, "The P.F.C. sigma RP-F total knee arthroplasty: designed for improved performance", Orthopedics, 29, pp.S28~S29 (2006)
  7. Han HS, "High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement", J Bone Joint Surg Br, 89, pp.1457~1461 (2007)
  8. Cho SD, "Three- to six-year follow-up results after high-flexion total knee arthroplasty: can we allow passive deep knee bending?", Knee Surg Sports Traumatol Arthrosc, 19, pp.899~903 (2011)
  9. Bennett D, "Measurement of knee joint motion using digital imaging", Int Orthop, 33, pp.1627~1631 (2009)
  10. Insall JN, "Rationale of the Knee Society clinical rating system", Clin Orthop Relat Res, (248), pp.13~14 (1989)
  11. Ewald FC, "The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system", Clin Orthop Relat Res, (248), pp.9~12 (1989)
  12. Li G, "Biomechanics of posterior-substituting total knee arthroplasty: an in vitro study", Clin Orthop Relat Res, (404), pp.214~225 (2002)
  13. Hendel D, "Fracture of the central polyethylene tibial spine in posterior stabilized total knee arthroplasty", J Arthroplasty, 18, pp.672~674 (2003)
  14. Bin SI, "Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery", Knee Surg Sports Traumatol Arthrosc, 15, pp.350~355 (2007)
  15. Maniar RN, "Postoperative flexion analysis of 3 rotating-platform knee designs", Orthopedics, 35, pp.e1159~e1165 (2012)
  16. Massin P, "Does hyperflex total knee design improve postoperative active flexion?", Orthop Traumatol Surg Res, 96, pp.376~380 (2010)
  17. Nutton RW, "Does a mobile-bearing, high-flexion design increase knee flexion after total knee replacement?", J Bone Joint Surg Br, 94, pp.1051~1057 (2012)
  18. 서정탁, "PFC Sigma RP-FⓇ를 이용한 슬관절 전치환술 -2년 단기 추시결과-", 대한정형외과학회지, 43(1), pp.57~64 (2008), 대한정형외과학회
  19. Maniar RN, "High-flex rotating platform knee implants: two- to 6-year results of a prospective study", J Arthroplasty, 27, pp.598~603 (2012)
  20. 김준식, "Range of motion of standard and high-flexion posterior stabilized total knee prostheses", JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 87A, pp.1470~1475, JOURNAL BONE JOINT SURGERY INC
  21. Aglietti P, "Comparison of mobile-bearing and fixed-bearing total knee arthroplasty: a prospective randomized study", J Arthroplasty, 20, pp.145~153 (2005)
  22. Ranawat AS, "Comparison of the PFC Sigma fixed-bearing and rotating-platform total knee arthroplasty in the same patient: short-term results", J Arthroplasty, 19, pp.35~39 (2004)
  23. Woolson ST, "Mobile- vs. fixed-bearing total knee arthroplasty: a clinical and radiologic study", J Arthroplasty, 19, pp.135~140 (2004)
  24. Taewan Kim, "Comparison of Mobile-Bearing and Fixed-Bearing Designs in High Flexion Total Knee Arthroplasty: Using a Navigation System", Knee Surgery and Related Research, 24(1), pp.25~33 (2012), 대한슬관절학회
  25. 서정탁, "고도굴곡형 슬관절 인공관절 전치환술에서가동형과 고정형 삽입물의 비교", Knee Surgery and Related Research, 22(3), pp.165~174 (2010), 대한슬관절학회
  26. Massin P, "Total knee arthroplasty with limitations of flexion", Orthop Traumatol Surg Res, 95, pp.S1~S6 (2009)

관련 논문AI추천

Comparison of Clinical Results and Risk of Patellar Injury between Attune and PFC Sigma Knee Systems송상준, Cheol Hee Park, Dae Kyung Bae, Se Gu Kang대한슬관절학회 · Knee Surgery and Related Research2018 · 제30권 제4호A Comparison of the Clinical and Radiographic Results of Press Fit Condylar Rotating-Platform High-Flexion and Low Contact Stress Mobile Bearing Prosthesis in Total Knee Arthroplasty: Short term Results이범구, 이용석, Ji Hoon Kwak, Nam Ki Kim, Shin Woo Nam대한슬관절학회 · Knee Surgery and Related Research2012 · 제24권 제1호Comparison of Mobile-Bearing and Fixed-Bearing Designs in High Flexion Total Knee Arthroplasty: Using a Navigation System서정탁, Shi Hwan Park, Taewan Kim대한슬관절학회 · Knee Surgery and Related Research2012 · 제24권 제1호Short-Term Results of Total Knee Arthroplasty with Anterior-Posterior Glide LCS Mobile-Bearing System왕립, 김경택, 박진우, 상민수, 임영훈대한슬관절학회 · Knee Surgery and Related Research2014 · 제26권 제3호Outcomes of the Different Types of Total Knee Arthroplasty with the Identical Femoral Geometry성상철, 이명철, 이상훈, 최원철, Sang Min Lee대한슬관절학회 · Knee Surgery and Related Research2012 · 제24권 제4호Evaluation of Postoperative Range of Motion and Functional Outcomes after Cruciate-Retaining and Posterior-Stabilized High-Flexion Total Knee Arthroplasty박관규, 양익환, 이우석, 한창동, 한창욱연세대학교의과대학 · Yonsei Medical Journal2012 · 제53권 제4호

이 간행물의 다른 논문 (10건)