Mid-term Results of Single-Radius Cruciate Retaining Total Knee Arthroplasty: Minimum 5 Year Follow-up
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: The single-radius design of the knee implant was introduced to improve the results of total knee arthroplasty (TKA) by reducing maximum extensor forces, and it also represents more physiologic quadriceps force pattern, which could have a positive effect on knee function after TKA. We studied mid-term results of single-radius designed cruciate retaining (CR) TKA.Materials and Methods: We analyzed the functional improvement and radiological osteolytic pattern after TKA using the single-radius Scorpio CR prosthesis. TKA was performed on 102 knees. The mean follow-up period was 73.8 months. For clinical assessment, the range of motion (ROM), Harris hip score, and functional outcome score were obtained preoperatively and at last follow-up.Results: The average ROM was 100.2o preoperatively and 121.7o at last follow-up. The average knee score was 59.2 points preoperatively and 92.9 points at last follow-up. The average functional outcome score was improved from 51.9 points preoperatively to 85.4 points at last follow-up. Radiolucency was observed in four knees but all were non-progressive lesions smaller than 2 mm.Conclusions: The clinical outcome of TKA using the single-radius CR prosthesis was good during the mid-term follow-up and the incidence of osteolysis was very rare.
Abstract
Purpose: The single-radius design of the knee implant was introduced to improve the results of total knee arthroplasty (TKA) by reducing maximum extensor forces, and it also represents more physiologic quadriceps force pattern, which could have a positive effect on knee function after TKA. We studied mid-term results of single-radius designed cruciate retaining (CR) TKA.Materials and Methods: We analyzed the functional improvement and radiological osteolytic pattern after TKA using the single-radius Scorpio CR prosthesis. TKA was performed on 102 knees. The mean follow-up period was 73.8 months. For clinical assessment, the range of motion (ROM), Harris hip score, and functional outcome score were obtained preoperatively and at last follow-up.Results: The average ROM was 100.2o preoperatively and 121.7o at last follow-up. The average knee score was 59.2 points preoperatively and 92.9 points at last follow-up. The average functional outcome score was improved from 51.9 points preoperatively to 85.4 points at last follow-up. Radiolucency was observed in four knees but all were non-progressive lesions smaller than 2 mm.Conclusions: The clinical outcome of TKA using the single-radius CR prosthesis was good during the mid-term follow-up and the incidence of osteolysis was very rare.
참고문헌 (26)
- Churchill DL, "The transepicondylar axis approximates the optimal flexion axis of the knee", Clin Orthop Relat Res, 356, pp.111~118 (1998)
- Hollister AM, "The axes of rotation of the knee", Clin Orthop Relat Res, 290, pp.259~268 (1993)
- D’Lima DD, "Quadriceps moment arm and quadriceps forces after total knee arthroplasty", Clin Orthop Relat Res, 392, pp.213~220 (2001)
- Barrack RL, "Patellar resurfacing in total knee arthroplasty", J Am Acad Orthop Surg, 8, pp.75~82 (2000)
- Healy WL, "Patellofemoral complications following total knee arthroplasty : correlation with implant design and patient risk factors", J Arthroplasty, 10, pp.197~201 (1995)
- Abbas D, "Medium-term results of the Scorpio total knee replacement", Knee, 13, pp.307~311 (2006)
- Kolisek FR, "Scorpio posterior-stabilized knee system : 5-year clinical and functional results", J Arthroplasty, 21, pp.1187~1192 (2006)
- Mahoney OM, "5-to 9-year survivorship of single-radius, posterior-stabilized TKA", Clin Orthop Relat Res, 466, pp.436~442 (2008)
- Outerbridge RE, "The etiology of chondromalacia patellae: 1961", Clin Orthop Relat Res, 389, pp.5~8 (2001)
- Scott WN, "Insall & Scott Surgery of the Knee", pp.p1071~p1072 (2012), Elsevier, Churchill & Winston
- Insall JN, "Rationale of the Knee Society clinical rating system", Clin Orthop Relat Res, 248, pp.13~14 (1989)
- Ewald FC, "The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system", Clin Orthop Relat Res, 248, pp.9~12 (1989)
- Kaplan EL, "Nonparametric estimation from incomplete observations", Am Stat Assoc, 53, pp.457~481 (1958)
- Wang H, "A biomechanical comparison between the single-axis and multi-axis total knee arthroplasty systems for the stand-to-sit movement", Clin Biomech(Bristol, Avon), 20, pp.428~433 (2005)
- Greene KA, "Quadriceps muscle function in primary total knee arthroplasty", J Arthroplasty, 23(7 Suppl), pp.15~19 (2008)
- Poss R, "Factors influencing the incidence and outcome of infection following total joint arthroplasty", Clin Orthop Relat Res, 182, pp.117~126 (1984)
- Ranawat CS, "Effect of posterior cruciate sacrificing on durability of the cement-bone interface: a nine-year survivorship study of 100 total condylar knee arthroplasties", Clin Exp Rheumatol, 7(Suppl 3), pp.S149~S152 (1989)
- Puloski SK, "Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris", J Bone Joint Surg Am, 83, pp.390~397 (2001)
- Wasielewski RC, "Tibial insert undersurface as a contributing source of polyethylene wear debris", Clin Orthop Relat Res, 345, pp.53~59 (1997)
- Becker MW, "Bilateral total knee arthroplasty: one cruciate retaining and one cruciate substituting", Clin Orthop Relat Res, 271, pp.122~124 (1991)
- Dennis DA, "Range of motion after total knee arthroplasty: the effect of implant design and weight-bearing conditions", J Arthroplasty, 13, pp.748~752 (1998)
- Dorr LD, "Functional comparison of posterior cruciate-retained versus cruciate-sacrificed total knee arthroplasty", Clin Orthop Relat Res, 236, pp.36~43 (1988)
- Andriacchi TP, "Retention of the posterior cruciate in total knee arthroplasty", J Arthroplasty, 3(Suppl), pp.S13~S19 (1988)
- Scott RD, "Twelve years’ experience with posterior cruciate-retaining total knee arthroplasty", Clin Orthop Relat Res, 205, pp.100~107 (1986)
- Sorger JI, "The posterior cruciate ligament in total knee arthroplasty", J Arthroplasty, 12, pp.869~879 (1997)
- Hall J, "Extensor mechanism function in single-radius vs multiradius femoral components for total knee arthroplasty", J Arthroplasty, 23, pp.216~219 (2008)
