Results of Gender-Specific Total Knee Arthroplasty: Comparative Study with Traditional Implant in Female Patients
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Purpose: To compare the incidence of overhang between two distinct femoral components and whether there is clinical and radiological benefit of gender-specific implants in short-term follow-up. Materials and Methods: One hundred and four knees in consecutive 66 female patients who underwent primary total knee arthroplasty due to primary osteoarthritis were included in this study. Overhang was measured and recorded in every cut surface of femur with both gender-specific and traditional trial femoral components respectively in every patient. Then, the knees were divided into two groups according to the type of the permanent femoral component they received. Clinical and radiological outcomes were compared between 2 groups at minimum 3 years after operation. Results: Mean follow-up duration was 41.3 months (range, 36 to 50 months). Sixty two knees (59.6%) showed femoral overhang at least in one area with a traditional trial component, while 26 knees (25.0%) did with a gender-specific trial component (p<0.001). In terms of range of motion, Hospital for Special Surgery knee score, radiographic result, patella tilt angle and displacement, no significant difference was observed between two groups. Conclusions: The use of gender-specific implants substantially reduced the incidence of femoral overhang but did not demonstrate any clinical, functional or radiologic benefit in short-term follow-up.
Abstract
Purpose: To compare the incidence of overhang between two distinct femoral components and whether there is clinical and radiological benefit of gender-specific implants in short-term follow-up. Materials and Methods: One hundred and four knees in consecutive 66 female patients who underwent primary total knee arthroplasty due to primary osteoarthritis were included in this study. Overhang was measured and recorded in every cut surface of femur with both gender-specific and traditional trial femoral components respectively in every patient. Then, the knees were divided into two groups according to the type of the permanent femoral component they received. Clinical and radiological outcomes were compared between 2 groups at minimum 3 years after operation. Results: Mean follow-up duration was 41.3 months (range, 36 to 50 months). Sixty two knees (59.6%) showed femoral overhang at least in one area with a traditional trial component, while 26 knees (25.0%) did with a gender-specific trial component (p<0.001). In terms of range of motion, Hospital for Special Surgery knee score, radiographic result, patella tilt angle and displacement, no significant difference was observed between two groups. Conclusions: The use of gender-specific implants substantially reduced the incidence of femoral overhang but did not demonstrate any clinical, functional or radiologic benefit in short-term follow-up.
참고문헌 (16)
- Chin KR, "Intraoperative measurements of male and female distal femurs during primary total knee arthroplasty", J Knee Surg, 15, pp.213~217 (2002)
- Hitt K, "Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems", J Bone Joint Surg Am, 85(Suppl 4), pp.115~122 (2003)
- Kwak DS, "Morphometry of the proximal tibia to design the tibial component of total knee arthroplasty for the Korean population", Knee, 14, pp.295~300 (2007)
- Poilvache PL, "Rotational landmarks and sizing of the distal femur in total knee arthroplasty", Clin Orthop Relat Res, (331), pp.35~46 (1996)
- Vaidya SV, "Anthropometric measurements to design total knee prostheses for the Indian population", J Arthroplasty, 15, pp.79~85 (2000)
- Conley S, "The female knee: anatomic variations", J Am Acad Orthop Surg, 15(Suppl 1), pp.S31~S36 (2007)
- Merchant AC, "The female knee : anatomic variations and the female-specific total knee design", Clin Orthop Relat Res, 466, pp.3059~3065 (2008)
- Insall JN, "A comparison of four models of total knee-replacement prostheses", J Bone Joint Surg Am, 58, pp.754~765 (1976)
- Ewald FC, "The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system", Clin Orthop Relat Res, (248), pp.9~12 (1989)
- Gomes LS, "Patellar prosthesis positioning in total knee arthroplasty: a roentgenographic study", Clin Orthop Relat Res, (236), pp.72~81 (1988)
- Greene KA, "Gender-specific design in total knee arthroplasty", J Arthroplasty, 22(7 Suppl 3), pp.27~31 (2007)
- Song EK, "Comparison of outcomes after bilateral simultaneous total knee arthroplasty using gender-specific and unisex knees", J Arthroplasty, 27, pp.226~231 (2012)
- Guy SP, "Gender differences in distal femoral morphology and the role of gender specific implants in total knee replacement : a prospective clinical study", Knee, 19, pp.28~31 (2012)
- Tanavalee A, "The early results of gender-specific total knee arthroplasty in Thai patients", Knee, 18, pp.483~487 (2011)
- Clarke HD, "Restoration of femoral anatomy in TKA with unisex and gender-specific components", Clin Orthop Relat Res, 466, pp.2711~2716 (2008)
- Brown TE, "Component size asymmetry in bilateral total knee arthroplasty", Am J Knee Surg, 14, pp.81~84 (2001)