초록

This study addresses the need for realistic substitute materials in pediatric head CT to enhance imaging safety. Epoxy resin-based composites were developed to mimic cranial bone, brain tissue, cerebrospinal fluid and eye lens. Radiological properties were validated using Monte Carlo simulations and XMuDat software, with CT numbers measured on a 64-detector CT scanner at 80, 100, and 120 kVp. A comparison was applied against standard tissues from the International Commission on Radiation Units and Measurements (ICRU). For cranial bone, a composite of 70 % epoxy resin and 30 % calcium carbonate achieved a density of 1.65 g/cm³ and Zeff = 11.02, with deviations in mass attenuation coefficients from ICRU standard ranging from 17.4 % at 40 keV to 1.2 % at 150 keV. Brain matter (95 % resin, 5 % acetone) achieved Zeff = 6.19, with deviations from the ICRU standard ranging from 13.7 % to 5.5 %. CSF (80 % resin, 15 % silica, 5 % acetone) closely matched water, with deviations from the water standard ranging from 3.4 % to 1.1 %. Eye lens (95 % resin, 5 % sodium bicarbonate) achieved Zeff = 6.47, with deviations from ICRU standard ranging from 7.5 % to 4.2 %. These results demonstrate the potential of epoxy resin-based substitutes to approximate ICRU standard tissues supporting safer pediatric radiology protocols customized to this sensitive population.

Abstract

This study addresses the need for realistic substitute materials in pediatric head CT to enhance imaging safety. Epoxy resin-based composites were developed to mimic cranial bone, brain tissue, cerebrospinal fluid and eye lens. Radiological properties were validated using Monte Carlo simulations and XMuDat software, with CT numbers measured on a 64-detector CT scanner at 80, 100, and 120 kVp. A comparison was applied against standard tissues from the International Commission on Radiation Units and Measurements (ICRU). For cranial bone, a composite of 70 % epoxy resin and 30 % calcium carbonate achieved a density of 1.65 g/cm³ and Zeff = 11.02, with deviations in mass attenuation coefficients from ICRU standard ranging from 17.4 % at 40 keV to 1.2 % at 150 keV. Brain matter (95 % resin, 5 % acetone) achieved Zeff = 6.19, with deviations from the ICRU standard ranging from 13.7 % to 5.5 %. CSF (80 % resin, 15 % silica, 5 % acetone) closely matched water, with deviations from the water standard ranging from 3.4 % to 1.1 %. Eye lens (95 % resin, 5 % sodium bicarbonate) achieved Zeff = 6.47, with deviations from ICRU standard ranging from 7.5 % to 4.2 %. These results demonstrate the potential of epoxy resin-based substitutes to approximate ICRU standard tissues supporting safer pediatric radiology protocols customized to this sensitive population.

관련 논문AI추천

Evaluating polyester resin as a viable substitute for PMMA in computed tomography dosimetry phantomsEl rhazouani O., Halimi A., Khallouqi A.한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제9호Evaluating backscatter factor variations in diagnostic radiology using different phantom materialsEl rhazouani O., Halimi A., Khallouqi A., Madkouri Y., Sekkat H.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제8호Radiation properties and dosimetric insights of Nylon CT phantoms: Advanced computational analysis using Phy-X, XCOM, and GATE/GEANT4El rhazouani O., Halimi A., Khallouqi A., Sekkat H.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제12호Dose coefficients for the ICRP pediatric mesh-type reference computational phantoms under idealized external photon exposure geometries김찬형, 신방호, 염연수, 최찬수, Bolch Wesley E.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제9호Evaluating the Kerma coefficients relevant to various water-equivalent materials at different photon energiesAbdi Zahra, Baghani Hamid Reza, Shamsabadi Reza한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제2호Investigation of radiological properties and water equivalence of polymer gel dosimeters in the energy range 0.1–10 keVBüyükyıldız Mehmet, Kaur Parminder, Levet Aytaç, Parsaei Sara, Rafiei Mustafa Mohammad, Thakur Sonika한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제6호

이 간행물의 다른 논문 (59건)