Radiofrequency cavities are crucial components in synchrotron light sources, providing beam energy replenishment and accelerating voltage. TM020 mode cavities offer superior performance compared to conventional TM010 cavities, exhibiting a higher quality factor and accelerating gradient. Their unique electromagnetic field distribution enables effective suppression of both higher and lower order modes via strategically placed dampers at the radial magnetic or electric field wave nodes. However, the sensitivity to misalignment is heightened near these nodes, where the magnetic or electric field gradient is maximized. Consequently, even minor deviations in coupling slot or wave node positioning can induce substantial electromagnetic field leakage, limiting the achievable accelerating voltage due to finite damper power handling. We present a novel leakage suppression scheme employing a Sector waveguide for precise control of coupling slot placement and a waveguide-to-coaxial input coupler to minimize azimuthal perturbations, thus stabilizing the field wave node. This approach drastically reduces accelerating field leakage, enabling stable operation of TM020 damped cavities at high accelerating gradients. Simulations of a 500 MHz TM020 cavity demonstrate leakage reduction to below 1% under operational conditions

Abstract

Radiofrequency cavities are crucial components in synchrotron light sources, providing beam energy replenishment and accelerating voltage. TM020 mode cavities offer superior performance compared to conventional TM010 cavities, exhibiting a higher quality factor and accelerating gradient. Their unique electromagnetic field distribution enables effective suppression of both higher and lower order modes via strategically placed dampers at the radial magnetic or electric field wave nodes. However, the sensitivity to misalignment is heightened near these nodes, where the magnetic or electric field gradient is maximized. Consequently, even minor deviations in coupling slot or wave node positioning can induce substantial electromagnetic field leakage, limiting the achievable accelerating voltage due to finite damper power handling. We present a novel leakage suppression scheme employing a Sector waveguide for precise control of coupling slot placement and a waveguide-to-coaxial input coupler to minimize azimuthal perturbations, thus stabilizing the field wave node. This approach drastically reduces accelerating field leakage, enabling stable operation of TM020 damped cavities at high accelerating gradients. Simulations of a 500 MHz TM020 cavity demonstrate leakage reduction to below 1% under operational conditions

관련 논문AI추천

Electromagnetic field compensation to attenuate energy leakage in TM020 mode damped cavityHao Xuerui, Li Zhongquan, Yang Lei, Yang Xue, Ye Kuangkuang, Zhang Yao, Zhou Xirui한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제3호Design of the 500 MHz 2-cell superconducting cavity for the SILFGe Yulin, Lu Liang, Ma Wei, Sun Yanbing, Yang Zhen, Yuan Nan, Zou Liping한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제12호Design and simulation of 500 MHz single cell superconducting RF cavity for SILFGe Yulin, Lu Liang, Ma Wei, Sun Yanbing, Yang Zhen, Yuan Nan, Zou Liping한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제1호High-power performance studies of an S-band high-gradient accelerating cavity for medical applicationsBlanch C., Boronat M., Esperante D., Fernández J., Fuster J., Fuster-Martínez N., Gimeno B., González-Iglesias D., Grudiev A., Lasheras N. Catalan, Martínez E., Martinez-Reviriego P., Martín-Luna P., Menendez A., Pedraza L., Wuensch W.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제1호Conceptual RF design of 750 MHz IH cavities for β  = 0.10–0.15 ion beams in medical acceleratorsAlvarado María, Calvo Pedro, Carmona José Miguel, Gavela Daniel, Giner Navarro Jorge, León Miguel, López Ricardo, Moreno Gabriela, Oliver Concepción, Rodríguez Ángel한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제9호Low beta superconducting cavity system design for HIAF iLinacBai Feng, Guo Hao, He Yuan, Huang Qitong, Huang Shichun, Jiang Tiancai, Liang Zehua, Li Chunlong, Liu Lubei, Liu Tong, Li Xiaoli, Tao Yue, Wang Fengfeng, Wang Zhijun, Xu Mengxin, Xu Xianbo, Yang Jiancheng, Zaplatin Evgeny, Zhang Shenghu, Zhang Shengxue한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제7호

이 간행물의 다른 논문 (59건)