본문 바로가기
KERD
논문KCI 등재

Polarization Behavior and Corrosion Inhibition of Copper in Acidic Chloride Solution Containing Benzotriazole

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류금속공학

초록

Polarization behavior and corrosion inhibition of copper in acidic chloride solutions containing benzotriazole were studied. Pourbaix diagrams constructed for copper in NaCl solutions with different BTAH concentrations were used to understand the polarization behavior. Open circuit potential (OCP) depended not only on chloride concentration, but also on whether a CuBTA layer was formed on the copper surface. Only when the (pH, OCP) was located well in the CuBTA region of the Pourbaix diagram, a stable corrosion inhibiting CuBTA layer was formed, which was confirmed by X-ray Photoelectron Spectroscopy (XPS) and a long-term corrosion test. The OCP for the CuBTA layer decreased logarithmically with increasing [Cl-] activity in the solution. A minimum BTAH concentration required to form a CuBTA layer for a given NaCl concentration and pH were determined from the Pourbaix diagram. It was found that 320 ppm BTAH solution could be used to form a corrosion-inhibiting CuBTA layer inside the corrosion pit in the sprinkler copper tube, successfully reducing water leakage rate of copper tubes. These experimental results could be used to estimate water chemistry inside a corrosion pit.

Abstract

Polarization behavior and corrosion inhibition of copper in acidic chloride solutions containing benzotriazole were studied. Pourbaix diagrams constructed for copper in NaCl solutions with different BTAH concentrations were used to understand the polarization behavior. Open circuit potential (OCP) depended not only on chloride concentration, but also on whether a CuBTA layer was formed on the copper surface. Only when the (pH, OCP) was located well in the CuBTA region of the Pourbaix diagram, a stable corrosion inhibiting CuBTA layer was formed, which was confirmed by X-ray Photoelectron Spectroscopy (XPS) and a long-term corrosion test. The OCP for the CuBTA layer decreased logarithmically with increasing [Cl-] activity in the solution. A minimum BTAH concentration required to form a CuBTA layer for a given NaCl concentration and pH were determined from the Pourbaix diagram. It was found that 320 ppm BTAH solution could be used to form a corrosion-inhibiting CuBTA layer inside the corrosion pit in the sprinkler copper tube, successfully reducing water leakage rate of copper tubes. These experimental results could be used to estimate water chemistry inside a corrosion pit.

참고문헌 (28)

  1. H. P. Lee, "Kinetics and Mechanisms of Cu Electrodissolution in Chloride Media", Journal of The Electrochemical Society, 133(10), pp.2035~2043 (1986), The Electrochemical Society[DOI]
  2. A. L. Bacarella, "The Anodic Dissolution of Copper in Flowing Sodium Chloride Solutions Between 25° and 175°C", Journal of The Electrochemical Society, 120(4), pp.459~ (1973), The Electrochemical Society[DOI]
  3. H. Cong, "Effect of Chlorine Concentration on Natural Pitting of Copper as a Function of Water Chemistry", Journal of The Electrochemical Society, 157, pp.C200~ (2010)[DOI]
  4. Jason C. Rushing, "Effect of aluminium solids and chlorine on cold water pitting of copper", Corrosion Science, 46(12), pp.3069~3088 (2004), Elsevier BV[DOI]
  5. Hongbo Cong, "Passivity and Pit Stability Behavior of Copper as a Function of Selected Water Chemistry Variables", Journal of The Electrochemical Society, 156(1), pp.C16~ (2009), The Electrochemical Society[DOI]
  6. Darren A. Lytle, "Pitting corrosion of copper in waters with high pH and low alkalinity", Journal AWWA, 100(3), pp.115~129 (2008), Wiley[DOI]
  7. Darren A. Lytle, "A comprehensive investigation of copper pitting corrosion in a drinking water distribution system", Corrosion Science, 52(6), pp.1927~1938 (2010), Elsevier BV[DOI]
  8. "Pitting corrosion of copper An equilibrium — mass transport study" (2002)[URL]
  9. Pitting corrosion of copper Further model studies, "Claes Taxén", ~ (2002)
  10. 조상원, "Stress Corrosion Cracking of Heat Exchanger Tubes in District Heating System", CORROSION SCIENCE AND TECHNOLOGY, 18(2), pp.49~54 (2019), 한국부식방식학회
  11. Yun-Ho Lee, "Effect of Benzotriazole on the Localized Corrosion of Copper Covered with Carbonaceous Residue", Materials, 14(11), pp.2722~ (2021), MDPI AG[DOI]
  12. FLORIAN MANSFELD, "Benzotriazole as Corrosion Inhibitor for Copper", CORROSION, 27(7), pp.289~294 (1971), Association for Materials Protection and Performance (AMPP)[DOI]
  13. V. Brusic, "Copper Corrosion With and Without Inhibitors", Journal of The Electrochemical Society, 138(8), pp.2253~2259 (1991), The Electrochemical Society[DOI]
  14. M. R. Vogt, "In Situ STM Study of (100) Cu Electrodes in Sulfuric Acid Solution in the Presence of Benzotriazole: Adsorption, Cu Corrosion, and Cu Deposition", Journal of The Electrochemical Society, 144(5), pp.L113~L116 (1997), The Electrochemical Society[DOI]
  15. G.W. Poling, "Reflection infra-red studies of films formed by benzotriazole on Cu", Corrosion Science, 10(5), pp.359~370 (1970), Elsevier BV[DOI]
  16. R. WALKER, "Triazole, Benzotriazole and Naphthotriazole as Corrosion Inhibitors for Copper", CORROSION, 31(3), pp.97~100 (1975), Association for Materials Protection and Performance (AMPP)[DOI]
  17. Tadeja Kosec, "Benzotriazole as an inhibitor of brass corrosion in chloride solution", Applied Surface Science, 253(22), pp.8863~8873 (2007), Elsevier BV[DOI]
  18. Desmond Tromans, "Anodic Polarization Behavior of Copper in Aqueous Chloride", Benzotriazole Solutions, 1991, pp.138(11), 3235~3244[DOI]
  19. R. Walker, "Benzotriazole as a Corrosion Inhibitor for Immersed Copper", CORROSION, 29(7), pp.290~298 (1973), Association for Materials Protection and Performance (AMPP)[DOI]
  20. 서상희, "Use of Hydrazine for Pitting Corrosion Inhibition of Copper Sprinkler Tubes:Reaction of Hydrazine with Corrosion By-Products", CORROSION SCIENCE AND TECHNOLOGY, 16(5), pp.247~256 (2017), 한국부식방식학회[DOI]
  21. 서상희, "아황산나트륨을 이용한 스프링클러 동배관 공식 부식 방지", CORROSION SCIENCE AND TECHNOLOGY, 16(5), pp.265~272 (2017), 한국부식방식학회[DOI]
  22. Thuy Duong Nguyen, "Synthesis and Characterization of Hydrotalcite", Graphene Oxide Containing Benzoate for Corrosion Protection of Carbon Steel, 2020, pp.19(2), 82~88[DOI]
  23. Desmond Tromans, "Aqueous Potential‐pH Equilibria in Copper‐Benzotriazole Systems", Journal of The Electrochemical Society, 145(3), pp.L42~L45 (1998), The Electrochemical Society[DOI]
  24. U. Bertocci, "Standard Potentials in Aqueous Solution" (2017), Routledge
  25. D. R. Lide, "Handbook of Chemistry and Physics" (2003), CRC Press
  26. Jian-Lin Yao, "Negative role of triphenylphosphine in the inhibition of benzotriazole at the Cu surface studied by surface-enhanced Raman spectroscopy", Journal of Electroanalytical Chemistry, 573(2), pp.255~261 (2004), Elsevier BV[DOI]
  27. B.V. Appa Rao, "X-ray photoelectron spectroscopy depth-profiling analysis of surface films formed on Cu–Ni (90", 10) alloy in seawater in the absence and presence of 1,2,3-benzotriazole, 2014, pp.556, 337~344[DOI]
  28. Tadeja Kosec, "Impedance and XPS study of benzotriazole films formed on copper, copper–zinc alloys and zinc in chloride solution", Corrosion Science, 50(7), pp.1987~1997 (2008), Elsevier BV[DOI]

관련 논문AI추천