대기 중 다환방향족탄화수소 측정방법의 성능평가 −하이볼륨 샘플링 및 GC/MS 분석방법을 대상으로
Evaluation of a Method for the Measurement of PAHs in the Ambient Atmosphere −Focusing on High Volume Sampling and GC/MS Analysis
3
조회
0
다운로드
7
인용
0
참고문헌
키워드
초록
In this study, a measurement method was evaluated for the determination of polycyclic aromatic hydrocarbons (PAHs) in the ambient atmosphere. PAHs were sampled by high-volume samplers, and were then analysed with a GC/MS system. Particulate PAHs were collected on 8''×10'' quartz fiber filter, while vapor phase PAHs were adsorbed on polyurethane foam (PUF). Target compounds included a total of 36 PAHs, which are known to be frequently detected in the urban atmosphere. It was not necessary to clean-up samples before samples were analyzed using GC/MS, and the overall performance of the method was tested by a variety of quality control and quality assurance schemes. It is generally known that the clean-up procedure can negatively affect the recovery of samples. Precision and accuracy was evaluated using SRM provided by US NIST, and the results were generally satisfactory and reliable. However, the GC/ MS method appeared not to be adequate for 6-rings PAHs, such as coronene, due to its lower sensitivity. In addition, collection efficiencies for low molecular compounds, such as 2-rings PAHs, were poor because of the lower retention volume of the PUF adsorbent. As a result, it was concluded that the method based on high-volume sampling and GC/ MS analysis can give very reliable data by simultaneous sampling of both particulate and vapor phases for 3-rings to 5-rings PAHs of environmental concern.
Abstract
In this study, a measurement method was evaluated for the determination of polycyclic aromatic hydrocarbons (PAHs) in the ambient atmosphere. PAHs were sampled by high-volume samplers, and were then analysed with a GC/MS system. Particulate PAHs were collected on 8''×10'' quartz fiber filter, while vapor phase PAHs were adsorbed on polyurethane foam (PUF). Target compounds included a total of 36 PAHs, which are known to be frequently detected in the urban atmosphere. It was not necessary to clean-up samples before samples were analyzed using GC/MS, and the overall performance of the method was tested by a variety of quality control and quality assurance schemes. It is generally known that the clean-up procedure can negatively affect the recovery of samples. Precision and accuracy was evaluated using SRM provided by US NIST, and the results were generally satisfactory and reliable. However, the GC/ MS method appeared not to be adequate for 6-rings PAHs, such as coronene, due to its lower sensitivity. In addition, collection efficiencies for low molecular compounds, such as 2-rings PAHs, were poor because of the lower retention volume of the PUF adsorbent. As a result, it was concluded that the method based on high-volume sampling and GC/ MS analysis can give very reliable data by simultaneous sampling of both particulate and vapor phases for 3-rings to 5-rings PAHs of environmental concern.
참고문헌 (22)
- Baek, S. O., "Effect o f ambient temperature on the distribution of atmospheric concentrations of polycyclic aromatic hydrocarbons in the vapor and particulate phases", Journal of Korea Air Pollution Research Association, 14(2), pp.117~131 (1998)
- Ravindra, K., "Atmospheric polycyclic hydrocarbons: Source attribution, emission factors and regulation", Atmospheric Environment, 42(13), pp.2895~2921 (2008)
- Baek, S. O., "Atmospheric polycyclic aromatic hydrocarbons - Environmental implications", Journal of Korean Society for Atmospheric Environment, 15(5), pp.525~544 (1999)
- Phillips, D. H., "Fifty years of benzo(a)pyrene", Nature, 303(9), pp.468~472 (1983)
- ATSDR, "Toxicological profile for polycyclic aromatic hydrocarbons", pp.2~6 (1995)
- Baek, S. O., "Occurrence and behaviour of polycyclic aromatic hydrocarbons in the ambient air(I) - Locational and seasonal concentrations", Journal of Korean Society of Environmental Engineers, 18(4), pp.465~480 (1996)
- Baek, S. O., "E valuation o f sampling methodology for the Measurement of Polycyclic aromatic hydrocarbons in the atmosphere", Journal of Korea Air Pollution Research Association, 14(1), pp.43~62 (1998)
- Baek, S. O., "Determination of polycyclic aromatic hydrocarbons associated with airborne particulate matter using HPLC and Fluorescence Detection", Journal of Korean Society of Environmental Engineers, 17(1), pp.85~99 (1995)
- Compendium Method TO-13A, Determination of polycyclic aromatic hydrocarbons in ambient air using gas chromatography, "mass spectrometry, 2nd. Ed", USEPA, 1999, EPA[DOI]
- 백성옥, "대기환경측정과 정도관리(Ⅰ) - 원리와 방법론", 한국대기환경학회지, 20(2), pp.237~249 (2004), 한국대기환경학회
- Chung, Y., "Seasonal variation of size distributions of polycyclic aromatic hydrocarbons in air particulates", Journal of Korea Air Pollution Research Association, 14(6), pp.577~588 (1998)
- Park, C. K., "A comparative study on the analytical methods of polycyclic aromatic hydrocarbons in the atmosphere", Journal of Korean Society for Atmospheric Environment, 16(6), pp.595~606 (2000)
- Pyo, H. S., "A study on the analysis of polycyclic aromatic hydrocarbons in air", Analytical Science and Technology, 13(4), pp.453~465 (2000)
- 이민도, "대기 중 다환방향족탄화수소(PAHs)의 측정?분석신뢰도 향상에 관한 고찰", 한국대기환경학회지, 23(5), pp.515~525 (2007), 한국대기환경학회
- IARC, "Agents reviewed by the IARC monographs. volumes 1-99", ~ (2008)
- Glaser, J. A., "Trace analysis for wastewaters", Environmental Science and Technology, 15(12), pp.1426~1435 (1981)
- USEPA, "Definition and procedure for the determination of the method detection limit, 40 CFR Part 136(analytical procedure), appendix B, 319", ~ (1990)
- ASC committee, "Guidelines for data acquisition and data quality evaluation in environmental chemistry", Analytical Chemistry, 52(14), pp.2242~2249 (1980)
- Compendium Method TO-17, Determination of volatile organic compounds in ambient air using active sampling onto sorbent tubes, 2nd. Ed, "USEPA", ~, pp.EPA (1999), 625[DOI]
- Maddalena, R. L., "Simple and rapid extraction of polycyclic aromatic hydrocarbons collected on polyurethane foam adsorbent", Atmospheric Environment, 32(14), pp.2497~1503 (1998)
- Seo, Y. H., "Determination of polycyclic aromatic hydrocarbons in chimney soot extract by high-resolution gas chromatography", Journal of Korea Air Pollution Research Association, 4(2), pp.11~19 (1988)
- Kim, S. C., "Trends in concentration of polycyclic aromatic hydrocarbons of PM-10 in Suwon area", Journal of Korea Air Pollution Research Association, 12(3), pp.341~350 (1996)
