응집침전에 의한 제철공장 냉각수질향상
Improvement of Cooling Water Quality by Coagulation and Sedimentation in Steel Mill
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
This study was initiated to improve the cooling water quality by chemical coagulation and sedimentation in steel mills. Due to the inefficient flocculation in the settling tanks of blast furnace cooling water systems, the solid particles in the cooling water overflow accumulate and clog the cooling system. To protect the cooling water system from such fouling, proper flocculants must be continuously used. Laboratory tests were performed for the indirect cooling water system of a plate mill. The batch test in the gas scrubbing cooling water system of a blast furnace showed that the proposed coagulant was more effective for the improvement of coagulation and sedimentation than the existing one. During the tests, cationic flocculants were more effective than use of only an anionic flocculant. The suggested combination of anionic and cationic flocculants can probably improve the turbidity removal efficiency of the cooling water. Proper control of the overflow rate by the designed residence time would help turbidity removal efficiency in the settling tank. In addition, the settling can be enhanced by adopting rapid and slow mixing alternatively. Scale problems in blast furnace cooling water system were reduced to some extent by efficient settling.
Abstract
This study was initiated to improve the cooling water quality by chemical coagulation and sedimentation in steel mills. Due to the inefficient flocculation in the settling tanks of blast furnace cooling water systems, the solid particles in the cooling water overflow accumulate and clog the cooling system. To protect the cooling water system from such fouling, proper flocculants must be continuously used. Laboratory tests were performed for the indirect cooling water system of a plate mill. The batch test in the gas scrubbing cooling water system of a blast furnace showed that the proposed coagulant was more effective for the improvement of coagulation and sedimentation than the existing one. During the tests, cationic flocculants were more effective than use of only an anionic flocculant. The suggested combination of anionic and cationic flocculants can probably improve the turbidity removal efficiency of the cooling water. Proper control of the overflow rate by the designed residence time would help turbidity removal efficiency in the settling tank. In addition, the settling can be enhanced by adopting rapid and slow mixing alternatively. Scale problems in blast furnace cooling water system were reduced to some extent by efficient settling.
참고문헌 (12)
- Grotefend, B. R., "Applying cooling water technology to improve steel mill operations", Iron and Steel Engineer, 57(6), pp.46~50 (1980)
- Lee, M, "Metallurgical performan ce o f the water-cooled l ance at t he BHP Sydney Steel Mill. A physical modelling study", Scandinavian Journal of Metallurgy, 30(4), pp.220~224 (2001)
- Zhao, H, "Application of TRASAR technique in Shanghai Baoshan Steel & Iron Group 1420 Cold Rolling Mill circulating cooling water system", Industrial Water Treatment, 20(3), pp.39~41 (2000)
- Yang, Z, "Temperature predicting model and cooling parameter setting model for water floor cooling in steel plate mill", Iron and Steel, 31(9), pp.34~38 (1996)
- Nemerow, N. L, "Industrial and Hazardous Waste Treatment", pp.478~502 (1991), Van Nostrand Reinhold
- Betz Laboratories, "Betz Handbook of Industrial Water Conditioning, 9th Ed" (1991)
- Osantowski, R, "Treatment of Steel Plant Blast Furnace Effluent Using Physical", Chemical Techniques, 1980, 725~
- Blast Furnaces and Steel Mills, Industrial Waste Profile, III(1), "U.S. Department of the Interior", ~ (1967)
- 조관형, "동관에서 pH, 알칼리도, 염소이온이 부식에 미치는 영향", 한국환경보건학회지, 33(1), pp.43~48 (2007), 한국환경보건학회
- Herro, H. M, "The NALCO guide to cooling water systems failure analysis", pp.160~210 (1993), McGraw-Hill, Inc.
- 조관형, "부식 및 스케일 억제제에 의한 냉각수 수질향상", 한국환경과학회지, 18(2), pp.187~195 (2009), 한국환경과학회
- Standard Methods for the Examination of Water and Wastewater, "APHA", APHA, ~ (1989)
