본문 바로가기
KERD
논문

멀티 플라즈마 반응기를 이용한 E. coli 소독

E. coli Disinfection Using a Multi Plasma Reactor

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

Objectives: For the practical application of the dielectric barrier discharge plasma reactor, a plasma reactor able to manage large volumes of water is needed. This study investigated the possibility of the practical application of a multi-plasma reactor which is a scaled-up version of a single plasma reactor. Methods: The multi-plasma reactor consists of several high-voltage transformers and plasma modules (discharge, ground electrodes and quartz dielectric tubes). The effects of water characteristics such as voltage (30-120 V), air flow rate (1-5 l/min), number of high-voltage transformers and plasma modules, and water quality on Escherichia coli (E. coli) disinfection and decrease of COD and UV254 absorbance were investigated. Results: The experimental results showed that at a voltage of over 80 V, most of the E. coli were disinfected within 90 seconds. E. coli inactivation was not affected by the air flow rate. E. coli disinfection in the multiplasma process showed the traditional log-linear form of the disinfection curve. E. coli inactivation performance by transformer 3-Reactor 5 and transformer 3-Reactor 3 were similar. The disinfection performance of the UV process was affected by artificial sewage water. However, the plasma process was less affected by the artificial sewage within the standards for effluent water quality. Conclusions: Disinfection performance with several low voltages and plasma modules of three to five in number applied to the plasma process was higher than that concentrating a small amount of high voltage through a single plasma reactor. Removal of COD, UV254 absorbance, and E. coli disinfection with the plasma process were better than with the UV process.

Abstract

Objectives: For the practical application of the dielectric barrier discharge plasma reactor, a plasma reactor able to manage large volumes of water is needed. This study investigated the possibility of the practical application of a multi-plasma reactor which is a scaled-up version of a single plasma reactor. Methods: The multi-plasma reactor consists of several high-voltage transformers and plasma modules (discharge, ground electrodes and quartz dielectric tubes). The effects of water characteristics such as voltage (30-120 V), air flow rate (1-5 l/min), number of high-voltage transformers and plasma modules, and water quality on Escherichia coli (E. coli) disinfection and decrease of COD and UV254 absorbance were investigated. Results: The experimental results showed that at a voltage of over 80 V, most of the E. coli were disinfected within 90 seconds. E. coli inactivation was not affected by the air flow rate. E. coli disinfection in the multiplasma process showed the traditional log-linear form of the disinfection curve. E. coli inactivation performance by transformer 3-Reactor 5 and transformer 3-Reactor 3 were similar. The disinfection performance of the UV process was affected by artificial sewage water. However, the plasma process was less affected by the artificial sewage within the standards for effluent water quality. Conclusions: Disinfection performance with several low voltages and plasma modules of three to five in number applied to the plasma process was higher than that concentrating a small amount of high voltage through a single plasma reactor. Removal of COD, UV254 absorbance, and E. coli disinfection with the plasma process were better than with the UV process.

참고문헌 (24)

  1. 김유리, "전자선을 이용한 하수처리장 방류수내 대장균군 살균", 한국물환경학회지, 20(4), pp.376~381 (2004), 한국물환경학회
  2. Ministry of Environment, "General guidelines for business transactions handled the installation of the sewage treatment plant disinfection facilities", ~ (2002)
  3. 김동석, "전기+UV 공정에 의한 E. coli 불활성화", 한국물환경학회지, 25(5), pp.667~673 (2009), 한국물환경학회
  4. Jung KW, "Investigation on the application of UV disinfection for reuse of secondary effluent", Kor Soc on Wat EnvironKor Soc of Wat and Wastewat. 2004 Joint Spring conference Proceeding, pp.189~192 (2004)
  5. 김동석, "E. coli 불활성화와 산화제 생성에 미치는 소독 공정 결합의 영향", 한국환경과학회지, 20(7), pp.891~898 (2011), 한국환경과학회
  6. Karl GU, "Ultraviolet disinfection of wastewater: effect of dose on subsequent photoreactivation", Wat Res, 28(4), pp.805~817 (1994)
  7. Park YS, "E. coli removal using multiple disinfection process", Proceeding Kor Environ Sci Soc Conf, pp.258~291 (2009)
  8. Pei X, "Wastewater disinfection by ozone: main parameters for process design", Wat Res, 36, pp.1043~1055 (2002)
  9. Hataitip Nimitkeatkai, "Washing Efficiency of Acidic Electrolyzed Water on Microbial Reduction and Quality of ‘Fuji’ Apples", 원예과학기술지, 27(2), pp.250~255 (2009), 한국원예학회
  10. 김동석, "3차원 전극을 사용한 Rhodamine B의 전기분해에 미치는 운전인자의 영향", 한국환경보건학회지, 35(4), pp.295~303 (2009), 한국환경보건학회
  11. 김동석, "유전체 장벽 방전 플라즈마 방전수의 특성과 미생물 소독에 관한 연구", 한국환경보건학회지, 38(02), pp.159~165 (2012), 한국환경보건학회[DOI]
  12. Moon JH, "Phenol conversion by pulsed corona discharges in aqueous solution", Kor Soc Environ Eng, Spring Conference Proceeding, pp.1~3 (2008)
  13. Shi J, "Organic contaminants removal by the technique of pulsed high-voltage discharge in water", J Hazard Mat, 171, pp.924~931 (2009)
  14. 김동석, "수처리용 유전체장벽 플라즈마 반응기에 대한 기초 연구", 한국환경과학회지, 20(5), pp.623~630 (2011), 한국환경과학회
  15. 김동석, "수중 플라즈마 공정을 이용한 Rhodamine B 염료의 제거", 한국환경보건학회지, 37(3), pp.218~225 (2011), 한국환경보건학회
  16. Park YS, "The design of a multi-plasma process", Proceed Kor Soc Environ Health, 98 (2011)
  17. 이장훈, "인공하수 조성 성분에 따른 SBR 처리 공정의 효율에 관한 연구", 한국환경보건학회지, 31(2), pp.99~106 (2005), 한국환경보건학회
  18. APH-AWWA-WPCE, "Standard Methods for the Examination of Water and Wastewater" (1992), APHA
  19. 김동석, "플라즈마 처리에 의한 양액 성분 변화", 한국환경과학회지, 21(3), pp.363~368 (2012), 한국환경과학회
  20. 백영애, "오존 및 입상활성탄 도입시 후염소 주입량 저감효과 분석", 상하수도학회지, 21(4), pp.445~452 (2007), 대한상하수도학회
  21. Tezcanli-Guyer G, "Degradation and toxicity reduction of textile dyestuff by ultrasound", Ultraso Sonochem, 10, pp.235~240 (2003)
  22. 백상은, "플라즈마 공정에 대한 소독 모델 적용", 한국환경과학회지, 21(6), pp.695~704 (2012), 한국환경과학회
  23. 김동석, "냉각탑수 수질이 Ru", Ti 전극을 이용한 Legionella pneumophila 소독에 미치는 영향, 2008, pp.17(6), 581~589[DOI]
  24. 박영식, "전기분해 공정을 이용한 E. coli 소독에 미치는 인공하수 수질의 영향", 한국환경과학회지, 20(9), pp.1115~1124 (2011), 한국환경과학회

관련 논문AI추천

이 간행물의 다른 논문 (9건)