일부 공단지역 내 이산화질소에 의한 개인노출 농도에 관한 연구
Personal Exposure Level of Nitrogen Dioxide in an Industrial Area
1
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
This study was conducted in industrial area. The level of nitrogen dioxide was measured indoor, outdoor, work and personal in an study area within 5 km from source of pollution and control area 15 km farther from August, 2006 to September. The followings are the summary of this research. The concentration of the indoor and the outdoor NO2 levels in the industrial area are 18.41±6.35 ppb, 18.51±3.26 ppb each, and the indoor/outdoor concentration rate is 0.99. The concentration of NO2 in the workplace is 18.59±10.16 ppb, and the individual exposure rate is 18.80±5.71 ppb. The concentration of the indoor and the outdoor NO2 levels control area are 12.57±3.82 ppb, 9.68±2.16 ppb each, and the indoor/outdoor concentration rate is 1.33. The personal exposure rate is 14.49±10.06 ppb. The residents of the each area and those of the comparative area spend 80.9% and 76.9% each their time in the indoor. It shows they spend most of their time in indoor. The predictions of the individual exposure rates in the industrial area and the comparative area are 15.10±6.14 ppb and 10.52±3.82 ppb each, The concentration levels measured by passive sampler are 18.80±5.71 ppb and 14.49±10.34 ppb each. The result of the research is the analysis of the personal exposure rate in indoor, outdoor and workplace of industrial area. This research may bo used as a basic data to manage and to establish the plan for NO2 gas of the industrial area.
Abstract
This study was conducted in industrial area. The level of nitrogen dioxide was measured indoor, outdoor, work and personal in an study area within 5 km from source of pollution and control area 15 km farther from August, 2006 to September. The followings are the summary of this research. The concentration of the indoor and the outdoor NO2 levels in the industrial area are 18.41±6.35 ppb, 18.51±3.26 ppb each, and the indoor/outdoor concentration rate is 0.99. The concentration of NO2 in the workplace is 18.59±10.16 ppb, and the individual exposure rate is 18.80±5.71 ppb. The concentration of the indoor and the outdoor NO2 levels control area are 12.57±3.82 ppb, 9.68±2.16 ppb each, and the indoor/outdoor concentration rate is 1.33. The personal exposure rate is 14.49±10.06 ppb. The residents of the each area and those of the comparative area spend 80.9% and 76.9% each their time in the indoor. It shows they spend most of their time in indoor. The predictions of the individual exposure rates in the industrial area and the comparative area are 15.10±6.14 ppb and 10.52±3.82 ppb each, The concentration levels measured by passive sampler are 18.80±5.71 ppb and 14.49±10.34 ppb each. The result of the research is the analysis of the personal exposure rate in indoor, outdoor and workplace of industrial area. This research may bo used as a basic data to manage and to establish the plan for NO2 gas of the industrial area.
참고문헌 (20)
- Risk assessment and management of air pollutant, "Ministry of Environment", ~ (1998)
- Kim, Y. S., "Personal, Indoor and Outdoor NO2 Measurements in an Urban Area", Korean Journal of Environmental Health, 3(2), pp.33~38 (1987)
- Yang, W. H., "A study on concentration of indoor nitrogen dioxide in relation to house characteristics", Korean Journal of Sanitation, 14(4), pp.85~92 (1999)
- WHO, "Air quality guidelines for Europe", WHO Rub. European Series, 23 (1987)
- Lee, J. T., "Air pollution and daily mortality in Seoul and Ulsan. Korea", Environmental Health Perapectines, 107(2), pp.149~154 (1999)
- Spengler, J. D., "Nitrogen dioxide and respiratory illness in children. Part IV: Effect of housing and meteorologic factors on indoor nitrogen dioxide concentrations", Research Report-Health Effects Institute, 58, pp.1~29 (1996)
- Nielson, O. R., "Front-door concentrations and personal exposure of danish children to nitrogen dioxide", Environmental Health Perspectives, 105(9), pp.964~970 (1997)
- UNEP, "WHO", Passive and Active sampling Methodologies for Measurement of Air Quality, AIR Methodologies Review Handbook Series, pp.1995, 14[DOI]
- Yanagisawa, Y, "A badge-type personal sampler for measurement of personal eaposure to NO2 and NO in ambient air", Environment Intermational, 8, pp.235~242 (1982)
- 양원호, "실내 및 실외 공기중 이산화 질소의 개인노출량 측정을 위한 수도식 시료채취기의 성능평가", 대기환경학회지, 16(6), pp.625~631 (2000)
- Yang, W.-H., "Exposure assessment and estimation of personal exposure for nitrogen dioxide using time weighted average model", Journal of Korea Public Health Association, 17(3), pp.251~258 (2001)
- Christopher, Y. H., "A study of personal exposure to nitrogen dioxide using passive samplers", Building and Environment, 35, pp.533~545 (2000)
- Cho, J., "Effect of residential air quality in accordance with dispersion of nitrogen dioxide from line sources on the road", Journal of Korea Public Health Association, 28(4), pp.373~379 (2002)
- Kim, W.-J., "A study on property of nitrogen dioxide concentration using passive sampler in industrial areas", 석사, Department of Environmental Engineering, pp.2000
- Jung, S.-W., "A study of risk assessment and indoor air quality assessment of NO2 and VOCs in apartments", 석사, Department of Environment Health, pp.2005
- Levy, J. I., "Impact of residential nitrogen dioxide exposure on personal exposure: An international study", Journal of the Air & Waste Management Association, 48(6), pp.553~560 (1998)
- Bang, Y. N., "Estimation of exposure to nitrogen dioxide in professional drivers using time activity pattern", Korea Journal of Environmental Health Society, 27(1), pp.22~26 (2001)
- Kim, Y. S., "Indoor and outdoor NO2 measurements in homes", Journal of Korean Society for Atmospheric Environment, 1, pp.189~190 (1996)
- Dimitroulopoulou, C., "Modeling of indoor exposure on personal exposure to nitrogen dioxide", Atmospheric Environment, 35, pp.269~279 (2001)
- Exposure Factor Handbook, "Ministry of Environment", ~ (2001)
