초록
This study evaluated the bacterial concentrations and affecting factors at the laboratories of a university in Seoul, Korea. Thirty-three samples of total airborne bacteria (TAB) and eighteen samples of gram negative bacteria (GNB) were collected from both microbiology laboratories (7) and chemistry laboratories (6). GM (GSD) of TAB and GNB concentrations were 194 (2.52) cfu/㎥, 24 (4.1) cfu/㎥, respectively. TAB concentrations in the chemical laboratories (GM (GSD): 193 (2.0) cfu/㎥) were not significantly different from those in microbial laboratories (GM (GSD): 202 (2.7) cfu/㎥, (p>0.05)). GM (GSD) of TAB concentrationsat the top of sink, the center of laboratory, and the front of ventilation ventilation device within laboratories, 182 (3.2) cfu/㎥, 217 (2.2) cfu/㎥, 176 (2.4) cfu/ ㎥, respectively, were not significantly different (p=0.48). Related factors were measured such as temperature, relative humidity, floor of laboratory, number of persons and laboratory area. TAB concentrations were significantly related to temperature (r=0.36, p<0.05), and the floor of laboratory and temperature were also significantly related (r=0.49, p<0.001). However, other factors such as relative humidity, number of persons and laboratory area did not show any significant relationship with TAB concentrations (p>0.05). TAB concentrations were affected significantly by cleaning frequency (p<0.001) and floor of laboratory (p<0.05). There was also a significant difference (p<0.01) between TAB indoor concentrations and TAB outdoor concentrations. However, other factors such as general ventilation did not affect TAB concentrations (p>0.05) in this study.
Abstract
This study evaluated the bacterial concentrations and affecting factors at the laboratories of a university in Seoul, Korea. Thirty-three samples of total airborne bacteria (TAB) and eighteen samples of gram negative bacteria (GNB) were collected from both microbiology laboratories (7) and chemistry laboratories (6). GM (GSD) of TAB and GNB concentrations were 194 (2.52) cfu/㎥, 24 (4.1) cfu/㎥, respectively. TAB concentrations in the chemical laboratories (GM (GSD): 193 (2.0) cfu/㎥) were not significantly different from those in microbial laboratories (GM (GSD): 202 (2.7) cfu/㎥, (p>0.05)). GM (GSD) of TAB concentrationsat the top of sink, the center of laboratory, and the front of ventilation ventilation device within laboratories, 182 (3.2) cfu/㎥, 217 (2.2) cfu/㎥, 176 (2.4) cfu/ ㎥, respectively, were not significantly different (p=0.48). Related factors were measured such as temperature, relative humidity, floor of laboratory, number of persons and laboratory area. TAB concentrations were significantly related to temperature (r=0.36, p<0.05), and the floor of laboratory and temperature were also significantly related (r=0.49, p<0.001). However, other factors such as relative humidity, number of persons and laboratory area did not show any significant relationship with TAB concentrations (p>0.05). TAB concentrations were affected significantly by cleaning frequency (p<0.001) and floor of laboratory (p<0.05). There was also a significant difference (p<0.01) between TAB indoor concentrations and TAB outdoor concentrations. However, other factors such as general ventilation did not affect TAB concentrations (p>0.05) in this study.
참고문헌 (25)
- Xiang, L, "Prompt tracking of indoor airborne contaminant source location with probability-based inverse multi-zone modeling", Building and Environment, 44, pp.1135~1143 (2009)
- American Conference of Governmental Industrial Hygienists, "Guidelines for the assessment of bioaerosols in the indoor environment" (1989)
- Indoor air quality. : biological contaminants, "World Health Organization", WHO regional publications, ~, pp.European series no, 31 (1999)
- Douwes, J, "Bioaerosol health effects and exposure assessment progress and prospects", Annals of Occupational Hygiene, 47, pp.187~200 (2003)
- Owen, M. K, "Airborne particle sizes and sources found in indoor air", Atmospheric Environment, 26(A), pp.2149~2162 (1992)
- 김기연, "사료제조공장 내 공기 중 세균과 진균 분포에 관한 연구", 한국산업위생학회지, 17(4), pp.335~342 (2007), 한국산업위생학회
- Fisher, G, "Exposure to airborne fungi, MVOC and mycotoxins in biowaste-handling facilities", International Journal of Hygiene and Environmental Health, 203, pp.97~104 (2000)
- Burge H, "Bioareosols : prevalence and health effects in the indoor environment", Journal of Allergy Clinical Immunology, 86, pp.687~701 (1990)
- Lee, S. C, "Intercomparison of air pollutant concentrations in different indoor environment in Hong Kong", Atmospheric Environment, 36, pp.1929~1940 (2002)
- Awad, A. H. A, "Environmental study in subway metro stations in Cairo, Egypt", Journal of Occupational Health, 44, pp.112~118 (2002)
- Jo, W. K, "Indoor and outdoor bioaerosol levels at recreation facilities, elementary schools, and homes", Chemospehre, 61, pp.1570~1579 (2005)
- Zuraimi, M. S, "Indoor air quality and its determinants in tropical child care centers", Atmospheric Environment, 42, pp.2225~2239 (2008)
- NIOSH, "Sampling and characterization of bioaerosols", NIOSH Manual Analytical Methods, 4, pp.82~112 (1998)
- Bullock, W. H, "A Strategy for assessing and managing occupational exposures, 3rd ed"
- "American Industrial Hygiene Association, Fairfax, VA", 349~355 (2006)
- Lee, S. C, "Investigation of indoor air quality at residential homes in Hong Kong", Atmospheric Environment, 36, pp.225~237 (2002)
- 김기연, "일반 사무실 실내공기 내 부유미생물의 분포 양상", 한국산업위생학회지, 18(1), pp.11~19 (2008), 한국산업위생학회
- Charriere. N, "Effects of bioaerosol exposure on work-related symptoms among Swiss sawmill workers", International Arch Occupational Environment Health, 1, pp.12~17 (2007)
- Guo, H, "Indoor air quality investigation at air-conditioned and non-air conditioned markets in Hong Kong", International Journal of Science Total Environment, 323, pp.87~98 (2004)
- Ren, P, "The relation between fungal propagules in indoor air and home characteristics", Allergy, 56, pp.419~424 (2001)
- Tsai, M. Y, "Exposure to culturable airborne bioaerosols during noodle manufacturing in central Taiwan", International Journal of Science Total Environment, 10, pp.1016~ (2008)
- Mui, K. W, "Risks of unsatisfactory airborne bacteria level in air-conditioned offices of subtropical climates", Building and Environment, 43, pp.475~479 (2008)
- Hirst, J. M, "Long distance spore transport : methods of measurement, vertical spore profiles and the detection of immi grant spores", Journal of General Microbiology, 48, pp.329~355 (1967)
- Scheff, P. A, "Indoor air quality in a middle school, Part 2: development of emission factors for particulate matter and bioaerosols", Applied Occupational and Environmental Hygiene, 15, pp.835~842 (2000)
- Lee, J. H, "Characteristics of indoor and outdoor bioaerosals at Korean high-rise apartment buildings", Environmental Research, 101, pp.11~17 (2006)