Objectives: This study was undertaken in order to evaluate by work space zoning and structure the concentrations of biological contaminants in the indoor air of domestic office buildings. Methods: Air samples were collected in the office spaces of 15 office buildings in Seoul from June 28 to July 28, 2011. Prior to the sampling, each office was classified into 'open-plan office', 'cellular office' and 'mixed office' according to the work space zoning. To evaluate the biological contamination of indoor air, total suspended bacteria (TSB), Gram positive bacteria (GPB), Staphylococcus aureus (S.A), Methicillin-resistant Staphylococcus aureus (MRSA), Gram negative bacteria (GNB) and fungi were investigated. During the sampling, temperature, relative humidity and carbon dioxide (CO2) were measured. Results: The TSB concentrations (GM±GSD) were 452 (±1.3) cfu/m3 in open-plan offices, 366 (±1.3) cfu/m3in cellular offices and 287 (±1.5) cfu/m3 in mixed offices, and there were significant differences between the three groups (p<0.05). The highest concentrations (GM ± GSD) of fungi were found in the indoor air of cellular offices 128(±1.0) cfu/m3, which was at least three times higher than the concentrations in mixed offices 43 (±1.0)cfu/m3 (p<0.05). Conclusions: Microbiological contamination in the indoor air of office buildings by work space structure was the highest with the open-plan office layout which includes no high walls or doors separating the occupants

Abstract

Objectives: This study was undertaken in order to evaluate by work space zoning and structure the concentrations of biological contaminants in the indoor air of domestic office buildings. Methods: Air samples were collected in the office spaces of 15 office buildings in Seoul from June 28 to July 28, 2011. Prior to the sampling, each office was classified into 'open-plan office', 'cellular office' and 'mixed office' according to the work space zoning. To evaluate the biological contamination of indoor air, total suspended bacteria (TSB), Gram positive bacteria (GPB), Staphylococcus aureus (S.A), Methicillin-resistant Staphylococcus aureus (MRSA), Gram negative bacteria (GNB) and fungi were investigated. During the sampling, temperature, relative humidity and carbon dioxide (CO2) were measured. Results: The TSB concentrations (GM±GSD) were 452 (±1.3) cfu/m3 in open-plan offices, 366 (±1.3) cfu/m3in cellular offices and 287 (±1.5) cfu/m3 in mixed offices, and there were significant differences between the three groups (p<0.05). The highest concentrations (GM ± GSD) of fungi were found in the indoor air of cellular offices 128(±1.0) cfu/m3, which was at least three times higher than the concentrations in mixed offices 43 (±1.0)cfu/m3 (p<0.05). Conclusions: Microbiological contamination in the indoor air of office buildings by work space structure was the highest with the open-plan office layout which includes no high walls or doors separating the occupants

참고문헌 (32)

  1. National Academy of Sciences (NAS), "Human exposure assessment for airborne pollutants", ~ (1993)
  2. Robinson J, "National human activity pattern survey data base. US EPA, Reaseach triangle park, NC", ~ (1995)
  3. World Health Organization (WHO)., "Air quality guidelines for Europe, 2nd ed. Copenhagen, World Health Organization Regional Office for Europe", WHO Regional Publications, European Series, No. 91, ~ (2000)
  4. Woods JE, "Problem buinding; building associated illness and sick building syndrome", Med State Art Rev, 4, pp.753~770 (1989)
  5. Occupational Safety and Health Administration (OSHA)., "Indoor Air Quality", 59, pp.15968~16039 (2001)
  6. 노영만, "사무실 내 실내공기질 특성 및 근무자의 자각증상에 관한 연구", 한국산업위생학회지, 14(3), pp.270~282 (2004), 한국산업위생학회
  7. 이철민, "국내 부유미생물에 관한 연구 동향", 한국실내환경학회지, 4(1), pp.59~71 (2007), 한국실내환경학회
  8. Miller SYS, "Macher guest editorial", Aerosol Sci. Technol, 30, pp.93~99 (1999)
  9. Bernstein RS, "Exposures to respirable, airborne penicillium from contaminated ventilation system, clinical, environmental and epidemiological aspects", Am Ind Hyg Assoc J, 44, pp.161~ (1983)
  10. Oommen VG, "Should health service managers embrace open plan work environments? a review", Asia Pacific Journal of Health Management, 3(2), pp.37~43 (2008)
  11. 김윤신, "다중이용시설에서의 실내공기 중 미생물 분포에 관한 연구", 한국환경보건학회지, 28(1), pp.85~92 (2002), 한국환경보건학회
  12. 이철민, "다중이용시설내 공기중 바이오에어로졸 농도분포 특성에 관한 연구", 한국환경과학회지, 13(3), pp.215~222 (2004), 한국환경과학회
  13. 김기연, "일반 사무실 실내공기 내 부유미생물의 분포 양상", 한국산업위생학회지, 18(1), pp.11~19 (2008), 한국산업위생학회
  14. Tsai FC, "Concentrations of airborne culturable bacteria in 100 large US office buildings from the BASE study", Indoor Air, 15(9), pp.71~81 (2005)
  15. Sessa R, "Microbiological indoor air quality in healthy buildings", New Microbiol, 25(1), pp.51~56 (2002)
  16. Keum JS, "Air Conditioning", pp.22~ (2000), Taehoon Publisher
  17. Ministry of knowledge economy, "Revising the energy utilization act. Paragraph 2 of Article 7 No. 9", ~ (2010)
  18. Ikeda K, "Indoor air pollution causes and countermeasures", pp.15~86 (2004), Sudopremium engineering Publisher
  19. American society of refrigerating and air conditioning engineers (ASHRAE), "Thermal environment conditions for human occupancy" (1992), Atlanta, ASHRAE, Inc
  20. 정지연, "업무용 빌딩 내 사무실의 실내공기질 평가", 한국산업위생학회지, 17(1), pp.31~42 (2007), 한국산업위생학회
  21. Jeong JY, "Office air quality assessment and management standards development (I)" (2004), The Korea Occupational Safety and Health Agency (KOSHA)
  22. 이경희, "오피스 빌딩 실내환경 특성이 인체에 미치는 영향에 관한 연구", 대한건축학회논문집 계획계, 22(12), pp.37~44 (2006), 대한건축학회
  23. Erdmann CA, "Inoor carbon dioxide concentrations and sick building syndrome symptoms in the base study", Indoor Air J USA (2002)
  24. Nevalainen A, "Fungi and bacteria in normal andmouldy dwellings", pp.155~162 (1994), Health Implications of Fungi in Indoor Environments
  25. "ASHRAE 62-2001, Handbook-HVAC application", ASHRAE Inc, ~ (2003)
  26. Morey PJ, "Airborne viable microorgan ism in office environments sampling protocol and analytical procedures", Appl Ind Hyg, 1(1), pp.19~ (1986)
  27. Bonetta S, "Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system", Environ Monit Assess, 161, pp.473~483 (2010)
  28. 황성호, "Exposure Level of Airborne Bacteria in the University Laboratories in Seoul, Korea", 한국환경보건학회지, 35(5), pp.355~361 (2009), 한국환경보건학회
  29. Hwang SH, "Airborne bacteria concentrations and related factors at university laboratories, hospital diagnostic laboratories and a biowaste site", J Clin Pathol, 64(3), pp.264~264 (2011)
  30. Myatt TA, "Detection of airborne rhinovirus and its relation to outdoor air supply in office environments", Am J Respir Crit Care Med, 169(11), pp.1187~1190 (2004)
  31. 윤혜경, "생산성 향상을 위한 북미 최첨단 사무공간 계획 방향 분석", 한국실내디자인학회 논문집, 19(1), pp.200~207 (2010), 한국실내디자인학회
  32. International Facility Management Association, "Research Report #18: Benchmarks III", ~ (1997)

관련 논문AI추천

이 간행물의 다른 논문 (10건)