The indoor environmental condition was assessed in houses with allergy (asthma and atopy) patients by use of a fungal detector. The fungal index was calculated from the growth rate of the sensor fungi in a fungal detector encapsulating the spores, Alternaria alternata S-78, Eurotium herbariorum J-183 and Aspergillus penicillioides K-712. Fungal indices were higher in asthma patient’s houses than in control houses and Eurotium herbariorum showed the highest growth response among the sensor fungi. Dust mites allergen, Der f1, was also significantly high in allergy patient's houses where fungal indices above 10 were detected. A correlation was observed between the fungal indices and dust mite allergen proliferations in examined houses. Therefore, the fungal index can be a useful tool as an indirect indication for detecting chronic dampness that brings both contaminations by fungi and dust mite.
Abstract
The indoor environmental condition was assessed in houses with allergy (asthma and atopy) patients by use of a fungal detector. The fungal index was calculated from the growth rate of the sensor fungi in a fungal detector encapsulating the spores, Alternaria alternata S-78, Eurotium herbariorum J-183 and Aspergillus penicillioides K-712. Fungal indices were higher in asthma patient’s houses than in control houses and Eurotium herbariorum showed the highest growth response among the sensor fungi. Dust mites allergen, Der f1, was also significantly high in allergy patient's houses where fungal indices above 10 were detected. A correlation was observed between the fungal indices and dust mite allergen proliferations in examined houses. Therefore, the fungal index can be a useful tool as an indirect indication for detecting chronic dampness that brings both contaminations by fungi and dust mite.
참고문헌 (17)
- Abe, K, "Assessment of indoor climate in an apartment by use of a fungal index", Applied and Environmental Microbiology, 62(3), pp.959~963 (1996)
- Abe, K, "Fungal Contamination Causing adverse effects on human health-detection of its liability in dwellings", Proceedings of Japan-Canada Housing R&D Experts Working Group Meeting, 4, pp.269~278 (2003)
- Abe, K, "Fungal index in dwelling environments", pp.649~654 (2003), Proceedings : Healthy Buildings 2003
- Akiyama, K, "Fungal allergy in the indoor environment", Indoor Environment, 10(1), pp.11~16 (2007)
- Abe, K, "Assessment of the environmental conditions in a museum storehouse by use of fungal", International Biodeterioration & Biodegradation, 64, pp.32~40 (2010)
- Roaa, M. A, "Association of asthma symptoms and severity with indoor bioaerosol", Allergy, 55, pp.705~711 (2000)
- Development of human monitoring and management systems for asthma, allergy and sick building syndrome caused by air pollutants using immunological and family unit methodology, "Kim, Y. H", Report of Ministry of Environment, 43~48 (2008)
- 문경환, "알레르기 환자 가정에서 생물학적 유해인자에 대한 노출평가 -세균, 진균, 집먼지 진드기 알레르겐, 내독소를 대상으로", 한국환경보건학회지, 31(2), pp.120~126 (2005), 한국환경보건학회
- Abe, K, "Comparison of a measured fungal index determined using fungal growth and computed fungal index based on temperature and relative humidity", Journal of Society of Indoor Environment, 9(1), pp.17~24 (2006)
- Lee,I.-S, "Dwelling environment of bronchial asthma patients and the amount of house dust mite allergens", Journal of Korean Public Health Association, 28(2), pp.188~197 (2002)
- 박주형, "실내환경에서 생물학적 인자에 대한 노출평가", 한국환경보건학회지, 35(4), pp.239~248 (2009), 한국환경보건학회
- The Korean Academy of Asthma, "Allergy and Clinical Immunology : Asthma and Allergic Diseases", pp.99~106 (2002), KoonJa Publishing Co
- Platts-Mills, T. A, "Seasonal variation in dust mite and grass-pollen allergens in dust from the houses of patients with asthma", Jounal of Allergy and Clinical Immunology, 79, pp.781~791 (1987)
- Goplen, N, "Combined sensitization of mice to extracts of dust mite, ragweed, and Aspergillus species breaks through tolerance and establishes chronic features of asthma", Journal of Allergy Clinical Immunology, 123(4), pp.925~932 (2009)
- 김기연, "일반 사무실 실내공기 내 부유미생물의 분포 양상", 한국산업위생학회지, 18(1), pp.11~19 (2008), 한국산업위생학회
- Kim, Y. K, "Distribution of fungus spores in the air of outdoors, indoors(apartment) and underground markets during summer (June, July and August, 1995)", Journal of the Korean Academy of Pediatric Allergy and Respiratory Disease, 6(2), pp.123~135 (1995)
- Vesper, S, "Development of an environmental relative moldiness index for US homes", Journal of Occupational and Environmental Medicine, 49, pp.829~833 (2007)