Objectives: This study was performed in order to determine airborne fungi levels in homes and find related factors that may affect airborne fungi concentration. Methods: Fifty homes were study subjects for measuring airborne fungi. For sampling airborne fungi, the impaction method on agar plates was used and samples were counted as colony forming units per cubic meter of air (CFU/m3). In addition, information regarding housing characteristics and atopic disease in each home were collected via questionnaire. Results: The geometric means (GM) of airborne fungi concentrations in fifty living rooms and bedrooms were 68.03 and 62.93 CFU/m3, respectively. The GM of airborne fungi concentration in atopy homes was 78.42 CFU/m3. This was higher than non-atopy homes’ 54.34 CFU/m3 (p-value=0.051). In the results of the multiple regression analysis, outdoor airborne fungal concentration proved a strong effective factor on indoor airborne fungal concentration. Also, construction year, floor area of house, indoor smoking and frequency of ventilation were factors that showed a significant association with indoor airborne fungi concentration. Conclusions: The results of this study show that some housing and living characteristics may affect the development and increase of airborne fungi. In addition, exposure to airborne fungi may be a risk factor for the prevalence of childhood atopic diseases.
Abstract
Objectives: This study was performed in order to determine airborne fungi levels in homes and find related factors that may affect airborne fungi concentration. Methods: Fifty homes were study subjects for measuring airborne fungi. For sampling airborne fungi, the impaction method on agar plates was used and samples were counted as colony forming units per cubic meter of air (CFU/m3). In addition, information regarding housing characteristics and atopic disease in each home were collected via questionnaire. Results: The geometric means (GM) of airborne fungi concentrations in fifty living rooms and bedrooms were 68.03 and 62.93 CFU/m3, respectively. The GM of airborne fungi concentration in atopy homes was 78.42 CFU/m3. This was higher than non-atopy homes’ 54.34 CFU/m3 (p-value=0.051). In the results of the multiple regression analysis, outdoor airborne fungal concentration proved a strong effective factor on indoor airborne fungal concentration. Also, construction year, floor area of house, indoor smoking and frequency of ventilation were factors that showed a significant association with indoor airborne fungi concentration. Conclusions: The results of this study show that some housing and living characteristics may affect the development and increase of airborne fungi. In addition, exposure to airborne fungi may be a risk factor for the prevalence of childhood atopic diseases.
참고문헌 (29)
- 김기연, "서울시 일부 지역의 대기 중 부유 진균의 분포 특성", 한국환경보건학회지, 38(5), pp.407~414 (2012), 한국환경보건학회[DOI]
- 조준호, "A case report on fungal contamination and remediation in a leakage-water damaged apartment", 한국환경보건학회지, 32(5), pp.418~423 (2006), 한국환경보건학회
- Norbäck D, "Mould and dampness in dwelling places, and onset of asthma: the population-based cohort ECRHS", Occup Environ Med, 70(5), pp.325~331 (2013)
- Quansah R, "Residential dampness and molds and the risk of developing asthma: a systematic review and meta-analysis", PloS One, 7(11), pp.e47526~ (2012)
- Hwang BF, "Molds, parental atopy and pediatric incident asthma", Indoor Air, 21(6), pp.472~478 (2011)
- Han YY, "Indoor environmental risk factors and seasonal variation of childhood asthma", Pediatr Allergy Immunol, 20(8), pp.748~756 (2009)
- Fisk WJ, "Meta-analyses of the associations of respiratory health effects with dampness and mold in homes", Indoor Air, 17(4), pp.284~296 (2007)
- 조준호, "서울시 일부 지하철 역사 내 공기 중 진균 농도에 관한 연구", 한국환경보건학회지, 35(6), pp.478~485 (2009), 한국환경보건학회
- Riggs MA, "Resident cleanup activities, characteristics of flood-damaged homes and airborne microbial concentrations in New Orleans, Louisiana, October 2005", Environmental Research, 106(3), pp.401~409 (2008)
- Roussel S, "Characteristics of dwellings contaminated by moulds", J Environ Monit, 10(6), pp.724~729 (2008)
- 문현준, "설문조사를 통한 주거건물의 곰팡이 발생 현황 연구", 한국실내환경학회지, 7(1), pp.25~32 (2010), 한국실내환경학회
- 하진실, "초등학생 가정을 대상으로 한 바이오에어로졸 노출과 아토피와의 연관성 평가", 한국환경보건학회지, 37(6), pp.406~417 (2011), 한국환경보건학회
- 권순박, "KTX 객실내 부유미생물 오염현황 조사", 한국실내환경학회지, 8(1), pp.11~19 (2011), 한국실내환경학회
- Choi SW, "Reliability and validity of the Korean version of ISAAC Questionnaire", Korean J Prev Med, 31(3), pp.361~371 (1998)
- 김기연, "종합병원의 실내공기에 분포하는 부유 세균과 진균의 입경별 종류와 특성", 한국산업위생학회지, 16(2), pp.101~109 (2006), 한국산업보건학회
- 김윤신, "다중이용시설에서의 실내공기 중 미생물 분포에 관한 연구", 한국환경보건학회지, 28(1), pp.85~92 (2002), 한국환경보건학회
- 황성호, "일부 대학교 미생물실험실 및 화학실험실에서의 진균 분포 및 관련인자", 한국산업위생학회지, 20(1), pp.41~46 (2010), 한국산업보건학회
- 김명운, "실내환경에서의 미생물 오염도 평가 및 정도관리 방안", 한국실내환경학회지, 9(2), pp.161~171 (2012), 한국실내환경학회[DOI]
- de Aquino Neto FR, "Guidelines for indoor air quality in offices in Brazil", Proceedings of Healthy Buildings, 4, pp.549~554 (2000)
- Lee T, "Culturability and concentration of indoor and outdoor airborne fungi in six single-family homes", Atmos Environ, 40(16), pp.2902~2910 (2006)
- 박주형, "실내환경에서 생물학적 인자에 대한 노출평가", 한국환경보건학회지, 35(4), pp.239~248 (2009), 한국환경보건학회
- Chen C, "Review of relationship between indoor and outdoor particles: I", O ratio, infiltration factor and penetration factor, 2011, pp.45(2), 275~288
- Araki A, "The relationship between exposure to microbial volatile organic compound and allergy prevalence in single-family homes", Sci Total Environ, 423, pp.18~26 (2012)
- Akpinar-Elci M, "Markers of upper airway inflammation associated with microbial exposure and symptoms in occupants of a waterdamaged building", Am J Ind Med, 56(5), pp.522~530 (2013)
- Sordillo JE, "Home characteristics as predictors of bacterial and fungal microbial biomarkers in house dust", Environmental Health Perspectives, 119(2), pp.189~195 (2011)
- Jaakkola JJ, "Home dampness and molds as determinants of allergic rhinitis in childhood: a 6-year, population-based cohort study", Am J Epidemiol, 172(4), pp.451~459 (2010)
- Saijo Y, "Relationships between mite allergen levels, mold concentrations, and sick building syndrome symptoms in newly built dwellings in Japan", Indoor air, 21(3), pp.253~263 (2011)
- O'connor GT, "Airborne fungi in the homes of children with asthma in low-income urban communities: The Inner-City Asthma Study", J Allergy Clin Immunol, 114(3), pp.599~606 (2004)
- 김호현, "어린이 천식환자에 대한 실내외 환경 노출 특성 평가", 한국실내환경학회지, 5(2), pp.106~121 (2008), 한국실내환경학회