PC 방 금연구역의 간접흡연 노출

Secondhand Smoke Exposure in Commercial Personal Computer Rooms

0

조회

0

다운로드

13

인용

0

참고문헌

키워드

초록

In this study, exposure to secondhand smoke (SHS) was evaluated in commercial personal computer (PC) rooms with different separation types of non-smoking areas. The particulate matter less than 2.5 μm (PM2.5) level was simultaneously measured by aerosol spectrometers in the non-smoking and smoking areas of these commercial PC rooms. Average PM2.5 concentrations in non-smoking and smoking areas were 75 μg/m3 and 136 μg/m3, respectively. Although the PM2.5 concentrations in non-smoking areas were significantly less than those in smoking areas (p<0.01), the levels still exceeded the US National Ambient Air Quality Standard of 35 μg/m3. Average PM2.5 concentrations in non-smoking areas were not significantly different with regard to area separation type, with 73 μg/m3 in the no-wall type, 83 μg/m3 in the wall-type, and 39 μg/m3 in the separated-floor-type areas (p>0.1). Separation of the non-smoking area thus did not eliminate SHS exposure in commercial PC rooms, regardless of the type of area separation. This study demonstrates that simple separation of non-smoking areas in commercial PC rooms does not protect users from SHS.

Abstract

In this study, exposure to secondhand smoke (SHS) was evaluated in commercial personal computer (PC) rooms with different separation types of non-smoking areas. The particulate matter less than 2.5 μm (PM2.5) level was simultaneously measured by aerosol spectrometers in the non-smoking and smoking areas of these commercial PC rooms. Average PM2.5 concentrations in non-smoking and smoking areas were 75 μg/m3 and 136 μg/m3, respectively. Although the PM2.5 concentrations in non-smoking areas were significantly less than those in smoking areas (p<0.01), the levels still exceeded the US National Ambient Air Quality Standard of 35 μg/m3. Average PM2.5 concentrations in non-smoking areas were not significantly different with regard to area separation type, with 73 μg/m3 in the no-wall type, 83 μg/m3 in the wall-type, and 39 μg/m3 in the separated-floor-type areas (p>0.1). Separation of the non-smoking area thus did not eliminate SHS exposure in commercial PC rooms, regardless of the type of area separation. This study demonstrates that simple separation of non-smoking areas in commercial PC rooms does not protect users from SHS.

참고문헌 (18)

  1. "International Agency for Research on Cancer. IARC monographs on the evaluation of carcinogenic risk to humans : Tobacco smoke and involuntary smoking" (2004), International Agency for Research on Cancer
  2. "National Research Council. Environmental tobacco smoke : Measuring exposures and assessing health effects" (1986), National Academy Press
  3. U.S Department of Health and Humans Services. The health consequences of involuntary smoking, , A report of the surgeon general, ~ (1986)
  4. US EPA. Respiratory health effects of passive smoking: lung cancer and other disorders; Technical Report EPA, "600", 6-90, pp.Office of Research and Development, 1992[DOI]
  5. Taylor, A. E, "Environmental tobacco smoke and cardiovascular disease.A position paper from the Council on Cardiopulmonary and Critical Care, American Heart Association", Circulation, 86(2), pp.699~702 (1992)
  6. Glantz,S.A, "Passive smoking and heart disease. Mechanism and risk", Journal of the American Medical Association, 273(13), pp.1047~1053 (1995)
  7. Law, M. R, "Environmental tobacco smoke exposure and ischaemic heart disease: an evaluation of the evidence", British Medical Journal, 315(7114), pp.973~980 (1997)
  8. "California Environmental Protection Agency : Proposed identification of environmental tobacco smoke as a toxic air contaminant", Health effects. Sacramento, California, USA: California Environmental Protection Agency, office of Environmental Health Hazard Assessment, ~ (2005)
  9. World Health Organization : International consultation on environmental tobacco smoke (ETS) and child health, , Consultation Report. Geneva, Switzerland:World Health Organization, ~ (1999)
  10. "World Health Organization : Only 100% smoke-free environments adequately protect from danger of second-hand smoke", New WHO policy recommendations point to extensive evidence, ~ (2007)
  11. Mannino, D. M, "Involuntary smoking and asthma severity in children:data from the third national health and nutrition examination survey", Chest, 122, pp.309~415 (2002)
  12. "Institute of Medicine Clearing the air : Asthma and indoor air exposures" (2000), National Academy Press
  13. Yolton, K, "Exposure to environmental tobacco smoke and cognitive abilities among U.S. children and adolescents", Environmental Health Perspectives, 113(1), pp.98~103 (2005)
  14. Lee K, "Differential impact of smokefree laws on indoor air quality", Journal of Environmental Health, 70(8), pp.24~30 (2008)
  15. Lambert, W. E, "Environmental tobacco-smoke concentrations in nosmoking and smoking sections of restaurants", American Journal of Public Health, 83(10), pp.1399~ (1993)
  16. Brauer,M, "Restaurant smoking restrictions and environmental tobacco smoke exposure", American Journal of Public Health, 88(12), pp.1834~1836 (1998)
  17. Lee, K, "Immediate impact of smoke-free laws on indoor air quality", Southern Medical Journal, 100(9), pp.885~889 (2007)
  18. US Department of Health and Human Services : The health consequences of involuntary exposure to tobacco smoke: a report of the Surgeon General, , US Department of Health and Human Services, Centers for Disease Control and Prevention, Coordinating Center for Health Promotion, National Center for Chronic Disease Prevention and Health Promotion, Office on Smoking and Health, ~ (2006)

관련 논문AI추천

이 간행물의 다른 논문 (9건)