Objectives: This study examined the impact of a smoke-free policy on indoor air quality at indoor recreation facilities by assessing PM 2.5 concentrations before and after the implementation of the new policy. Methods: Using real-time monitors, PM 2.5 concentrations were measured in 50 billiard rooms and 50 golf simulator rooms in Seoul, Korea. The characteristics of the indoor recreation facilities, smoking status, and atmospheric conditions were recorded at the same time.After the enforcement of a smoke-free policy, PM 2.5 concentrations, installation of smoking room, and smoking status were examined when the facilities were revisited. Results: Almost a half of the billiard rooms and over 80% of golf simulator rooms were located underground. Seventy percent of the billiard rooms and one hundred percent of the golf simulator rooms were equipped with a local exhaust ventilation system. After the implementation of the smoke-free policy, 46% of the billiard rooms and 20% of the golf simulator rooms newly installed a smoking room. In the billiard rooms with a newlyinstalled smoking room, the PM 2.5 concentrations decreased from 97.9 to 45.6 µg/m 3 after the implementation of the smoke-free policy. The same change of 29.0 to 26.3 µg/m 3 was not statistically significant in golf simulator rooms. Indoor PM 2.5 concentrations were correlated with outdoor PM 2.5 concentrations, number of smokers, and number of people in the room. Conclusions: The smoke-free policy forindoor recreationfacilities was not effective atmaking the indoor spaces free fromsecondhand smoke. Although a few billiard rooms installed a smoking room, indoor PM 2.5 concentrations were still higher than those of outdoor PM 2.5 or atmospheric PM 2.5 . Stricter enforcement of the smoke-free policy should be achieved to prevent secondhand smoke exposure.

Abstract

Objectives: This study examined the impact of a smoke-free policy on indoor air quality at indoor recreation facilities by assessing PM 2.5 concentrations before and after the implementation of the new policy. Methods: Using real-time monitors, PM 2.5 concentrations were measured in 50 billiard rooms and 50 golf simulator rooms in Seoul, Korea. The characteristics of the indoor recreation facilities, smoking status, and atmospheric conditions were recorded at the same time.After the enforcement of a smoke-free policy, PM 2.5 concentrations, installation of smoking room, and smoking status were examined when the facilities were revisited. Results: Almost a half of the billiard rooms and over 80% of golf simulator rooms were located underground. Seventy percent of the billiard rooms and one hundred percent of the golf simulator rooms were equipped with a local exhaust ventilation system. After the implementation of the smoke-free policy, 46% of the billiard rooms and 20% of the golf simulator rooms newly installed a smoking room. In the billiard rooms with a newlyinstalled smoking room, the PM 2.5 concentrations decreased from 97.9 to 45.6 µg/m 3 after the implementation of the smoke-free policy. The same change of 29.0 to 26.3 µg/m 3 was not statistically significant in golf simulator rooms. Indoor PM 2.5 concentrations were correlated with outdoor PM 2.5 concentrations, number of smokers, and number of people in the room. Conclusions: The smoke-free policy forindoor recreationfacilities was not effective atmaking the indoor spaces free fromsecondhand smoke. Although a few billiard rooms installed a smoking room, indoor PM 2.5 concentrations were still higher than those of outdoor PM 2.5 or atmospheric PM 2.5 . Stricter enforcement of the smoke-free policy should be achieved to prevent secondhand smoke exposure.

참고문헌 (15)

  1. Environmental Protection Agency, "Health Effects of Exposure to Secondhand Smoke" (2015)
  2. Pitsavos C, "Association between exposure to environmental tobacco smoke and the development of acute coronary syndromes: the CARDIO2000 case-control study", Tobacco Control, 11(3), pp.220~225 (2002)[DOI]
  3. Brennan P, "Secondhand smoke exposure in adulthood and risk of lung cancer among never smokers: a pooled analysis of two large studies", International Journal of Cancer, 109(1), pp.125~131 (2004)[DOI]
  4. Sturm JJ, "Effects of tobacco smoke exposure on asthma prevalence and medical care use in North Carolina middle school children", American Journal of Public Health, 94(2), pp.308~313 (2004)[DOI]
  5. USDHHS, "How tobacco smoke causes disease: the biology and behavioral basis for smoking-attributable disease: a report of the Surgeon General" (2010)
  6. 황규석, "서울시내 PC방에서의 환경성담배연기(ETS) 농도에 관한 연구", 한국환경보건학회지, 29(3), pp.43~49 (2003), 한국환경보건학회
  7. Lee K, "Differential impacts of smoke-free laws on indoor air quality", Journal of Environmental Health, 70(8), pp.24~30 (2008)
  8. 김정훈, "서울시내 PC 방의 금연정책 시행 전과 후의 실내 PM2.5 농도 변화", 실내환경 및 냄새 학회지, 14(1), pp.1~6 (2015), 한국냄새환경학회[DOI]
  9. Kim HJ, "Compliance of Indoor Smoke-free Regulation in Internet Cafes of Seoul, Korea", Journal of the Korean Society for Research on Nicotine and Tobacco, 7(1), pp.12~18 (2016)[DOI]
  10. Suh MK, "The recent international trends of smoke-free policies: Canada, Singapole, USA", Health-welfare Policy Forum, 176, pp.72~29 (2011)
  11. Semple S, "Secondhand smoke levels in Scottish pubs: the effect of smoke-free legislation", Tobacco Control, 16(2), pp.127~132 (2007)[DOI]
  12. Ministry of Health and Welfare, "Prohibiting smoking in billiard room and screen golf course from December 3rd", Announcement from Ministry of Health and Welfare, ~ (2017)
  13. 곽수영, "금연정책 시행이 전국 PC방의 간접흡연에 미치는 영향", 한국환경보건학회지, 41(1), pp.11~16 (2015), 한국환경보건학회[DOI]
  14. Lee K, "Air quality in and around airport enclosed smoking rooms", Nicotine & Tobacco Research, 12(6), pp.665~668 (2010)[DOI]
  15. Pion M, "Airport smoking rooms don't work", Tobacco Control, 13(suppl 1), pp.i37~i40 (2004)[DOI]