Background: This study evaluated the radon contribution rate through an evaluation of the exhalation rate of radon from building materials. Objectives: This study compared and evaluated the computation of the radon contribution rate based on each different exhalation rate in a building. Methods: The six demonstration houses that are the subject of this study are wall structures or Rahmen structures, and include demonstration houses similar to general residential environments and non-finishing houses with some walls exposed. Results: The highest exhalation rate was found at 62.98 Bq/m2 per day from the non–finishing floor, and the second highest exhalation rate was from stone materials at 58.76 Bq/m2 per day. Based on this result, investigating the contribution rate of building materials derived from building materials among indoor radon concentrations, house three was the highest at 81.7%, and house one was confirmed to be 33.96%. Conclusions: It can be judged that the effect of exposed concrete and stone is high, and that it is possible to reduce radon emitted from indoor building structures by controlling the indoor materials.
Abstract
Background: This study evaluated the radon contribution rate through an evaluation of the exhalation rate of radon from building materials. Objectives: This study compared and evaluated the computation of the radon contribution rate based on each different exhalation rate in a building. Methods: The six demonstration houses that are the subject of this study are wall structures or Rahmen structures, and include demonstration houses similar to general residential environments and non-finishing houses with some walls exposed. Results: The highest exhalation rate was found at 62.98 Bq/m2 per day from the non–finishing floor, and the second highest exhalation rate was from stone materials at 58.76 Bq/m2 per day. Based on this result, investigating the contribution rate of building materials derived from building materials among indoor radon concentrations, house three was the highest at 81.7%, and house one was confirmed to be 33.96%. Conclusions: It can be judged that the effect of exposed concrete and stone is high, and that it is possible to reduce radon emitted from indoor building structures by controlling the indoor materials.
참고문헌 (14)
- International Agency for Research on Cancer, "Man-Made Mineral Fibres and Radon: Views and Expert Opinions of an IARC Working Group on the Evaluation of Carcinogenic Risks to Humans" (1988), IARC
- United States, "Environmental Protection Agency. Technical Support Document for the 1992 Citizen’s Guide to Radon", pp.2~37 (1992), U.S. Environmental Protection Agency
- United States. Environmental Protection Agency, "Indoor Radon and Radon Decay Product Measurement Device Protocols", pp.9~23 (1992), U.S. Environmental Protection Agency
- "United Nations Scientific Committee on the Effects of Atomic Radiation. Sources and Effects of Ionizing Radiation"[URL]
- "Health Risk of Radon"[URL]
- Gregory B, "National Radon Results: 1985 to 2003", pp.1~7 (2004), U.S. Environmental Protection Agency
- Zeeb H, "WHO Handbook on Indoor Radon : a Public Health Perspective", World Health Organization, 21~35 (2009)
- United Nations, "Effects of Ionizing Radiation", pp.197~334 (2009), United Nations Publication
- Saad AF, "Radon exhalation rate from building materials used on the Garyounis University campus, Benghazi, Libya", Turkish J Eng Environ Sci, 34(1), pp.67~74 (2010)
- Haquin G, "Natural radioactivity and radon in building materials", 12th Congress of the International Radiation Protection Association; 2008 (2010), International Atomic Energy Agency
- Kotrappa P, "Electret ion chambers(eic)to measure radon exhalation rates from building materials", Proceedings of the American Association of Radon Scientists and Technologists 2008 International Symposium, pp.11~18 (2008), AARS
- Keller G, "Radon permeability and radon exhalation of building materials", Sci Total Environ, 272, pp.85~89 (2001)
- 이철민, "국내 다양한 실내환경 내 라돈농도 및 거주자의 실효선량 평가", 한국환경보건학회지, 33(4), pp.264~275 (2007), 한국환경보건학회
- Chen J, "Radon exhalation from building materials for decorative use", J Environ Radioact, 101(4), pp.317~322 (2010)