서울시 관악구 도림천 복개 정도에 따른 환경 악취 요인 분석
Analysis of Environmental Odor Factors for Dorim Stream in Gwanak-gu, Seoul
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: In this study, we investigate the rapid increase in environmental odors and notable rise in civil complaints near Dorim Stream in the Gwanak-gu area of Seoul. Objectives: This study aims to identify the causal compounds responsible for environmental odors in the Dorim Stream and investigate the structural characteristics of the stream that inf luence odor generation. Methods: The research methodology involved setting up 41 sampling points, selecting panels for direct sensory evaluation to assess odor intensity, measuring dissolved oxygen and hydrogen sulfide concentrations, and using all-in-one low-temperature desorption gas chromatography (ATD-GC) and thermal desorption- gas chromatography-mass spectrometry (TD-GC/MS) analysis to identify odor-causing compounds. Results: The evaluation of Dorim Stream revealed that in areas with complete meandering, there were lower dissolved oxygen levels (4.5±2.67 mg/L) and higher odor intensity (4.0±0.92), while in partially meandering sections, higher dissolved oxygen levels (7.8±1.15 mg/L) and lower odor intensity (2.8±1.06) were observed. Hydrogen sulfide levels measured with sensors increased with higher temperatures, especially in the afternoon hours (12:00~14:00). Acetaldehyde was the dominant odor compound detected in both the Bonglim Bridge (0.4 ppm) area and Guro Bridge area (0.867 ppm), with concentrations more than twice as high near Guro Bridge. Odor-causing compounds identified by TD-GC/MS indicated a pungent, sulfurous odor in the Guro Bridge area and a musty odor in the Bonglim Bridge area. Conclusions: This study categorizes and analyzes the sources of odor in Dorim Stream in Seoul based on meandering patterns and the distribution of sewage facilities, highlighting the potential odor issues associated with combined sewage systems and sewer junctions and suggesting policy improvements.
Abstract
Background: In this study, we investigate the rapid increase in environmental odors and notable rise in civil complaints near Dorim Stream in the Gwanak-gu area of Seoul. Objectives: This study aims to identify the causal compounds responsible for environmental odors in the Dorim Stream and investigate the structural characteristics of the stream that inf luence odor generation. Methods: The research methodology involved setting up 41 sampling points, selecting panels for direct sensory evaluation to assess odor intensity, measuring dissolved oxygen and hydrogen sulfide concentrations, and using all-in-one low-temperature desorption gas chromatography (ATD-GC) and thermal desorption- gas chromatography-mass spectrometry (TD-GC/MS) analysis to identify odor-causing compounds. Results: The evaluation of Dorim Stream revealed that in areas with complete meandering, there were lower dissolved oxygen levels (4.5±2.67 mg/L) and higher odor intensity (4.0±0.92), while in partially meandering sections, higher dissolved oxygen levels (7.8±1.15 mg/L) and lower odor intensity (2.8±1.06) were observed. Hydrogen sulfide levels measured with sensors increased with higher temperatures, especially in the afternoon hours (12:00~14:00). Acetaldehyde was the dominant odor compound detected in both the Bonglim Bridge (0.4 ppm) area and Guro Bridge area (0.867 ppm), with concentrations more than twice as high near Guro Bridge. Odor-causing compounds identified by TD-GC/MS indicated a pungent, sulfurous odor in the Guro Bridge area and a musty odor in the Bonglim Bridge area. Conclusions: This study categorizes and analyzes the sources of odor in Dorim Stream in Seoul based on meandering patterns and the distribution of sewage facilities, highlighting the potential odor issues associated with combined sewage systems and sewer junctions and suggesting policy improvements.
참고문헌 (17)
- Sucker K, "Odor frequency and odor annoyance. Part I: assessment of frequency, intensity and hedonic tone of environmental odors in the field", Int Arch Occup Environ Health, 81(6), pp.671~682 (2008)
- A study on the characteristics of odors by industrial classification, "Kim SY", Busan Inst. Health Environ, 21~40, pp.Rep. Busan Inst. Health Environ;14 (2004)
- The analytical method of S gas: evaluation of loss rate associated sampling procedure, "Choi YJ", Korean Society for Atmospheric Environment, 336~337 (2005)
- Piccardo MT, "Odor emissions : a public health concern for health risk perception", Environ Res, 204, pp.112121~ (2022)
- "2021 environmental white paper, Seoul’s environment"[URL]
- "2020 Gwanak-gu regular public opinion poll results report"[URL]
- "Dorim stream"[URL]
- "Current status of sewage pipes in Seoul"[URL]
- European Committee for Standardization, "EN 13725 2003: air quality-determination of odour concentration by dynamic olfactometry", CEN, ~ (2003)
- "Standard test method for odor in water"[URL]
- "Korea Law Information Center. Odor process test standards"[URL]
- "Korea Law Information Center. Water pollution process test standards"[URL]
- GASTEC, "The manual of GHS-8AT", GASTEC, ~ (2012)
- GASTEC, "The manual of ANASYS·Software", GASTEC, ~ (2012)
- Sparkman OD, "Gas chromatography and mass spectrometry: a practical guide", pp.2~13 (2011), Academic Press
- Majchrzak T, "PTR-MS and GC-MS as complementary techniques for analysis of volatiles : a tutorial review", Anal Chim Acta, 1035, pp.1~13 (2018)
- "Automatic weather system"[URL]