Development of Personalized Urination Recognition Technology Using Smart Bands
0
조회
0
다운로드
7
인용
0
참고문헌
키워드
초록
Purpose: This study collected and analyzed activity data sensed through smart bands worn by patients in order to resolve the clinical issues posed by using voiding charts. By developing a smart band-based algorithm for recognizing urination activity in patients, this study aimed to explore the feasibility of urination monitoring systems. Methods: This study aimed to develop an algorithm that recognizes urination based on a patient’s posture and changes in posture. Motion data was obtained from a smart band on the arm. An algorithm that recognizes the 3 stages of urination (forward movement, urination, backward movement) was developed based on data collected from a 3-axis accelerometer and from tilt angle data. Real-time data were acquired from the smart band, and for data corresponding to a certain duration, the absolute value of the signals was calculated and then compared with the set threshold value to determine the occurrence of vibration signals. In feature extraction, the most essential information describing each pattern was identified after analyzing the characteristics of the data. The results of the feature extraction process were sorted using a classifier to detect urination. Results: An experiment was carried out to assess the performance of the recognition technology proposed in this study. The final accuracy of the algorithm was calculated based on clinical guidelines for urologists. The experiment showed a high average accuracy of 90.4%, proving the robustness of the proposed algorithm. Conclusions: The proposed urination recognition technology draws on acceleration data and tilt angle data collected via a smart band; these data were then analyzed using a classifier after comparative analyses with standardized feature patterns.
Abstract
Purpose: This study collected and analyzed activity data sensed through smart bands worn by patients in order to resolve the clinical issues posed by using voiding charts. By developing a smart band-based algorithm for recognizing urination activity in patients, this study aimed to explore the feasibility of urination monitoring systems. Methods: This study aimed to develop an algorithm that recognizes urination based on a patient’s posture and changes in posture. Motion data was obtained from a smart band on the arm. An algorithm that recognizes the 3 stages of urination (forward movement, urination, backward movement) was developed based on data collected from a 3-axis accelerometer and from tilt angle data. Real-time data were acquired from the smart band, and for data corresponding to a certain duration, the absolute value of the signals was calculated and then compared with the set threshold value to determine the occurrence of vibration signals. In feature extraction, the most essential information describing each pattern was identified after analyzing the characteristics of the data. The results of the feature extraction process were sorted using a classifier to detect urination. Results: An experiment was carried out to assess the performance of the recognition technology proposed in this study. The final accuracy of the algorithm was calculated based on clinical guidelines for urologists. The experiment showed a high average accuracy of 90.4%, proving the robustness of the proposed algorithm. Conclusions: The proposed urination recognition technology draws on acceleration data and tilt angle data collected via a smart band; these data were then analyzed using a classifier after comparative analyses with standardized feature patterns.
참고문헌 (16)
- Klevmark B, "Natural pressure-volume curves and conventional cystometry", Scand J Urol Nephrol Suppl, 201, pp.1~4 (1999)
- McGuire EJ, "Videourodynamic studies", Urol Clin North Am, 23, pp.309~321 (1996)
- Abrams P, "The standardisation of terminology of lower urinary tract function : report from the Standardisation Sub-committee of the International Continence Society", Neurourol Urodyn, 21, pp.167~178 (2002)
- Jarvis GJ, "An assessment of urodynamic examination in incontinent women", Br J Obstet Gynaecol, 87, pp.893~896 (1980)
- Webb RJ, "Electromyographic abnormalities in the urethral and anal sphincters of women with idiopathic retention of urine", Br J Urol, 70, pp.22~25 (1992)
- Kim SH, "Voiding diary might serve as a useful tool to understand differences between bladder pain syndrome", interstitial cystitis and overactive bladder, 2014, pp.21, 179~183
- Ku JH, "Voiding diary for the evaluation of urinary incontinence and lower urinary tract symptoms : prospective assessment of patient compliance and burden", Neurourol Urodyn, 23, pp.331~335 (2004)
- Burgio KL, "Behavioral vs drug treatment for urge urinary incontinence in older women : a randomized controlled trial", JAMA, 280, pp.1995~2000 (1998)
- 김성은, "Effects of Tamsulosin on Urinary Bladder Function and Neuronal Activity in the Voiding Centers of Rats with Cyclophosphamide-induced Overactive Bladder", International Neurourology Journal, 16(1), pp.13~22 (2012), 대한배뇨장애요실금학회
- 노종윤, "Circadian Rhythms in Urinary Functions: Possible Roles of Circadian Clocks?", International Neurourology Journal, 15(2), pp.64~73 (2011), 대한배뇨장애요실금학회
- Jung DJ, "A study on the development of a long-term data collection device to establish fall detection algorithms", 2014 Institute of Electronics and Information Engineers Fall Meeting, pp.600~603 (2014), The Institute of Electronics and Information Engineers
- 류정탁, "3축 가속도센서와 기울기 센서를 이용한 낙상감지시스템 개발", 한국산업정보학회논문지, 18(4), pp.19~24 (2013), 한국산업정보학회[DOI]
- 김남섭, "유비쿼터스 헬스케어를 위한 효율적인 낙상 감지 기법", 한국정보기술학회논문지, 8(8), pp.133~140 (2010), 한국정보기술학회
- 김상수, "움직임 벡터를 이용한 낙상 감지 시스템", 한국정보전자통신기술학회 논문지, 9(1), pp.38~44 (2016), 한국정보전자통신기술학회
- Ben-Hur A, "Support vector machines and kernels for computational biology", PLoS Comput Biolo, 4, pp.e10000173~ (2008)
- 이창기, "Recurrent Neural Network를 이용한 이미지 캡션 생성", 정보과학회논문지, 43(08), pp.878~882 (2016), 한국정보과학회