본문 바로가기
KERD
논문KCI 등재

Personalized Urination Activity Recognition Based on a Recurrent Neural Network Using Smart Band

1

조회

0

다운로드

10

인용

0

참고문헌

키워드

초록

Purpose: Though it is very important obtaining exact data about patients’ voiding patterns for managing voiding dysfunction, actual practice is very difficult and cumbersome. In this study, data about urination time and interval measured by smart band device on patients’ wrist were collected and analyzed to resolve the clinical arguments about the efficacy of voiding diary. By developing a smart band based algorithm for recognition of complex and serial pattern of motion, this study aimed to explore the feasibility of measurement the urination time and intervals for voiding dysfunction management. Methods: We designed a device capable of recognizing urination time and intervals based on specific postures of the patient and consistent changes in posture. These motion data were obtained by a smart band worn on the wrist. An algorithm that recognizes the repetitive and common 3-step behavior for urination (forward movement, urination, backward movement) was devised based on the movement and tilt angle data collected from a 3-axis accelerometer. The sequence of body movements during voiding has consistent temporal characteristics, so we used a recurrent neural network and long short-term memory based framework to analyze the sequential data and to recognize urination time. Real-time data were acquired from the smart band, and for data corresponding to a certain duration, the value of the signals was calculated and then compared with the set analysis model to calculate the time of urination. A comparative study was conducted between real voiding and device-detected voiding to assess the performance of the proposed recognition technology. Results: The accuracy of the algorithm was calculated based on clinical guidelines established by urologists. The accuracy of this detecting device was high (up to 94.2%), proving the robustness of the proposed algorithm. Conclusions: This urination behavior recognition technology showed high accuracy and could be applied in clinical settings to characterize patients’ voiding patterns. As wearable devices are developed and generalized, algorithms detecting consistent sequential body movement patterns reflecting specific physiologic behavior might be a new methodology for studying human physiologic behavior.

Abstract

Purpose: Though it is very important obtaining exact data about patients’ voiding patterns for managing voiding dysfunction, actual practice is very difficult and cumbersome. In this study, data about urination time and interval measured by smart band device on patients’ wrist were collected and analyzed to resolve the clinical arguments about the efficacy of voiding diary. By developing a smart band based algorithm for recognition of complex and serial pattern of motion, this study aimed to explore the feasibility of measurement the urination time and intervals for voiding dysfunction management. Methods: We designed a device capable of recognizing urination time and intervals based on specific postures of the patient and consistent changes in posture. These motion data were obtained by a smart band worn on the wrist. An algorithm that recognizes the repetitive and common 3-step behavior for urination (forward movement, urination, backward movement) was devised based on the movement and tilt angle data collected from a 3-axis accelerometer. The sequence of body movements during voiding has consistent temporal characteristics, so we used a recurrent neural network and long short-term memory based framework to analyze the sequential data and to recognize urination time. Real-time data were acquired from the smart band, and for data corresponding to a certain duration, the value of the signals was calculated and then compared with the set analysis model to calculate the time of urination. A comparative study was conducted between real voiding and device-detected voiding to assess the performance of the proposed recognition technology. Results: The accuracy of the algorithm was calculated based on clinical guidelines established by urologists. The accuracy of this detecting device was high (up to 94.2%), proving the robustness of the proposed algorithm. Conclusions: This urination behavior recognition technology showed high accuracy and could be applied in clinical settings to characterize patients’ voiding patterns. As wearable devices are developed and generalized, algorithms detecting consistent sequential body movement patterns reflecting specific physiologic behavior might be a new methodology for studying human physiologic behavior.

참고문헌 (22)

  1. Klevmark B, "Natural pressure-volume curves and conventional cystometry", Scand J Urol Nephrol Suppl, 201, pp.1~4 (1999)
  2. McGuire EJ, "Videourodynamic studies", Urol Clin North Am, 23, pp.309~321 (1996)[DOI]
  3. Abrams P, "The standardisation of terminology of lower urinary tract function: report from the Standardisation Sub-committee of the International Continence Society", Neurourol Urodyn, 21, pp.167~178 (2002)[DOI]
  4. Jarvis GJ, "An assessment of urodynamic examination in incontinent women", Br J Obstet Gynaecol, 87, pp.893~896 (1980)[DOI]
  5. Webb RJ, "Electromyographic abnormalities in the urethral and anal sphincters of women with idiopathic retention of urine", Br J Urol, 70, pp.22~25 (1992)
  6. Kim SH, "Voiding diary might serve as a useful tool to understand differences between bladder pain syndrome", interstitial cystitis and overactive bladder, 2014, pp.21, 179~183
  7. Haykin S, "Neural networks: a comprehensive foundation" (1994), MacMillan
  8. Fraley C, "Model-based clustering, discriminant analysis, and density estimation", J Am Stat Assoc, 97, pp.611~631 (2002)[DOI]
  9. Berndt DJ, "Using dynamic time warping to find patterns in time series", Proceeding AAAIWS'94 Proceedings of the 3rd International Conference on Knowledge Discovery and Data Mining, pp.359~370 (1994)
  10. Murphy KP, "Dynamic bayesian networks: representation, inference and learning", pp.2002
  11. Sonnhammer EL, "A hidden Markov model for predicting transmembrane helices in protein sequences", Proc Int Conf Intell Syst Mol Biol, 6, pp.175~182 (1998)
  12. LeCun Y, "Deep learning", Nature, 521, pp.436~444 (2015)[DOI]
  13. Greff K, "LSTM: a search space odyssey", IEEE Trans Neural Netw Learn Syst, 28, pp.2222~2232 (2017)[DOI]
  14. 은성종, "Development of Personalized Urination Recognition Technology Using Smart Bands", International Neurourology Journal, 21, pp.76~83 (2017), 대한배뇨장애요실금학회
  15. Simard PY, "Best practices for convolutional neural networks applied to visual document analysis", Proceedings of the Seventh International Conference on Document Analysis and Recognition (ICDAR 2003), pp.958~962 (2003), Institute of Electrical and Electronics Engineers
  16. Ku JH, "Voiding diary for the evaluation of urinary incontinence and lower urinary tract symptoms: prospective assessment of patient compliance and burden", Neurourol Urodyn, 23, pp.331~335 (2004)[DOI]
  17. Burgio KL, "Behavioral vs drug treatment for urge urinary incontinence in older women: a randomized controlled trial", JAMA, 280, pp.1995~2000 (1998)[DOI]
  18. 김성은, "Effects of Tamsulosin on Urinary Bladder Function and Neuronal Activity in the Voiding Centers of Rats with Cyclophosphamide-induced Overactive Bladder", International Neurourology Journal, 16(1), pp.13~22 (2012), 대한배뇨장애요실금학회
  19. 노종윤, "Circadian Rhythms in Urinary Functions: Possible Roles of Circadian Clocks?", International Neurourology Journal, 15(2), pp.64~73 (2011), 대한배뇨장애요실금학회
  20. Valente F, "Combination of acoustic classifiers based on Dempster-Shafer theory of evidence", IEEE International Conference on Acoustics, Speech and Signal Processing - ICASSP '07 (2007)
  21. Liwicki M, "A novel approach to on-line handwriting recognition based on bidirectional long short-term memory networks", ICDAR '07 Proceedings of the Ninth International Conference on Document Analysis and Recognition (2007), IEEE Computer Society
  22. Vapnik V, "Support vector method for multivariate density estimation", Adv Neural Inf Process Syst, pp.659~665 (2000)

관련 논문AI추천

이 간행물의 다른 논문 (12건)