Realistic Electric Field Mapping of Anisotropic Muscle During Electrical Stimulation Using a Combination of Water Diffusion Tensor and Electrical Conductivity

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

Purpose: To realistically map the electric fields of biological tissues using a diffusion tensor magnetic resonance electrical impedance tomography (DT-MREIT) method to estimate tissue response during electrical stimulation. Methods: Imaging experiments were performed using chunks of bovine muscle. Two silver wire electrodes were positioned inside the muscle tissue for electrical stimulation. Electric pulses were applied with a 100-V amplitude and 100-μs width using a voltage stimulator. During electrical stimulation, we collected DT-MREIT data from a 3T magnetic resonance imaging scanner. We adopted the projected current density method to calculate the electric field. Based on the relation between the water diffusion tensor and the conductivity tensor, we computed the position-dependent scale factor using the measured magnetic flux density data. Then, a final conductivity tensor map was reconstructed using the multiplication of the water diffusion tensor and the scale factor. Results: The current density images from DT-MREIT data represent the internal current flows that exist not only in the electrodes but also in surrounding regions. The reconstructed electric filed map from our anisotropic conductivity tensor with the projected current density shows coverage that is more than 2 times as wide, and higher signals in both the electrodes and surrounding tissues, than the previous isotropic method owing to the consideration of tissue anisotropy. Conclusions: An electric field map obtained by an anisotropic reconstruction method showed different patterns from the results of the previous isotropic reconstruction method. Since accurate electric field mapping is important to correctly estimate the coverage of the electrical treatment, future studies should include more rigorous validations of the new method through in vivo and in situ experiments.

Abstract

Purpose: To realistically map the electric fields of biological tissues using a diffusion tensor magnetic resonance electrical impedance tomography (DT-MREIT) method to estimate tissue response during electrical stimulation. Methods: Imaging experiments were performed using chunks of bovine muscle. Two silver wire electrodes were positioned inside the muscle tissue for electrical stimulation. Electric pulses were applied with a 100-V amplitude and 100-μs width using a voltage stimulator. During electrical stimulation, we collected DT-MREIT data from a 3T magnetic resonance imaging scanner. We adopted the projected current density method to calculate the electric field. Based on the relation between the water diffusion tensor and the conductivity tensor, we computed the position-dependent scale factor using the measured magnetic flux density data. Then, a final conductivity tensor map was reconstructed using the multiplication of the water diffusion tensor and the scale factor. Results: The current density images from DT-MREIT data represent the internal current flows that exist not only in the electrodes but also in surrounding regions. The reconstructed electric filed map from our anisotropic conductivity tensor with the projected current density shows coverage that is more than 2 times as wide, and higher signals in both the electrodes and surrounding tissues, than the previous isotropic method owing to the consideration of tissue anisotropy. Conclusions: An electric field map obtained by an anisotropic reconstruction method showed different patterns from the results of the previous isotropic reconstruction method. Since accurate electric field mapping is important to correctly estimate the coverage of the electrical treatment, future studies should include more rigorous validations of the new method through in vivo and in situ experiments.

참고문헌 (24)

  1. Yarmush ML, "Electroporation-based technologies for medicine: principles, applications, and challenges", Annu Rev Biomed Eng, 16, pp.295~320 (2014)
  2. Miklavcic D, "The importance of electric field distribution for effective in vivo electroporation of tissues", Biophys J, 74, pp.2152~2158 (1998)
  3. Kranjc M, "In situ monitoring of electric field distribution in mouse tumor during electroporation", Radiology, 274, pp.115~123 (2015)
  4. Neumann E, "Gene transfer into mouse lyoma cells by electroporation in high electric fields", EMBO J, 1, pp.841~845 (1982)
  5. Katscher U, "Determination of electric conductivity and local SAR via B1 mapping", IEEE Trans Med Imaging, 28, pp.1365~1374 (2009)
  6. Seo JK, "Error analysis of nonconstant admittivity for MR-based electric property imaging", IEEE Trans Med Imaging, 31, pp.430~437 (2012)
  7. Voigt T, "Quantitative conductivity and permittivity imaging of the human brain using electric properties tomography", Magn Reson Med, 66, pp.456~466 (2011)
  8. Kim HJ, "Simultaneous imaging of dual-frequency electrical conductivity using a combination of MREIT and MREPT", Magn Reson Med, 71, pp.200~208 (2014)
  9. Haemmerich D, "In vivo electrical conductivity of hepatic tumours", Physiol Meas, 24, pp.251~260 (2003)
  10. Oh TI, "Feasibility of magnetic resonance electrical impedance tomography(MREIT)conductivity imaging to evaluate brain abscess lesion : in vivo canine model", J Magn Reson Imaging, 38, pp.189~197 (2013)
  11. Lee SK, "Tissue electrical property mapping from zero echo-time magnetic resonance imaging", IEEE Trans Med Imaging, 34, pp.541~550 (2015)
  12. Seo JK, "Electrical tissue property imaging at low frequency using MREIT", IEEE Trans Biomed Eng, 61, pp.1390~1399 (2014)
  13. Tuch DS, "Conductivity tensor mapping of the human brain using diffusion tensor MRI", Proc Natl Acad Sci U S A, 98, pp.11697~11701 (2001)
  14. Kwon OI, "Anisotropic conductivity tensor imaging in MREIT using directional diffusion rate of water molecules", Phys Med Biol, 59, pp.2955~2974 (2014)
  15. Kwon OI, "Current density imaging during transcranial direct current stimulation using DT-MRI and MREIT : algorithm development and numerical simulations", IEEE Trans Biomed Eng, 63, pp.168~175 (2016)
  16. Sajib SZ, "Experimental evaluation of electrical conductivity imaging of anisotropic brain tissues using a combination of diffusion tensor imaging and magnetic resonance electrical impedance tomography", AIP Adv, 6, pp.065109~ (2016)
  17. Jeong WC, "Anisotropic conductivity tensor imaging of in vivo canine brain using DT-MREIT", IEEE Trans Med Imaging, 36, pp.124~131 (2017)
  18. Jeong WC, "Focused current density imaging using internal electrode in magnetic resonance electrical impedance tomography(MREIT)", IEEE Trans Biomed Eng, 61, pp.1938~1946 (2014)
  19. 이재웅, "Emerging Neural Stimulation Technologies for Bladder Dysfunctions", International Neurourology Journal, 19(1), pp.3~11 (2015), 대한배뇨장애요실금학회
  20. Wei XF, "Current density distributions, field distributions and impedance analysis of segmented deep brain stimulation electrodes", J Neural Eng, 2, pp.139~147 (2005)
  21. Lopez-Quintero SV, "DBS-relevant electric fields increase hydraulic conductivity of in vitro endothelial monolayers", J Neural Eng, 7, pp.16005~ (2010)
  22. Kochunov P, "Fractional anisotropy of cerebral white matter and thickness of cortical gray matter across the lifespan", Neuroimage, 58, pp.41~49 (2011)
  23. Sekino M, "Low-frequency conductivity tensor of rat brain tissues inferred from diffusion MRI", Bioelectromagnetics, 30, pp.489~499 (2009)
  24. Miranda PC, "The electric field in the cortex during transcranial current stimulation", Neuroimage, 70, pp.48~58 (2013)

관련 논문AI추천