본문 바로가기
KERD
논문KCI 등재

A Novel Mobile Acoustic Uroflowmetry: Comparison With Contemporary Uroflowmetry

1

조회

0

다운로드

3

인용

0

참고문헌

키워드

초록

Purpose: This study aimed to evaluate the accuracy and reliability of a new smartphone-based acoustic uroflowmetry compared to conventional uroflowmetry. Methods: This was a prospective validation study enrolling 128 subjects from September 2017 to April 2018 comparing a novel acoustic uroflowmetry to conventional uroflowmetry in an outpatient urologic clinic at Seoul National University Bundang Hospital. Visual comparison of flow patterns and uroflow parameters such as maximum flow rate (Qmax), average flow rate (Qavg), and voided volume were compared between the 2 techniques. Reliability and accuracy of the uroflowmetry results were compared using Pearson correlation coefficient (PCC) and Student t-test, respectively. Results: One hundred twelve participants were included in the study. Of these, 77 had baseline urologic comorbidities while 35 were normal participants. Flow patterns between the 2 uroflowmetry techniques demonstrated strong visual correlation. When compared to conventional uroflowmetry, all 3 parameters of voiding in male participants showed a very robust correlation with PCC of 0.88, 0.91, and 0.95 for Qmax, Qavg, and voided volume, respectively. Among female participants, we observed a PCC of 0.78, 0.93, and 0.96 for Qmax, Qavg, and voided volume, respectively. The Qmax showed a statistically significant difference in both sexes between the 2 methods, although the absolute value was small. Conclusions: Uroflowmetry using acoustic analysis demonstrates comparable findings to conventional uroflowmetry. This provides an opportunity to perform uroflowmetry in the clinic or at home in a reliable, inexpensive manner. Future large-scale prospective studies are required to further validate our results.

Abstract

Purpose: This study aimed to evaluate the accuracy and reliability of a new smartphone-based acoustic uroflowmetry compared to conventional uroflowmetry. Methods: This was a prospective validation study enrolling 128 subjects from September 2017 to April 2018 comparing a novel acoustic uroflowmetry to conventional uroflowmetry in an outpatient urologic clinic at Seoul National University Bundang Hospital. Visual comparison of flow patterns and uroflow parameters such as maximum flow rate (Qmax), average flow rate (Qavg), and voided volume were compared between the 2 techniques. Reliability and accuracy of the uroflowmetry results were compared using Pearson correlation coefficient (PCC) and Student t-test, respectively. Results: One hundred twelve participants were included in the study. Of these, 77 had baseline urologic comorbidities while 35 were normal participants. Flow patterns between the 2 uroflowmetry techniques demonstrated strong visual correlation. When compared to conventional uroflowmetry, all 3 parameters of voiding in male participants showed a very robust correlation with PCC of 0.88, 0.91, and 0.95 for Qmax, Qavg, and voided volume, respectively. Among female participants, we observed a PCC of 0.78, 0.93, and 0.96 for Qmax, Qavg, and voided volume, respectively. The Qmax showed a statistically significant difference in both sexes between the 2 methods, although the absolute value was small. Conclusions: Uroflowmetry using acoustic analysis demonstrates comparable findings to conventional uroflowmetry. This provides an opportunity to perform uroflowmetry in the clinic or at home in a reliable, inexpensive manner. Future large-scale prospective studies are required to further validate our results.

참고문헌 (12)

  1. Alothmany N, "Critical review of uroflowmetry methods", J Med Biol Eng, 38, pp.685~696 (2018)
  2. Abrams Paul, "Incontinence", pp.604~ (2017), International Continence Society
  3. Hitt D, "Urinary flow measurements via acoustic signatures with application to telemedicine", 39th AIAA Fluid Dynamics Conference. Fluid Dynamics and Co-located Conferences (2009), American Institute of Aeronautics and Astronautics
  4. Zvarova K, "Recording urinary flow and lower urinary tract symptoms using sonouroflowmetry", Can J Urol, 18, pp.5689~5694 (2011)
  5. Wiens K, "Novel optical uroflowmeter using image processing techniques", Measurement, 47, pp.314~320 (2014)
  6. Shokoueinejad M, "Video voiding device for diagnosing lower urinary tract dysfunction in men", J Med Biol Eng, 37, pp.474~483 (2017)
  7. Abrams Paul, "Incontinence" (2017), International Continence Society
  8. Krhut J, "Comparison between uroflowmetry and sonouroflowmetry in recording of urinary flow in healthy men", Int J Urol, 22, pp.761~765 (2015)
  9. Gartner M, "Evaluation of voiding parameters in healthy women using sound analysis", Low Urin Tract Symptoms, 10, pp.12~16 (2018)
  10. Song M, "Comparison of soundbased urinary flow prediction methods and validation with a large clinical sample", 25th International Congress on Sound and Vibration 2018 (ICSV 25) (2018)
  11. De La Rosette JJ, "Improved reliability of uroflowmetry investigations : results of a portable home-based uroflowmetry study", Br J Urol, 78, pp.385~390 (1996)
  12. "International Continence Society", 2020