Feasibility of watch-based blood pressure monitoring device in daily blood pressure monitoring

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Background: Cuffless blood pressure (BP) measurement devices integrated into smartwatches have gained prominence, yet limited studies provide the feasibility and preciseness of daily BP monitoring. Here, we evaluated the trackability of daily BP variance and the precision of the calibration process. Methods: We collected the data from 896 participants, reporting 35,592 BP values, and body composition analysis data measured by the Samsung Galaxy Watch 6 device. Participants were instructed to measure BP daily, in the morning (5 AM–9 AM) and evening (6 PM–10 PM) for 2 weeks, with initial calibration and re-calibration after the first week. Body composition data, obtained using the Galaxy Watch’s bioelectrical impedance analysis sensor, was measured voluntarily during the campaign without specific time constraints. Results: With BP readings collected using smartwatches, morning and evening BP values showed a significant difference, higher in the evening by 1.42 ± 5.25 mmHg (P < 0.05). Basal metabolic rate, skeletal muscle mass, total body water, morning systolic BP, morning pulse pressure, and morning heart rate were significantly associated with higher difference in morning-evening BP. The calibration stability was assessed by the difference in average BP before and after calibration, showing a substantial pre-post calibration BP difference by 4.64 ± 4.73 mmHg of systolic BP and 3.66 ± 3.62 mmHg of diastolic BP. Conclusions: In conclusion, watch-based devices may not detect clinical-level BP variability, and substantial extent of pre-post calibration error has to be solved for their utility in regular real-life BP monitoring.

Abstract

Background: Cuffless blood pressure (BP) measurement devices integrated into smartwatches have gained prominence, yet limited studies provide the feasibility and preciseness of daily BP monitoring. Here, we evaluated the trackability of daily BP variance and the precision of the calibration process. Methods: We collected the data from 896 participants, reporting 35,592 BP values, and body composition analysis data measured by the Samsung Galaxy Watch 6 device. Participants were instructed to measure BP daily, in the morning (5 AM–9 AM) and evening (6 PM–10 PM) for 2 weeks, with initial calibration and re-calibration after the first week. Body composition data, obtained using the Galaxy Watch’s bioelectrical impedance analysis sensor, was measured voluntarily during the campaign without specific time constraints. Results: With BP readings collected using smartwatches, morning and evening BP values showed a significant difference, higher in the evening by 1.42 ± 5.25 mmHg (P < 0.05). Basal metabolic rate, skeletal muscle mass, total body water, morning systolic BP, morning pulse pressure, and morning heart rate were significantly associated with higher difference in morning-evening BP. The calibration stability was assessed by the difference in average BP before and after calibration, showing a substantial pre-post calibration BP difference by 4.64 ± 4.73 mmHg of systolic BP and 3.66 ± 3.62 mmHg of diastolic BP. Conclusions: In conclusion, watch-based devices may not detect clinical-level BP variability, and substantial extent of pre-post calibration error has to be solved for their utility in regular real-life BP monitoring.

관련 논문AI추천

Feasibility, credence, and usefulness of out-of-office cuffless blood pressure monitoring using smartwatch: a population survey서종모, 이해영, 임상현, Jang Yongjun대한고혈압학회 · Clinical Hypertension2023 · 제29권 Smartphone / smartwatch-based cuffless blood pressure measurement : a position paper from the Korean Society of Hypertension김광일, 김대희, 김주한, 김현창, 박성하, 서종모, 성기철, 손일석, 신진호, 유승기, 이해영, 임상현, 정욱진, 조은주, 편욱범, Lee Dong-Ju대한고혈압학회 · Clinical Hypertension2021 · 제27권 제2호Validation of the iHealth-BP7 and Withings-BP800 blood pressure monitor for self-measurement according to the European Society Hypertension International Protocol revision 2010강성기, 안현성, 이정민한국체육측정평가학회 · 한국체육측정평가학회지2016 · 제18권 제3호When and how to use ambulatory blood pressure monitoring and home blood pressure monitoring for managing hypertensionLee Eun Mi대한고혈압학회 · Clinical Hypertension2024 · 제30권 Home blood pressure monitoring: a position statement from the Korean Society of Hypertension Home Blood Pressure Forum김광일, 김주한, 김철호, 박성하, 박재형, 신진호, 이은미, 이해영, 임상현, Kim Jang Young대한고혈압학회 · Clinical Hypertension2022 · 제28권 History and evolution of blood pressure measurementChae In-Ho, Kang Si-Hyuck, Kim Hwang-Soo, Noh Su A, Yoon Chang-Hwan, Youn Tae-Jin대한고혈압학회 · Clinical Hypertension2024 · 제30권

이 간행물의 다른 논문 (41건)