본문 바로가기
KERD
논문KCI 등재

Effect of Number of Measurement Points on Accuracy of Muscle T2 Calculations

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long (“phantom”) and short T2 (“polyvinyl alcohol gel”). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ± standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2- weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and monoexponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodnessof- fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodnessof- fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodnessof- fit when muscle T2 was considered mono-exponential.

Abstract

Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long (“phantom”) and short T2 (“polyvinyl alcohol gel”). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ± standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2- weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and monoexponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodnessof- fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodnessof- fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodnessof- fit when muscle T2 was considered mono-exponential.

참고문헌 (25)

  1. Fleckenstein JL, "Acute effects of exercise on MR imaging of skeletal muscle in normal volunteers", AJR Am J Roentgenol, 151, pp.231~237 (1988)
  2. Fleckenstein JL, "Muscle proton T2 relaxation times and work during repetitive maximal voluntary exercise", J Appl Physiol (1985), 74, pp.2855~2859 (1993)
  3. Saab G, "Effects of exercise on muscle transverse relaxation determined by MR imaging and in vivo relaxometry", J Appl Physiol (1985), 88, pp.226~233 (2000)
  4. Morvan D, "Simultaneous measurements of diffusion and transverse relaxation in exercising skeletal muscle", Magn Reson Imaging, 13, pp.943~948 (1995)
  5. Price TB, "Changes in magnetic resonance transverse relaxation times of two muscles following standardized exercise", Med Sci Sports Exerc, 27, pp.1421~1429 (1995)
  6. Price TB, "Effect of muscle glycogen content on exercise-induced changes in muscle T2 times", J Appl Physiol (1985), 84, pp.1178~1184 (1998)
  7. Ababneh ZQ, "On the correlation between T(2) and tissue diffusion coefficients in exercised muscle: quantitative measurements at 3T within the tibialis anterior", MAGMA, 21, pp.273~278 (2008)
  8. Nygren AT, "Water exchange induced by unilateral exercise in active and inactive skeletal muscles", J Appl Physiol (1985), 93, pp.1716~1722 (2002)
  9. Nygren AT., "Shortened T2 after exercise in ischemic skeletal muscle", J Magn Reson Imaging, 23, pp.177~182 (2006)
  10. Ploutz-Snyder LL, "Resistance exercise-induced fluid shifts: change in active muscle size and plasma volume", Am J Physiol, 269, pp.R536~R543 (1995)
  11. Ploutz-Snyder LL, "Different effects of exercise and edema on T2 relaxation in skeletal muscle", Magn Reson Med, 37, pp.676~682 (1997)
  12. Cannon DT, "Muscle metabolism and activation heterogeneity by combined 31P chemical shift and T2 imaging, and pulmonary O2 uptake during incremental knee-extensor exercise", J Appl Physiol (1985), 115, pp.839~849 (2013)
  13. Akima H, "Coactivation pattern in human quadriceps during isokinetic kneeextension by muscle functional MRI", Eur J Appl Physiol, 91, pp.7~14 (2004)
  14. Akima H, "Recruitment of the thigh muscles during sprint cycling by muscle functional magnetic resonance imaging", Int J Sports Med, 26, pp.245~252 (2005)
  15. Kinugasa R, "Quantitative assessment of skeletal muscle activation using muscle functional MRI", Magn Reson Imaging, 24, pp.639~644 (2006)
  16. Kubota J, "Relationship between the MRI and EMG measurements", Int J Sports Med, 30, pp.533~537 (2009)
  17. Tawara N, "Functional T(2)mapping of the trunkal muscle", Magn Reson Med Sci, 8, pp.81~83 (2009)
  18. Spiess AN, "An evaluation of R2 as an inadequate measure for nonlinear models in pharmacological and biochemical research: a Monte Carlo approach", BMC Pharmacol, 10, pp.6~ (2010)
  19. Gambarota G, "Osmotic effects on the T2 relaxation decay of in vivo muscle", Magn Reson Med, 46, pp.592~599 (2001)
  20. Tawara N, "Effects of MR image noise on estimation of short T2 values from T2-weighted image series", Magn Reson Med Sci, 6, pp.187~197 (2007)
  21. Press WH, "Numerical recipes in C (2nd ed.): the art of scientific computing", pp.629~661 (1996), Cambridge University Press New York
  22. Kjaer L, "Evaluation of relaxation time measurements by magnetic resonance imaging. A phantom study", Acta Radiol, 28, pp.345~351 (1987)
  23. Saab G, "Multicomponent T2relaxation of in vivo skeletal muscle", Magn Reson Med, 42, pp.150~157 (1999)
  24. Hazlewood CF, "Evidence for the existence of a minimum of two phases of ordered water in skeletal muscle", Nature, 222, pp.747~750 (1969)
  25. Hazlewood CF, "Nuclear magnetic resonance transverse relaxation times of water protons in skeletal muscle", Biophys J, 14, pp.583~606 (1974)

관련 논문AI추천

이 간행물의 다른 논문 (8건)