본문 바로가기
KERD
논문KCI 등재

Feasibility of In vivo Proton Magnetic Resonance Spectroscopy for Lung Cancer

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류방사선과학

초록

Purpose : To investigate the feasibility of in vivo proton magnetic resonance spectroscopy (MRS) for evaluation of lung cancer. Materials and Methods: This prospective study was approved by the institutional review board of our hospital and informed consent was obtained in all patients. Ten patients (7 men, 3 women; mean age, 64.4) with pathologicallyproven lung cancer (mean, 56.8 mm; range, 44-77 mm) were enrolled to 1.5 T MRS using a single-voxel respiration-triggered point-resolved spectroscopic sequence. Technical success rate and the reason of technical failure, if any, were investigated. Results: Out of 10 lung cancers, analyzable MRS spectra were obtained in 8 tumors (technical success rate, 80%). Two MRS datasets were not able to be analyzed due to serious baseline distortion. Choline and lipid signals were detected as major metabolites in analyzable MRS spectra. Conclusion: In vivo proton MRS method using a single-voxel respiration-triggered point-resolved spectroscopic sequence is feasible in obtaining the MR spectra of lung cancer because these spectra were analyzable and high success rate was shown in our study although there was the limitation of small patient group.

Abstract

Purpose : To investigate the feasibility of in vivo proton magnetic resonance spectroscopy (MRS) for evaluation of lung cancer. Materials and Methods: This prospective study was approved by the institutional review board of our hospital and informed consent was obtained in all patients. Ten patients (7 men, 3 women; mean age, 64.4) with pathologicallyproven lung cancer (mean, 56.8 mm; range, 44-77 mm) were enrolled to 1.5 T MRS using a single-voxel respiration-triggered point-resolved spectroscopic sequence. Technical success rate and the reason of technical failure, if any, were investigated. Results: Out of 10 lung cancers, analyzable MRS spectra were obtained in 8 tumors (technical success rate, 80%). Two MRS datasets were not able to be analyzed due to serious baseline distortion. Choline and lipid signals were detected as major metabolites in analyzable MRS spectra. Conclusion: In vivo proton MRS method using a single-voxel respiration-triggered point-resolved spectroscopic sequence is feasible in obtaining the MR spectra of lung cancer because these spectra were analyzable and high success rate was shown in our study although there was the limitation of small patient group.

참고문헌 (24)

  1. Brescia FJ, "Lung cancer--a philosophical, ethical, and personal perspective", Crit Rev Oncol Hematol, 40, pp.139~148 (2001)
  2. Mulshine JL, "Clinical practice. Lung cancer screening", The New England Journal of Medicine, 352, pp.2714~2720 (2005)
  3. Golder W, "Magnetic resonance spectroscopy in clinical oncology", Onkologie, 27, pp.304~309 (2004)
  4. Howe FA, "Metabolic profiles of human brain tumors using quantitative in vivo 1H magnetic resonance spectroscopy", Magn Reson Med, 49, pp.223~232 (2003)
  5. Scheidler J, "Prostate cancer: localization with three-dimensional proton MR spectroscopic imaging-clinicopathologic study", Radiology, 213, pp.473~480 (1999)
  6. Yeung DKW, "Human breast lesions: characterization with contrast-enhanced in vivo proton MR spectroscopyóInitial results", Radiology, 220, pp.40~46 (2001)
  7. Allen JR, "In vivo proton (H1) magnetic resonance spectroscopy for cervical carcinoma", Am J Clin Oncol, 24, pp.522~529 (2001)
  8. Hanaoka H, "In vitro characterization of lung cancers by the use of 1H nuclear magnetic resonance spectroscopy of tissue extracts and discriminant factor analysis", Magn Reson Med, 29, pp.436~440 (1993)
  9. Yokota H, "Lactate, choline, and creatine levels measured by vitro 1H-MRS as prognostic parameters in patients with non-small-cell lung cancer", J Magn Reson Imaging, 25, pp.992~999 (2007)
  10. Duarte IF, "Can nuclear magnetic resonance (NMR) spectroscopy reveal different metabolic signatures for lung tumours?", Virchows Arch, 457, pp.715~725 (2010)
  11. Rocha CM, "Metabolic profiling of human lung cancer tissue by 1H high resolution magic angle spinning (HRMAS) NMR spectroscopy", J Proteome Res, 9, pp.319~332 (2010)
  12. Christiansen P, "In vivo quantification of brain metabolites by 1H-MRS using water as an internal standard", Magn Reson Imaging, 11, pp.107~118 (1993)
  13. Stanwell P, "In vivo proton MR spectroscopy of the breast", Radiographics, 27(Suppl 1), pp.253~266 (2007)
  14. Qayyum A, "MR spectroscopy of the liver: principles and clinical applications", Radiographics, 29, pp.1653~1664 (2009)
  15. Opstad KS, "Correlations between in vivo (1)H MRS and ex vivo (1)H HRMAS metabolite measurements in adult human gliomas", J Magn Reson Imaging, 31, pp.289~297 (2010)
  16. Seppenwoolde Y, "Precise and realtime measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy", Int J Radiat Oncol Biol Phys, 53, pp.822~834 (2002)
  17. Guo J, "In vitro proton magnetic resonance spectroscopic lactate and choline measurements, 18FFDG uptake, and prognosis in patients with lung adenocarcinoma", J Nucl Med, 45, pp.1334~1339 (2004)
  18. Smith JK, "Effects of contrast material on single-volume proton MR spectroscopy", AJNR Am J Neuroradiol, 21, pp.1084~1089 (2000)
  19. Dydak U, "MR spectroscopy and spectroscopic imaging: comparing 3.0 T versus 1.5 T", Neuroimaging Clin N Am, 16, pp.269~283 (2006)
  20. Gabr RE, "On restoring motion-induced signal loss in single-voxel magnetic resonance spectra", Magn Reson Med, 56, pp.754~760 (2006)
  21. Weiss E, "Tumor and normal tissue motion in the thorax during respiration: analysis of volumetric and positional variations using 4D CT", Int J Radiat Oncol Biol Phys, 67, pp.296~307 (2007)
  22. Chen W, "Study on metabonomic characteristics of human lung cancer using high resolution magic-angle spinning 1H NMR spectroscopy and multivariate data analysis", Magn Reson Med, 66, pp.1531~1540 (2011)
  23. Kuo YT, "In vivo proton magnetic resonance spectroscopy of large focal hepatic lesions and metabolite change of hepatocellular carcinoma before and after transcatheter arterial chemoembolization using 3.0-T MR scanner", J Magn Reson Imaging, 19, pp.598~604 (2004)
  24. Gold GE, "Short echo time MR spectroscopic imaging of the lung parenchyma", J Magn Reson Imaging, 15, pp.679~684 (2002)

관련 논문AI추천

T2-relaxation Time Measurement of ex vivo 1H MR Metabolite Peaks for Evaluation of Human Stomach Cancer양영일, Chi-Woong Mun, Chung Ki Eun, Hee-Kyung Chang, Ki-Sueng Choi, Oon-Jae Shin, Xiaoping Hu대한의용생체공학회 · 의공학회지2006 · 제27권 제2호Differential Diagnosis of Brain Diseases Using In Vivo Proton Magnetic Resonance Spectroscopy at 3Tesla : A Preliminary Study강형근, 김태훈, 정광우, Hyeong-Jung Kim, Thirunavukkarasu Sundaram, Yu-Lan Shen한국자기공명학회 · Journal of the Korean Magnetic Resonance Society2009 · 제13권 제2호자기공명분광 검사 시 프로토콜 이해: 문헌연구 중심으로구은회, 류영환, 백민규(사)한국방사선산업학회 · 방사선산업학회지2023 · 제17권 제4호MR Spectroscopy and Diffusion Weighted Imaging Findings of Primary Non-Hodgkin Lymphoma of the Breast: Two Case Reports남상유, 유은영, 최혜영대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2014 · 제18권 제2호낭성 종양의 체액에 대한 생체내, 생체외 3T 양성자 자기공명분광법과 양성자 핵자기공명기법의 비교: Preliminary Study김종열, 이희중, 장용민대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2008 · 제12권 제2호Utility of Magnetic Resonance Imaging in the Diagnosis of Lung Adenocarcinoma with Extensive Necrosis: a Case ReportByung-Joon Park, Hye Won Choi, Jae Yeol Kim, Mi Kyung Kim, Min Jae Cha, Sang Lim Choi대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2018 · 제22권 제4호

이 간행물의 다른 논문 (9건)