Purpose: To analyze the feasibility of three-dimensional (3D) diffusion-weighted (DW) PSIF (reversed FISP [fast imaging with steady-state free precession]) sequence in order to evaluate peripheral nerves in the elbow. Materials and Methods: Ten normal, asymptomatic volunteers were enrolled (6 men, 4 women, mean age 27.9 years). The following sequences of magnetic resonance images (MRI) of the elbow were obtained using a 3.0-T machine: 3D DW PSIF, 3D T2 SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) with SPAIR (spectral adiabatic inversion recovery) and 2D T2 TSE (turbo spin echo) with modified Dixon (m-Dixon) sequence. Two observers used a 5-point grading system to analyze the image quality of the ulnar, median, and radial nerves. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each nerve were measured. We compared 3D DW PSIF images with other sequences using the Wilcoxon-signed rank test and Friedman test. Inter-observer agreement was measured using intraclass correlation coefficient (ICC) analysis. Results: The mean 5-point scores of radial, median, and ulnar nerves in 3D DW PSIF (3.9/4.2/4.5, respectively) were higher than those in 3D T2 SPACE SPAIR (1.9/2.8/2.8) and 2D T2 TSE m-Dixon (1.7/2.8/2.9) sequences (P < 0.05). The mean SNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR, but there was no difference between 3D DW PSIF and 2D T2 TSE m-Dixon in all of the three nerves. The mean CNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR and 2D T2 TSE m-Dixon in the median and ulnar nerves, but no difference among the three sequences in the radial nerve. Conclusion: The three-dimensional DW PSIF sequence may be feasible to evaluate the peripheral nerves around the elbow in MR imaging. However, further optimization of the image quality (SNR, CNR) is required.

Abstract

Purpose: To analyze the feasibility of three-dimensional (3D) diffusion-weighted (DW) PSIF (reversed FISP [fast imaging with steady-state free precession]) sequence in order to evaluate peripheral nerves in the elbow. Materials and Methods: Ten normal, asymptomatic volunteers were enrolled (6 men, 4 women, mean age 27.9 years). The following sequences of magnetic resonance images (MRI) of the elbow were obtained using a 3.0-T machine: 3D DW PSIF, 3D T2 SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) with SPAIR (spectral adiabatic inversion recovery) and 2D T2 TSE (turbo spin echo) with modified Dixon (m-Dixon) sequence. Two observers used a 5-point grading system to analyze the image quality of the ulnar, median, and radial nerves. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each nerve were measured. We compared 3D DW PSIF images with other sequences using the Wilcoxon-signed rank test and Friedman test. Inter-observer agreement was measured using intraclass correlation coefficient (ICC) analysis. Results: The mean 5-point scores of radial, median, and ulnar nerves in 3D DW PSIF (3.9/4.2/4.5, respectively) were higher than those in 3D T2 SPACE SPAIR (1.9/2.8/2.8) and 2D T2 TSE m-Dixon (1.7/2.8/2.9) sequences (P < 0.05). The mean SNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR, but there was no difference between 3D DW PSIF and 2D T2 TSE m-Dixon in all of the three nerves. The mean CNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR and 2D T2 TSE m-Dixon in the median and ulnar nerves, but no difference among the three sequences in the radial nerve. Conclusion: The three-dimensional DW PSIF sequence may be feasible to evaluate the peripheral nerves around the elbow in MR imaging. However, further optimization of the image quality (SNR, CNR) is required.

참고문헌 (10)

  1. Chhabra A, "MR neurography:past, present, and future", AJR Am J Roentgenol, 197, pp.583~591 (2011)
  2. Thawait SK, "High-resolution MR neurography of diffuse peripheral nerve lesions", AJNR Am J Neuroradiol, 32, pp.1365~1372 (2011)
  3. Chhabra A, "Magnetic resonance neurography: technical considerations", Neuroimaging Clin N Am, 24, pp.67~78 (2014)
  4. Chhabra A, "The application of three-dimensional diffusion-weighted PSIF technique in peripheral nerve imaging of the distal extremities", J Magn Reson Imaging, 34, pp.962~967 (2011)
  5. Chhabra A, "3T MR neurography using three-dimensional diffusionweighted PSIF: technical issues and advantages", Skeletal Radiol, 40, pp.1355~1360 (2011)
  6. Zhang Z, "3-T imaging of the cranial nerves using three-dimensional reversed FISP with diffusion-weighted MR sequence", J Magn Reson Imaging, 27, pp.454~458 (2008)
  7. Enochs WS, "MR imaging of the peripheral nervous system", J Magn Reson Imaging, 4, pp.251~257 (1994)
  8. Filler AG, "Application of magnetic resonance neurography in the evaluation of patients with peripheral nerve pathology", J Neurosurg, 85, pp.299~309 (1996)
  9. Chhabra A, "MR neurography:advances", Radiol Res Pract, 2013, pp.809568~ (2013)
  10. Umutlu L, "New look at renal vasculature: 7 tesla nonenhanced T1-weighted FLASH imaging", J Magn Reson Imaging, 36, pp.714~721 (2012)

관련 논문AI추천

The Relationship Between Magnetic Resonance Imaging and Electrodiagnostic Studies in Patients with Ulnar Neuropathy at the Elbow고은재, 이민희, Kang Min Soo, Kim Dae Yul, Lee Jung Eun, Seo Yu Jin대한근전도전기진단의학회 · 대한근전도 전기진단의학회지2022 · 제24권 제2호Comparison of 2D Thin Section Dixon, 3D Isotropic SPACE, and 2D T2-Weighted Sequences in Ankle MRI전지영, Sheen-Woo Lee, So Hyun Park, Tae Ran Ahn, Yu Mi Jeong대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2022 · 제26권 제4호Enhancement Pattern of the Normal Facial Nerve on Three - Dimensional (3D) - Fluid Attenuated Inversion Recovery (FLAIR) Sequence at 3.0 T MR Units김종림, 박순찬, 박지원, 백정환, 안중호, 이정현, 이하영, 임현경, 최충곤, 현동호대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2012 · 제16권 제1호Diagnostic Cutoff Value for Ultrasonography in the Ulnar Neuropathy at the Elbow김주희, 박혜정, 원선재, 이원일, 홍현미대한재활의학회 · Annals of Rehabilitation Medicine2015 · 제39권 제2호Diagnosis of Rotator Cuff Tears with Non-Arthrographic MR Imaging: 3D Fat-Suppressed Isotropic Intermediate-Weighted Turbo Spin-Echo Sequence versus Conventional 2D Sequences at 3T김양수, 정준용, 지원희, Chang Woo Chun, So-Yeon Lee, Won Sun Hong대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2018 · 제22권 제4호The prognostic value of median nerve thickness in diagnosing carpal tunnel syndrome using magnetic resonance imaging: a pilot studyHyung Rae Cho, Jun Sung Yoo, Sooho Lee, Young Uk Kim대한통증학회 · The Korean Journal of Pain2020 · 제33권 제1호

이 간행물의 다른 논문 (9건)