Computer-Aided Detection with Automated Breast Ultrasonography for Suspicious Lesions Detected on Breast MRI
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Purpose: The aim of this study was to evaluate the diagnostic performance of a computer-aided detection (CAD) system used with automated breast ultrasonography (ABUS) for suspicious lesions detected on breast MRI, and CAD-false lesions. Materials and Methods: We included a total of 40 patients diagnosed with breast cancer who underwent ABUS (ACUSON S2000) to evaluate multiple suspicious lesions found on MRI. We used CAD (QVCADTM) in all the ABUS examinations. We evaluated the diagnostic accuracy of CAD and analyzed the characteristics of CAD-detected lesions and the factors underlying false-positive and false-negative cases. We also analyzed false-positive lesions with CAD on ABUS. Results: Of a total of 122 suspicious lesions detected on MRI in 40 patients, we excluded 51 daughter nodules near the main breast cancer within the same quadrant and included 71 lesions. We also analyzed 23 false-positive lesions using CAD with ABUS. The sensitivity, specificity, positive predictive value, and negative predictive value of CAD (for 94 lesions) with ABUS were 75.5%, 44.4%, 59.7%, and 62.5%, respectively. CAD facilitated the detection of 81.4% (35/43) of the invasive ductal cancer and 84.9% (28/33) of the invasive ductal cancer that showed a mass (excluding non-mass). CAD also revealed 90.3% (28/31) of the invasive ductal cancers measuring larger than 1 cm (excluding non-mass and those less than 1 cm). The mean sizes of the true-positive versus false-negative mass lesions were 2.08 ± 0.85 cm versus 1.6 ± 1.28 cm (P < 0.05). False-positive lesions included sclerosing adenosis and usual ductal hyperplasia. In a total of 23 false cases of CAD, the most common (18/23) cause was marginal or subareolar shadowing, followed by three simple cysts, a hematoma, and a skin wart. Conclusion: CAD with ABUS showed promising sensitivity for the detection of invasive ductal cancer showing masses larger than 1 cm on MRI.
Abstract
Purpose: The aim of this study was to evaluate the diagnostic performance of a computer-aided detection (CAD) system used with automated breast ultrasonography (ABUS) for suspicious lesions detected on breast MRI, and CAD-false lesions. Materials and Methods: We included a total of 40 patients diagnosed with breast cancer who underwent ABUS (ACUSON S2000) to evaluate multiple suspicious lesions found on MRI. We used CAD (QVCADTM) in all the ABUS examinations. We evaluated the diagnostic accuracy of CAD and analyzed the characteristics of CAD-detected lesions and the factors underlying false-positive and false-negative cases. We also analyzed false-positive lesions with CAD on ABUS. Results: Of a total of 122 suspicious lesions detected on MRI in 40 patients, we excluded 51 daughter nodules near the main breast cancer within the same quadrant and included 71 lesions. We also analyzed 23 false-positive lesions using CAD with ABUS. The sensitivity, specificity, positive predictive value, and negative predictive value of CAD (for 94 lesions) with ABUS were 75.5%, 44.4%, 59.7%, and 62.5%, respectively. CAD facilitated the detection of 81.4% (35/43) of the invasive ductal cancer and 84.9% (28/33) of the invasive ductal cancer that showed a mass (excluding non-mass). CAD also revealed 90.3% (28/31) of the invasive ductal cancers measuring larger than 1 cm (excluding non-mass and those less than 1 cm). The mean sizes of the true-positive versus false-negative mass lesions were 2.08 ± 0.85 cm versus 1.6 ± 1.28 cm (P < 0.05). False-positive lesions included sclerosing adenosis and usual ductal hyperplasia. In a total of 23 false cases of CAD, the most common (18/23) cause was marginal or subareolar shadowing, followed by three simple cysts, a hematoma, and a skin wart. Conclusion: CAD with ABUS showed promising sensitivity for the detection of invasive ductal cancer showing masses larger than 1 cm on MRI.
참고문헌 (14)
- An YY, "The image quality and lesion characterization of breast using automated whole-breast ultrasound: a comparison with handheld ultrasound", Eur J Radiol, 84, pp.1232~1235 (2015)
- Jeh SK, "Comparison of automated breast ultrasonography to handheld ultrasonography in detecting and diagnosing breast lesions", Acta Radiol, 57, pp.162~169 (2016)
- Wang ZL, "Comparison of automated breast volume scanning to hand-held ultrasound and mammography", Radiol Med, 117, pp.1287~1293 (2012)
- van Zelst JCM, "Improved cancer detection in automated breast ultrasound by radiologists using computer aided detection", Eur J Radiol, 89, pp.54~59 (2017)
- 신희정, "Current status of automated breast ultrasonography", ULTRASONOGRAPHY, 34(3), pp.165~172 (2015), 대한초음파의학회
- Kim Y, "Comparison and combination of two ultrasound modalities, handheld ultrasound and automated breast volume scanner, with and without knowledge of MRI", Iran J Radiol, 15, pp.e60176~ (2018)
- Wang HY, "Differentiation of benign and malignant breast lesions: a comparison between automatically generated breast volume scans and handheld ultrasound examinations", Eur J Radiol, 81, pp.3190~3200 (2012)
- Chang JM, "Radiologists'performance in the detection of benign and malignant masses with 3D automated breast ultrasound (ABUS)", Eur J Radiol, 78, pp.99~103 (2011)
- Van Zelst JC, "Multiplanar reconstructions of 3D automated breast ultrasound improve lesion differentiation by radiologists", Acad Radiol, 22, pp.1489~1496 (2015)
- 김정현, "Computer-aided detection system for masses in automated whole breast ultrasonography: development and evaluation of the effectiveness", ULTRASONOGRAPHY, 33(2), pp.105~115 (2014), 대한초음파의학회[DOI]
- Drukker K, "Automated method for improving system performance of computer-aided diagnosis in breast ultrasound", IEEE Trans Med Imaging, 28, pp.122~128 (2009)
- Berg WA, "Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer", Radiology, 233, pp.830~849 (2004)
- Wiratkapun C, "Indeterminate or suspicious breast lesions detected initially with MR imaging: value of MRI-directed breast ultrasound", Acad Radiol, 15, pp.618~625 (2008)
- Abe H, "MR-directed ("Second-Look") ultrasound examination for breast lesions detected initially on MRI: MR and sonographic findings", AJR Am J Roentgenol, 194, pp.370~377 (2010)