Reduced Scan Time in Multi-Echo Gradient Echo Imaging Using Two-Stage Neural Network
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: Multi-echo gradient echo (mGRE) images are used to acquire and analyze multiple echo signals. As the number of acquired echoes increases, more information on the voxel decay changes can be obtained, facilitating myelin water fraction (MWF) mapping. However, an increase in the acquired echoes leads to an increase in scan time. In this study, we developed a workflow to reduce the scan time using a two-stage neural network approach, which extrapolates additional echo images using mGRE data. Materials and Methods: In Stage 1, a pseudo-T1 map was estimated using a U-net network combined with a simple signal model to correct the bias between two mGRE acquired with different scan parameters. The pseudo-T1 map was used to generate an initial echo time (TE) image from the mGRE images. In Stage 2, subsequent TE images were predicted from the initial echo image generated using a trained prediction network. The results were quantitatively compared with those obtained using a fitting algorithm. The MWF mapping results were then compared. Results: The proposed model exhibited better root mean square error, structural similarity index measure, and peak signal-to-noise ratio, as well as a higher correlation with the MWF analysis compared to the fitting algorithm. Conclusion: These results demonstrate that the proposed network can effectively reduce the scan time for mGRE image acquisition.
Abstract
Purpose: Multi-echo gradient echo (mGRE) images are used to acquire and analyze multiple echo signals. As the number of acquired echoes increases, more information on the voxel decay changes can be obtained, facilitating myelin water fraction (MWF) mapping. However, an increase in the acquired echoes leads to an increase in scan time. In this study, we developed a workflow to reduce the scan time using a two-stage neural network approach, which extrapolates additional echo images using mGRE data. Materials and Methods: In Stage 1, a pseudo-T1 map was estimated using a U-net network combined with a simple signal model to correct the bias between two mGRE acquired with different scan parameters. The pseudo-T1 map was used to generate an initial echo time (TE) image from the mGRE images. In Stage 2, subsequent TE images were predicted from the initial echo image generated using a trained prediction network. The results were quantitatively compared with those obtained using a fitting algorithm. The MWF mapping results were then compared. Results: The proposed model exhibited better root mean square error, structural similarity index measure, and peak signal-to-noise ratio, as well as a higher correlation with the MWF analysis compared to the fitting algorithm. Conclusion: These results demonstrate that the proposed network can effectively reduce the scan time for mGRE image acquisition.
참고문헌 (23)
- Markl M, "Gradient echo imaging", J Magn Reson Imaging, 35, pp.1274~1289 (2012)
- Hargreaves BA, "Rapid gradient-echo imaging", J Magn Reson Imaging, 36, pp.1300~1313 (2012)
- Jung S, "Improved multi-echo gradient echo myelin water fraction mapping using complex-valued neural network analysis", Magn Reson Med, 88, pp.492~500 (2022)
- Hwang D, "In vivo multi-slice mapping of myelin water content using T2* decay", Neuroimage, 52, pp.198~204 (2010)
- Nam Y, "Improved estimation of myelin water fraction using complex model fitting", Neuroimage, 116, pp.214~221 (2015)
- Du YP, "Fast multislice mapping of the myelin water fraction using multicompartment analysis of T2*decay at 3T : a preliminary postmortem study", Magn Reson Med, 58, pp.865~870 (2007)
- Yin X, "k-TE generalized autocalibrating partially parallel acquisition(GRAPPA)for accelerated multiple gradient-recalled echo(MGRE)R2* mapping in the abdomen", Magn Reson Med, 61, pp.507~516 (2009)
- Drenthen GS, "Applicability and reproducibility of 2D multi-slice GRASE myelin water fraction with varying acquisition acceleration", Neuroimage, 195, pp.333~339 (2019)
- Chen HS, "Compressed sensing CPMG with group-sparse reconstruction for myelin water imaging", Magn Reson Med, 71, pp.1166~1171 (2014)
- Chen Q, "Whole brain myelin water mapping in one minute using tensor dictionary learning with low-rank plus sparse regularization", IEEE Trans Med Imaging, 40, pp.1253~1266 (2021)
- Lee JH, "Accelerated 3D myelin water imaging using joint spatio-temporal reconstruction", Med Phys, 49, pp.5929~5942 (2022)
- Wang Z, "Parallel non-Cartesian spatialtemporal dictionary learning neural networks(stDLNN)for accelerating 4D-MRI", Med Image Anal, 84, pp.102701~ (2023)
- Lee H, "Echo time-range effects on gradient-echo based myelin water fraction mapping at 3T", Magn Reson Med, 81, pp.2799~2807 (2019)
- Ronneberger O, "Medical image computing and computer-assisted intervention–MICCAI 2015", pp.234~241 (2015), Springer
- Sutskever I, "Sequence to sequence learning with neural networks", Advances in neural information processing systems. 28th Annual Conference on Neural Information Processing Systems, pp.3104~3112 (2015), Curran Associates, Inc.
- Shin W, "Fast high-resolution T1 mapping using inversion-recovery Look-Locker echo-planar imaging at steady state : optimization for accuracy and reliability", Magn Reson Med, 61, pp.899~906 (2009)
- Lu H, "Routine clinical brain MRI sequences for use at 3. 0 tesla", J Magn Reson Imaging, 22, pp.13~22 (2005)
- Chen L, "Measurements of T1 relaxation times at 3.0T: implications for clinical MRA", Proceedings of the International Society for Magnetic Resonance in Medicine, pp.1391~ (2001)
- Ethofer T, "Comparison of longitudinal metabolite relaxation times in different regions of the human brain at 1. 5 and 3 tesla", Magn Reson Med, 50, pp.1296~1301 (2003)
- Preibisch C, "T1 mapping using spoiled FLASH-EPI hybrid sequences and varying flip angles", Magn Reson Med, 62, pp.240~246 (2009)
- Dieringer MA, "Rapid parametric mapping of the longitudinal relaxation time T1 using two-dimensional variable flip angle magnetic resonance imaging at 1. 5tesla, 3 tesla, and 7 tesla", PLoS One, 9, pp.e91318~ (2014)
- Jung S, "Artificial neural network for multiecho gradient echo-based myelin water fraction estimation", Magn Reson Med, 85, pp.380~389 (2021)
- Griswold MA, "Generalized autocalibrating partially parallel acquisitions(GRAPPA)", Magn Reson Med, 47, pp.1202~1210 (2002)
