본문 바로가기
KERD
논문KCI 등재

Reliability and Validity of the Postural Balance Application Program Using the Movement Accelerometer Principles in Healthy Young Adults

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류물리치료학

초록

The purpose of this study was to determine the reliability and validity of the postural balance program which uses the movement accelerating field principles of posture balance training and evaluation equipment and smartphone movement accelerometer program (SMAP) in healthy young adults. A total of 34 people were appointed as the subject among the healthy young adults. By using Biodex stability system (BSS) and SMAP on the subject, the posture balance capability was evaluated. For the test-retest reliability, SMAP showed the intra-class correlation (ICC: .62∼.91) and standard error measurement (SEM: .01∼.08). BSS showed the moderate to high reliability of ICC (.88∼.93) and SEM (.02∼.20). In the reliability of inter-rater, ICC (.59∼.73) as to SMAP, showed the reliability of moderate in eyes open stability all (EOSA), eyes open stability anterior posterior (EOSAP), eyes open stability medial lateral (EOSML) and eyes open dinamic all (EODA), eyes open danamic anterior posterior (EODAP), and eyes open danamic medial lateral (EODML). However, ICC showed reliability which was as low as .59 less than in other movements. In addition, BSS showed the reliability of high as ICC (.70∼.75). It showed reliability which was as low as ICC (.59 less than) in other movements. In correlation to the balance by attitudes between SMAP and BSS, EOSML (r=.62), EODA (r=.75), EODML (r=.72), ECDAP (r=.64), and ECDML (r=.69) shown differ significantly (p<.05). However, the correlation noted in other movements did not differ significantly. Therefore, SMAP and BSS can be usefully used in the posture balance assessment of the static and dynamic condition with eyes opened and closed.

Abstract

The purpose of this study was to determine the reliability and validity of the postural balance program which uses the movement accelerating field principles of posture balance training and evaluation equipment and smartphone movement accelerometer program (SMAP) in healthy young adults. A total of 34 people were appointed as the subject among the healthy young adults. By using Biodex stability system (BSS) and SMAP on the subject, the posture balance capability was evaluated. For the test-retest reliability, SMAP showed the intra-class correlation (ICC: .62∼.91) and standard error measurement (SEM: .01∼.08). BSS showed the moderate to high reliability of ICC (.88∼.93) and SEM (.02∼.20). In the reliability of inter-rater, ICC (.59∼.73) as to SMAP, showed the reliability of moderate in eyes open stability all (EOSA), eyes open stability anterior posterior (EOSAP), eyes open stability medial lateral (EOSML) and eyes open dinamic all (EODA), eyes open danamic anterior posterior (EODAP), and eyes open danamic medial lateral (EODML). However, ICC showed reliability which was as low as .59 less than in other movements. In addition, BSS showed the reliability of high as ICC (.70∼.75). It showed reliability which was as low as ICC (.59 less than) in other movements. In correlation to the balance by attitudes between SMAP and BSS, EOSML (r=.62), EODA (r=.75), EODML (r=.72), ECDAP (r=.64), and ECDML (r=.69) shown differ significantly (p<.05). However, the correlation noted in other movements did not differ significantly. Therefore, SMAP and BSS can be usefully used in the posture balance assessment of the static and dynamic condition with eyes opened and closed.

참고문헌 (26)

  1. Arnold BL, "Examination of balance measures produced by the biodex stability system", J Athl Train, 33(4), pp.323~327 (1998)
  2. Baker CP, "Reliability of static standing balance in nondisabled children : Comparison of two methods of measurement", Pediatr Rehabil, 2(1), pp.15~20 (1998)
  3. Barnett A, "Community-based group exercise improves balance and reduces falls in at-risk older people: A randomised controlled trial", Age Ageing, 32(4), pp.407~414 (2003)
  4. Boucher P, "Postural stability in diabetic polyneuropathy", Diabetes Care, 18(5), pp.638~645 (1995)
  5. Cachupe WJC, "Reliability of Biodex balance system measures", Meas Phys Educ Exerc Sci, 5(2), pp.97~108 (2001)
  6. Domholdt E, "Rehabilitation Research: Principles and applications" (2005), Elsevier Saunders
  7. Gardner MM, "Exercise in preventing falls and fall related injuries in older people: A review of randomised controlled trials", Br J Sports Med, 34(1), pp.7~17 (2000)
  8. Goldie PA, "Force platform measures for evaluating postural control: Reliability and validity", Arch Phys Med Rehabil, 70(7), pp.510~517 (1989)
  9. Goldie PA, "Steadiness in one-legged stance: Development of a reliable force-platform testing procedure", Arch Phys Med Rehabil, 73(4), pp.348~354 (1992)
  10. Hamman RG, "Training effects during repeated therapy sessions of balance training using visual feedback", Arch Phys Med Rehabil, 73(8), pp.738~744 (1992)
  11. Hinman MR, "Factors affecting reliability of the Biodex balance system; A summary of four studies", J Sports Rehabil, 9, pp.240~252 (2000)
  12. Hocherman S, "Platform training and postural stability in hemiplegia", Arch Phys Med Rehabil, 65(10), pp.588~592 (1984)
  13. Jakicic JM, "The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure", Med Sci Sports Exerc, 31(5), pp.747~754 (1999)
  14. Ku PX, "The effect on human balance of standing with toe-extension", PLoS One, 7(7), pp.e41539~ (2012)
  15. Levine JA, "Validation of the Tracmor triaxial accelerometer system for walking", Med Sci Sports Exerc, 33(9), pp.1593~1597 (2001)
  16. Montoye HJ, "Estimation of energy expenditure by a portable accelerometer", Med Sci Sports Exerc, 15(5), pp.403~407 (1983)
  17. Najafi B, "Ambulatory system for human motion analysis using a kinematic sensor: Monitoring of daily physical activity in the elderly", IEEE Trans Biomed Eng, 50(6), pp.711~723 (2003)
  18. Nichols DS, "Changes in the mean center of balance during balance testing in young adults", Phys Ther, 75(8), pp.699~706 (1995)
  19. Nitz JC, "The efficacy of a specific balance- strategy training programme for preventing falls among older people: A pilot randomised controlled trial", Age Ageing, 33(1), pp.52~58 (2004)
  20. Pambianco G, "Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure", Med Sci Sports Exerc, 22(6), pp.858~862 (1990)
  21. Pereira HM, "Influence of knee position on the postural stability index registered by the Biodex Stability System", Gait Posture, 28(4), pp.668~672 (2008)
  22. Pincivero DM, "Reliability and precision of isokinetic strength and muscular endurance for quadriceps and hamstrings", Int J Sports Med, 18(2), pp.113~117 (1997)
  23. Schmitz RJ, "Intertester and intratester reliability of a dynamic balance protocol using the Biodex Stability System", J Sport Rehabil, 7, pp.95~101 (1998)
  24. Shumway-Cook A, "Assessing the influence of sensory interaction on balance. Suggestion from the field", Phys Ther, 66(10), pp.1548~1550 (1986)
  25. Testerman C, "Evaluation of ankle instability using the Biodex stability system", Foot Ankle Int, 20(5), pp.317~321 (1999)
  26. Welk GJ, "The utility of the Digi-walker step counter to assess daily physical activity patterns", Med Sci Sports Exerc, 32(9), pp.481~488 (2000)

관련 논문AI추천

이 간행물의 다른 논문 (7건)