맥진기 판독의 신뢰도 및 파형의 재현성 연구
Study on Reliability of Interpretation and Reproducibility of a Pulse Analyser
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Objectives : This study was performed to evaluate inter-rater and intra-rater reliability of interpretation and reproducibility of a pulse analyser (MAXMAC27-Plus). Methods : 38 of 40 volunteers completed the pulse analysis consecutively. Three Korean medical doctors who had at least 2 years of clinical experience interpreted the pulse waves for 3 aspects of size, depth and shape, then inter-rater reliability and crude agreement was obtained. Reinterpretation was done 2 weeks later and intra-rater reliability and crude agreement was obtained. Intra-rater reliability and crude agreement between 1st and 2nd measurement was calculated. Cohen's weighted kappa for size, Cohen's kappa for depth and shape were used as statistical analysis. Results : Inter-rater reliability of size, depth and shape among 3 raters was 0.598, 0.604, and 0.312, respectively, showing moderate to substantial agreement. Average intra-rater reliability between 1st and 2nd interpretation of size, depth and shape was 0.806, 0.705, and 0.638, respectively, showing substantial to almost perfect agreement. However, intra-rater reliability between consecutive measurements of size, depth and shape was 0.221, 0.121, and 0.194, respectively, which showed only poor to fair agreement. Conclusions : Intra-rater and inter-rater reliability of one pulse wave showed relatively high concordance. Training by a clinical expert may effect better concordance among raters. Test-retest reliability showed poor agreement. Improvement of measurement technique and device performance will be needed.
Abstract
Objectives : This study was performed to evaluate inter-rater and intra-rater reliability of interpretation and reproducibility of a pulse analyser (MAXMAC27-Plus). Methods : 38 of 40 volunteers completed the pulse analysis consecutively. Three Korean medical doctors who had at least 2 years of clinical experience interpreted the pulse waves for 3 aspects of size, depth and shape, then inter-rater reliability and crude agreement was obtained. Reinterpretation was done 2 weeks later and intra-rater reliability and crude agreement was obtained. Intra-rater reliability and crude agreement between 1st and 2nd measurement was calculated. Cohen's weighted kappa for size, Cohen's kappa for depth and shape were used as statistical analysis. Results : Inter-rater reliability of size, depth and shape among 3 raters was 0.598, 0.604, and 0.312, respectively, showing moderate to substantial agreement. Average intra-rater reliability between 1st and 2nd interpretation of size, depth and shape was 0.806, 0.705, and 0.638, respectively, showing substantial to almost perfect agreement. However, intra-rater reliability between consecutive measurements of size, depth and shape was 0.221, 0.121, and 0.194, respectively, which showed only poor to fair agreement. Conclusions : Intra-rater and inter-rater reliability of one pulse wave showed relatively high concordance. Training by a clinical expert may effect better concordance among raters. Test-retest reliability showed poor agreement. Improvement of measurement technique and device performance will be needed.
참고문헌 (21)
- 채우석, "한의학 개론", pp.310~ (1997), 대성문화사
- 하인영, "맥의 빠르기, 크기, 깊이에 관한 전통맥진과 기기측정 맥진의 비교 연구", Korean Journal of Acupuncture, 28(1), pp.23~37 (2011), 경락경혈학회
- King E, "The reliable measurement of radial pulse characteristics", Acupuncture Med, 20, pp.150~159 (2002)
- O'Brien KA, "Understanding the reliability if diagnostic variables in a Chinese medicine examination", J Altern Complement Med, 15(7), pp.727~734 (2009)
- O'Brien KA, "A review of the reliability of traditional east asian medicine diagnoses", J Altern Complement Med, 15(4), pp.353~366 (2009)
- 김은혜, "희수식 전자맥진기의 재조명", 대전대학교 한의학연구소 논문집, 18(2), pp.37~45 (2009)
- 박동일, "희수식 맥진기를 이용한 감모환자의 폐맥에 대한 고찰", 대한한의학회맥진학회지, 4, pp.120~140 (1999)
- 박동일, "희수식 맥진기를 이용한 소화기 환자의 비위간담맥의 맥증에 대한 고찰", 대한한의학회맥진학회지, 4, pp.88~119 (1999)
- 신병철, "맥진기를 이용한 중풍환자의 임상적 고찰", 대한동의병리학회지, 13(2), pp.123~127 (1999)
- 하예진, "펜타입 압저항 센서를 활용한 연령별 맥파 특성 및 맥파의 대사증후군에의 적용 가능성 평가", 대한한방내과학회지, 33(3), pp.257~271 (2012), 대한한방내과학회
- 장원석, "두통 및 어지럼증 입원환자의 맥진기를 이용한 통계적 고찰", 대한한방내과학회 추계학술대회지, pp.196~207 (2011)
- 강세영, "맥진기 결과에 대한 판독자간의 판독 일치율 비교 연구", Korean Journal of Acupuncture, 28(4), pp.91~99 (2011), 경락경혈학회
- 나창수, "비접촉식 광생체단층촬영 기술을 이용한 맥진 연구 -맥의 빠르기, 크기 및 맥력을 중심으로-", Korean Journal of Acupuncture, 26(2), pp.1~13 (2009), 경락경혈학회
- 백광철, "알기쉬운 맥진학", pp.9~16 (1995), 논장
- 경희대학교 한의과대학 제45기 졸업준비위원회 학술부, "한방진단의 실제적 접근", pp.47~ (1997), 일중사
- 김석하, "전자맥진기의 맥상과 고전의 제맥체상에 관한 연구(I)", 대한한의진단학회지, 13(1), pp.36~44 (2009)
- Light RJ, "Measures of response agreement for qualitative data: Some generalizations and alternatives", Psychological Bulletin, 76(5), pp.365~377 (1971)
- Landis JR, "The measurement of observer agreement for categorical data", Biometrics, 33, pp.159~174 (1977)
- 윤석희, "동의보감", pp.935~ (2005), 동의보감출판사
- 김종열, "맥진기의 문제점과 개선방안에 관한 연구", 대한한의진단학회지, 3(1), pp.28~36 (1999)
- 원재균, "침자극이 좌관맥상과 심박수 미세변화에 미치는 영향", 동의생리병리학회지, 23(1), pp.237~244 (2009), 대한동의병리학회
