논문KCI 등재
근관 성형 전후의 네 가지 전자근관장측정기의 측정 정확성의 비교
In vitro comparison of measurement accuracy in pre-enlarged and enlarged canals with four apex locators
0
조회
0
다운로드
0
인용
0
참고문헌
주제분류치의학
참고문헌 (25)
- Sjo ¨gren U, "Factorsaffecting the long-term results of endodontic treatment", pp.616~618
- Kaufman AY, "Reliability of Root ZX apex locatortested by an in vitro model" (1993)
- Dunlap CA, "An in vivo evaluation of an electronic apex locatorthat uses the ratio method in vital and necrotic canals", 24, pp.48~50 (1998)
- Sunada I, "New method for measuring the length of theroot canal", 41, pp.375~387 (1962)
- McDonald NJ, "An evaluation of the ApexLocator Endocater", pp.5~8
- O’Neill LJ, "A clinical evaluation of electronic rootcanal measurement", pp.469~473 (1974)
- Trope M, "Accuracy of an electronicapex locator under controlled clinical conditions", 1, pp.142~145 (1985)
- Kobayashi C, "New electronic canal measuringdevice based on the ratio method", pp.111~114
- Kobayashi C, "Electronic canal length measurement", 79, pp.226~231 (1995)
- Fouad AF, "Accuracy of theEndex with variations in canal irrigants and foramensize", 19, pp.63~67 (1993)
- Frank AL, "An in vivo evaluation ofEndex electronic apex locator", pp.177~179
- Mayeda DL, "In vivomeasurement accuracy in vital and necrotic canalswith the Endex apex locator", pp.545~548
- Fouad AF, "An in vitro comparison of fiveroot canal length measuring instruments", pp.573~577
- "Operating Instructions of Root ZX J" (1998), Morita MFG Corp
- Kuttler Y, "Microscopic investigation of root apexes", 50, pp.544~552 (1955)
- Tinaz AC, "A simple model todemonstrate the electronic apex locator", 35, pp.940~945 (2002)
- Kaufman AY, "Accuracy of a newapex locator: an in vitro study", 35, pp.186~192 (2002)
- Ounsi HF, "vitro evaluation of the realiabilityof the Root ZX electronic apex locator", 32, pp.120~123 (1999)
- Nguyen HQ, "Electronic length measuring using small and large filesin enlarged canals", 29, pp.359~364 (1996)
- Shabahang S, "An in vivoevaluation of Root ZX electronic apex locator", 11, pp.616~618 (1996)
- Weik AR, "An in vivocomparison of two frequency based electronic apexlocators", 29, pp.497~500 (2003)
- Donnelly IC, "A simplified model to demonstrate theoperation of electronic root canal measuring devices", 19, pp.579~80 (1993)
- Czerw RJ, "An in vitro testof a simplified model to demonstrate the operation ofelectronic root canal measuring devices", pp.605~606 (1994)
- Fouad AF, "A clinical evaluation of five electronic rootcanal length measuring instruments", 16, pp.446~449 (1990)
- Ricard O, "Clinical evaluationof the accuracy of the evident RCM MarkⅡapex locator", pp.567~569
관련 논문AI추천
4종 전자근관장측정기의 정확성과 일관성에 관한 in vitrro연구금기연, 이승종, 조재현대한치과보존학회 · Restorative Dentistry and Endodontics2006 · 제31권 제5호하악 대구치 근심근관에 대한 전자근관장 측정기의 정확도손욱희, 조영린, 황호길대한치과보존학회 · Restorative Dentistry and Endodontics2005 · 제30권 제6호2종 전자근관장측정기의 일관성에 관한 in vitro 연구김의성, 노병덕, 이승종, 황규용대한치과보존학회 · Restorative Dentistry and Endodontics2008 · 제33권 제1호만곡근관에서 근관형성방법에 따른 근관작업장의 변화김성교, 김영경, 조정임, 진명욱대한치과보존학회 · Restorative Dentistry and Endodontics2006 · 제31권 제1호Effect of file size in measuring electronic working length of teeth with open apex조형훈, A-Ra Cho, Ju-Hee Jeong, Ryeon Jin치의학연구원 · Oral Biology Research2022 · 제46권 제1호방사선 미세컴퓨터단층촬영을 이용한 네종류 file systems의 중심유지능에 관한 비교고혜숙, 박동성, 유현미대한치과보존학회 · Restorative Dentistry and Endodontics2007 · 제32권 제1호
이 간행물의 다른 논문 (7건)
수복물의 미세누출도와 변연적합도 측정에 사용되는 방법 사이의 상관 관계 평가신동훈, 황순주pp. 337-343수종의 근관충전재의 열팽창 특성 측정 : Gutta-percha와 Resilon백승호, 배광식, 이인복, 이우철, 전경아pp. 344-351코어용 레진의 두께가 중합에 미치는 영향권병철, 박정원pp. 352-358네 가지 형태의 비우식성 치경부 병소의 3차원 유한요소법적 응력분석우성관, 김광훈, 허복, 박정길, 전상제, 김현철, 손권pp. 359-370Smear layer 처리에 따른 미세누출에 대한 연구박상혁, 이정민, 최기운pp. 378-389
