본문 바로가기
KERD
논문KCI 등재

SLA로 표면처리한 microthreaded crest module 임프란트의 임상적, 조직학적, 조직계측학적 분석

Clinical, histologic, and histometric evaluation of implants with microthreaded crest module and SLA surface

0

조회

0

다운로드

0

인용

0

참고문헌

주제분류치의학

초록

Abstract

Background: Crestal bone loss known as saucerization is a frequently observed phenomenon. Recent studies have shown that implants with micothreaded crest module reduced the force concentration in the crestal region thus resulting in no or reduced crestal bone loss. This study presents a clinical, histologic, and histometric evaluation of implants with microthreaded crest module and SLA surface. Methods: The implants were placed in the mandible of 5 beagle dogs weighing 10-15㎏. Four premolars were bilaterally extracted 8 weeks prior to implant placement. Mucoperiosteal flap was elevated and drilling with increasing diameter was performed under saline irrigation. After countersinking 2 implants were placed in each side resulting in 4 implants per dog. Healing period of 8 weeks was allowed before sacrificing the animals. Histologic preparation was performed for histologic and histometric analysis. Bone to implant contact as well as percentage of bone area inside threads were measured. T-test was used for statistical analysis with p-value p<0.05. Results: 1. Healing was uneventful without any cover screw exposure. New bone formation around the implants was observed without any inflammatory infiltration. 2. Bone to implant contact in the microthread and thread were 43.90 ± 20.30 %, and 53.19 ± 20.97 % respectively. The overall bone to implant contact was 48.54 ± 20.95 %. 3. Percentage of bone area inside threads were 54.43 ± 10.39 %, and 38.44 ± 16.44 % for the microthread and thread respectively. There was statistically significant difference(p<0.05). The overall percentage of bone area inside threads was 46.67 ± 15.68 %

참고문헌 (34)

  1. "Removal torque values of titanium implants in the maxilla of miniature pigs", 13, pp.611~619 (1998)
  2. "Ten-year survival rates of fixed prostheses on four or six implants ad modum Br?nemark in full edentulism", 6, pp.227~231 (1995)
  3. "Histologic and histomorphometric analysis of the bone response to machined and sandblasted titanium implants: An experimental study in rabbits", 13, pp.805~810 (1998)
  4. , 2000, 1202~1203
  5. "Attachment and growth of periodental cells on smooth and rough titanium", pp.289~297 (1994)
  6. "Tissue integration of non-submerged implants 1-year results of a prospective study with 100 ITI hollow-cylinder and hollw-screw implants", pp.33~40 (1990)
  7. "A 3-year follow up study of early single implant restoration ad modum Br?", pp.341~349 (1990), nemark
  8. "Marginal tissue reactions at osseointegrated titanium fixtures", pp.39~52 (1986)
  9. "The longitudinal clinical efficacy of osseointegrated dental implants", pp.91~100 (1987)
  10. "The long-term efficacy of currently used dental implants A review and proposed criteria of success", pp.11~25 (1986)
  11. "Criteria for success of osseointegrated endossous implants", pp.567~572 (1989)
  12. "Radiographic evaluation of crestal one levels adjacent to nonsubmerged titanium implants", pp.181~188 (1992)
  13. "Evaluation of postsurgical crestal bone levels adjacent to non-submerged titanium implants", 9, pp.218~2244 (1998)
  14. "The causes of early implant bone loss Myth or science", 73, pp.322~333 (2002)
  15. "The stress distribution of the hydroxyapatite implant under the vertical load by the two-dimensional finite element method", pp.65~72 (1988)
  16. "finite element analysis of bone around dental implants in an edentulous human mandible Archives in Oral Biology 38", pp.491~496 (1993)
  17. "Mechanical properties of cortical bone and cancellous bone tissue. In: Bone Mechanics Handbook", 10, pp.1~23 (2001), CRC Press 10[DOI]
  18. "Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro- and microstructure", 9, pp.91~99 (1998)
  19. "The influence of various titanium surfaces on the interface shear strength between implants and bone. In:Clinical Implant Materials", 9, pp.309~314, Elsvier Science Publishers
  20. "Bone response to unloadeed and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible", 40, pp.1~11 (1998)
  21. "Effect of titanium surface roughness on proliferation, differentiation, and protein systhesis of human osteoblast-like cells", 29, pp.389~401 (1995)
  22. "Early loading with the ITI SLA surface as a predictable, routine procedure", 3, pp.15~16 (2002)
  23. "Resolution of periimplantitis following treatment. An experimental study in the dog", 10, pp.151~203 (1999)
  24. "Attempts to obtain re-osseointegration following experimental peri-implantitis in dogs", 10, pp.111~119 (1999)
  25. "Re-osseointegration after treatment of peri-implantitis at different implant surfaces", 12, pp.595~603 (2001)
  26. "Mechanical complications of dental implants", 8, pp.156~158 (2000)
  27. "Implants and components: Entering the new millennium", 15, pp.76~94 (2000)
  28. "Implants and components: entering the new millenium", 15, pp.76~94 (2000)
  29. "The implant neck: smooth or provide with retention elements", 10, pp.394~405 (1999)
  30. "A conical implant-abutment interface at the level of the marginal bone improves the distribution of stress in the supporting bone", 14, pp.286~293 (2003)
  31. "Quantified bone tissue reactions to various metallic materials with reference to the so-called osseointegration concept University of Toronto Press 357-363" (1991)
  32. "The excessive loss of Branemark fixtures in type IV bone", pp.2~4 (1991)
  33. "Eary failures in 4 A study from stage I surgery to the connection of completed prostheses", pp.142~146 (1991), 641 consecutively placed Branemark dental implants
  34. "Bone-implnat contact on machined and dual acid-etched surfaces after 2months of healing in the human maxilla", 74, pp.945~956 (2003)

관련 논문AI추천