임플란트 일차 안정성에 있어서 고정체 지름에 따른 osteotome 술식의 효과
The effect of osteotome technique on primary implant stability according to implant fixture diameter
1
조회
0
다운로드
0
인용
0
참고문헌
초록
Abstract
The primary stability of implants is an important factor to predict the osseointegration. Recently, the resonance frequency analysis has been used to measure the primary stability. It is an objective method to monitor the stability of implants during healing phase. This study is to validate the differences in the effect of the osteotome method according to the bone quality as well the thickness of cortical bone. Two hundred seventy implants of 3.75mm in diameter(Neoplant, Neobiotech, Korea) were placed in 135 bovine ribs. The bone quality is classified into 3 classes according to the number of bone marrow spaces which implants would be placed, and then classified into 9 subclasses after the ribs were trimmed. Two implants were placed in 15 specimens of each class. The conclusion were as follows: 1. In case of less dense cancellous bone, the oseotome method is more effective in primary stability rather than the drilling method(p〈0.05). 2. If there was cortical bone, it is more advantagous to get stronger primary stability. 3. If cancellous bone is more dense or if cortical bone exists, there is no statistical signi- ficance between drilling and osteotome method(p〈0.05).
참고문헌 (47)
- "Osseo- integrated implants in the treatment of partially edentulous patients:a prelimi- nary study on 876 consecutively placed fixtures", 4, pp.211~217 (1989)
- "Oral implant treat- ment in posterior partially edentulous jaws:a 5-year follow-up report", 8, pp.635~640 (1993)
- "Survial of the Brnemark implant in partially edentulous jaw:a 10-year prospective multicenter study", 14, pp.639~45 (1999)
- "Long- term results after placement of dental implants:longitudinal study of 1964 im- plants over 16 year", 14, pp.748~755 (1999)
- "The long-term efficacy of currently used dental implants.A review and proposed criteria of success", 1, pp.11~25 (1986)
- "Titanium implant.Require- ments for ensuring a long-lasting direct bone anchorage in man", 52, pp.155~170 (1981)
- "A Swedish multicenter study of 8139 Conse- cutively inserted Nobelpharma implants", pp.287~96
- "The excessive loss of Brnemark fixtures in type IV bone", pp.2~4
- "Early failures in 4 a study from stage 1 surgery to the connection of com- pleted prostheses", pp.142~6, 641 consecutively placed Brnemark dental implants
- "Resonance requency mea- surements of implant stability in vivo.A cross-sectioinal and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla", 8, pp.226~33 (1997)
- "Perio- test--a new measurement process for periodontal function", pp.1229 1233 1239~30 6 40
- "Mechanical state assessment of the implant-bone conti- nuum a better understanding of the Periotest method", pp.43~9 (1995)
- "The relationship of some histologic para- meters and Periotest measurements of oral implants", pp.380~386 (1997)
- "Damping chracteristics of bone-to- implant interaction A clinical study with the Periotest", pp.31~39 (1995)
- "The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia.Clin Oral Implants Res", 8, pp.234~43 (1997)
- "Stability measure- ments of one-stage Brnemark implants during healing in mandibles", pp.266~72 (1999)
- "Implant stability measure- ments using resonance frequency analysis in the grafted maxilla", pp.70~4 (1999)
- "Quan- titative determination of the stability of the implant-tissue interface using reso- nance frequency analysis", 7, pp.261~7 (1996)
- "Assessment of implant sta- bility as a prognositc determinant", 11, pp.491~501 (1998)
- "Resonance fre- quency analysis", pp.493~502 (1998)
- "Pathogenesis of implant failures", 4, pp.127~138 (1994)
- "Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws", 5, pp.347~359 (1990)
- "The excessive loss of Brnemark fixtures in type IV bone", pp.2~4 (1991)
- "A new concept in maxillary implant surgery", pp.152~158 (1994)
- "The osteotome technique", pp.422~426 (1994)
- "Part 3-Less invasive methods of elevating the sinus floor", pp.698~704 (1994)
- "The osteotome technique: Part 4-Future site development", pp.1080~1092 (1995)
- "Biological and bio- mechanical evaluation of bone remo- delling and implant stability after using an osteotome technique", pp.1~8 (2005)
- "Histomorphometric and fluorescence microscopic analysis of bone remodelling after installation of implants using an osteotome technique", 13(6), pp.595~602 (2002)
- "The osteotome technique-A different method of implant placement in the posterior maxilla", 2, pp.103~120 (1998)
- "A 15-year study of osseoin- tegrated implants in the treatment of the edentulous jaw", 10(6), pp.387~416 (1981), Brne- mark PI
- "A multicenter study of over- dentures supported by Brnemark im- plants", 7(4), pp.513~22 (1992)
- "Implant treatment in edentulous maxillae:A 5-year follow-up report on patients with different degrees of jaw resorption", 10, pp.303~311 (1995)
- "Treatment planning and place- ment on implants in the posterior maxil- lae:Report of 732 consecutive Nobel- pharma implants", 8, pp.151~161 (1993)
- "A 15 year study of osseointe- grated implants in the treatment of edentulous jaw", 10, pp.387~416 (1981)
- "Bone response to unloaded and loaded titanium implnats with a sandblasted and acid-etched sur- face:A histometric study in the canine mandible", 40, pp.1~11 (1998)
- "A comparison of endosseous dental implant surfaces", pp.1523~39 (1999)
- "Sinus floor elevation with osteotomes", pp.164~71 (1998)
- "The use of osteotomes for sinus augmentation at the time of implant placement", 18(5), pp.441~7 (1997)
- "Measurements comparing the initial sta- bility of five designs of dental implants", 2(2), pp.85~92 (2000)
- "Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants", 15(4), pp.474~80 (2004)
- "Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading", pp.428~34 (2004)
- "Early detection of implant healing process using resonance frequency analysis", 14, pp.437~43 (2003)
- "Resonance frequency assessment of dental implant stability with various bone quali- ties:a numerical approach", 13, pp.65~74 (2002)
- "Predicting osseo- integration by means of implant primary stability", 15(5), pp.520~8 (2004)
- "A morphometric and biomechanic compa- rison of titanium implants inserted in rabbit cortical and cancellous bone", 7(1), pp.62~71 (1992)
- "A morphometric and biomechanic compa- rison of titanium implants inserted in rabbit cortical and cancellous bone", pp.62~71 (1992)
