Purpose: The objective of this study was to compare initial implant stability measured by RFA between different implant systems during the initial healing period. Material and Methods: Fifty-four patients (36 males/18 females) who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital during the period between January and November in 2007 were included in the study. The mean age of the subjects was 49 years old (18 to 77). A total of 104 implants (Type A: 3i Osseotite®, Type B: Replace® select, Type C: ITI implant) were placed following the manufacturer's standard surgical protocols. Implant stability quotient (ISQ) readings were obtained for each implant at the time of surgery, 2-, and 4-month postoperatively. Result: No implant was failed during the observation period. At the baseline, the difference between mean ISQ values of 3 implant systems was statistically significant (p<0.05). However, at 2-, and 4-month following implant surgery, no significant difference was observed between ISQ values of the implant systems. In the same implant, the ISQ values of Type B and C implants increased (p<0.05), but those of Type A implants decreased during the 2-month healing period. The mean ISQ values of Type B and C implants showed a increasing tendency, while those of Type A implants were stable for the 4-month follow-up period. Conclusion: Within limits of this study, it can be concluded that implant design and surface topography of implant might influence the ISQ value and changing pattern during the initial healing period. (J Korean Acad Periodontol 2008;38:529-534)

Abstract

Purpose: The objective of this study was to compare initial implant stability measured by RFA between different implant systems during the initial healing period. Material and Methods: Fifty-four patients (36 males/18 females) who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital during the period between January and November in 2007 were included in the study. The mean age of the subjects was 49 years old (18 to 77). A total of 104 implants (Type A: 3i Osseotite®, Type B: Replace® select, Type C: ITI implant) were placed following the manufacturer's standard surgical protocols. Implant stability quotient (ISQ) readings were obtained for each implant at the time of surgery, 2-, and 4-month postoperatively. Result: No implant was failed during the observation period. At the baseline, the difference between mean ISQ values of 3 implant systems was statistically significant (p<0.05). However, at 2-, and 4-month following implant surgery, no significant difference was observed between ISQ values of the implant systems. In the same implant, the ISQ values of Type B and C implants increased (p<0.05), but those of Type A implants decreased during the 2-month healing period. The mean ISQ values of Type B and C implants showed a increasing tendency, while those of Type A implants were stable for the 4-month follow-up period. Conclusion: Within limits of this study, it can be concluded that implant design and surface topography of implant might influence the ISQ value and changing pattern during the initial healing period. (J Korean Acad Periodontol 2008;38:529-534)

참고문헌 (30)

  1. Brånemark PI, "osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period", Scand J Plast Reconst Surg, 11(16), pp.1~32 (1977)
  2. Albrektsson, T., "Consensus report of session V. IN Proceedings of the 1st European workshop on periodontology", pp.365~369 (1994), Quintessence Publ. Co.
  3. Szmucler-Moncler S, "Dubruille JH. Consideration preliminary to the application of early and immediate loading protocols in dental implantology", Clin Oral Implants Res, 11, pp.12~25 (2000)
  4. Degidi M, "Immediate functional and non functional loading of dental implants: a 2- to 60- month follow-up study of 646 titanium implants", J Periodontol, 74, pp.225~241 (2003)
  5. Adell, R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", International Journal of Oral Surgery, 10, pp.387~416 (1981)
  6. Meredith, N, "Assessment of implant stability as a prognostic determinant", International Journal of Prosthodontics, 11, pp.491~501 (1998)
  7. Friberg, B, "Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study", International Journal of Oral & Maxillofacial Surgery, 28, pp.266~272 (1999)
  8. Sunden S, "Accuracy and precision in the radiographic diagnosis of clinical instability in Brånemark dental implants", Clin Oral Implants Res, 6, pp.220~226 (1995)
  9. Albreksson, T, "Bone-metal interface in osseointegration", Journal of Prosthetic Dentistry, 57, pp.597~607 (1987)
  10. Carlsson, L, "Removal torques for polished and rough titanium implants", International journal of Oral and Maxillofacial Implants, 3, pp.21~24 (1988)
  11. Olivé, J, "Periotest method as a measure of osseointegrated oral implant stability", International Journal of Oral and Maxillofacial Implants, 5, pp.390~400 (1990)
  12. Caulier, H, "The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: an experimental animal study", International journal of oral and maxillofacial implants, 3, pp.380~386 (1997)
  13. Derhami, Kl, "Assessment of the periotest device in baseline mobility measurements of craniofacial implants", International journal of oral and maxillofacial implants, 10, pp.221~229 (1995)
  14. Meredith N, "Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis", Clin Oral Implants Res, 7, pp.261~267 (1996)
  15. Glauser R, "Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants", Clin Oral Implants Res, 15, pp.428~434 (2004)
  16. Cochran DL, "The use of reduced healing times on ITI implants with a sandblasted and acid etched surface: Early results from clinical trials on ITI SLA implants", Clin Oral Implants Res, 13, pp.144~153 (2002)
  17. Buser D, "Influence of surface characteristics on bone integration of titanium implants. A histometric study in miniature pigs", J Biomed Mater Res, 25, pp.889~902 (1991)
  18. Romeo E, "Implant-retained mandibular overdentures with ITI implants", Clin Oral Implants Res, 13, pp.495~501 (2002)
  19. Ersanli S, "Resonance frequency analysis one-stage dental implant stability during the osseointegration period", J Periodontol, 76, pp.1066~1071 (2005)
  20. Valderrama P, "Evaluation of two different resonance frequency devices to detect implant stability: A clinical trial", J periodontol, 78, pp.262~272 (2007)
  21. Meredith N, "Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla", Clin Oral Implants Res, 8, pp.226~233 (1997)
  22. Zix J, "Stability measurements of 1-staged implants in the maxilla by means resonance frequency analysis: A pilot study", Int J Oral Maxillofac Implants, 20, pp.747~752 (2005)
  23. Barewal RM, "Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface", Int J Oral Maxillofac Implants, 18, pp.641~651 (2003)
  24. Cochran KL, "Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible", J Biomed Mater Res, 40, pp.1~11 (1988)
  25. Roberts W, "Bone tissue interface", J Dent Educ, 52(12), pp.804~809 (1988)
  26. OʼSullivan D, "Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants", Clin Oral Implants Res, 15, pp.474~480 (2004)
  27. OʼSullivan D, "Measurements comparing the initial stability of five designs of dental implants: a human cadaver study", Clin Oral Implants Res, 2, pp.85~92 (2000)
  28. Davies JE, "Mechanism of endosseous integration", Int J Prosthodont, 11, pp.391~401 (1998)
  29. Huwiler MA, "Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation", Clin Oral Implants Res, 18, pp.275~280 (2007)
  30. Nedir R, "Predicting osseointegration by means of implant primary stability. A resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants", Clin Oral Implants Res, 15, pp.520~528 (2003)

관련 논문AI추천

이 간행물의 다른 논문 (16건)