Bone apposition on implants coated with calcium phosphate by ion beam assisted deposition in oversized drilled sockets: a histologic and histometric analysis in dogs
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: The purpose of this study was to evaluate the osseointegration of calcium phosphate (CaP)-coated implants by ion beam assisted deposition with a lack of primary stability. Methods: A total of 20 CaP-coated implants were bilaterally placed in the mandible of five dogs. In the rotational implant group, the implants were inserted in oversized drilled sockets without mechanical engagement, while the conventional surgical protocol was followed in the control group. Each group was allowed to heal for 4 and 8 weeks. The bone-to-implant contact (BIC, %) was measured by a histometric analysis. Results: All of the implants were well-maintained and healing was uneventful. In the histologic observation, all of the implants tested were successfully osseointegrated with a high level of BIC at both observation intervals. There was no significant difference in BIC among any of the groups. Conclusions: Within the limitation of this study, successful osseointegration of CaP-coated implants could be achieved in unfavorable conditions without primary stability.
Abstract
Purpose: The purpose of this study was to evaluate the osseointegration of calcium phosphate (CaP)-coated implants by ion beam assisted deposition with a lack of primary stability. Methods: A total of 20 CaP-coated implants were bilaterally placed in the mandible of five dogs. In the rotational implant group, the implants were inserted in oversized drilled sockets without mechanical engagement, while the conventional surgical protocol was followed in the control group. Each group was allowed to heal for 4 and 8 weeks. The bone-to-implant contact (BIC, %) was measured by a histometric analysis. Results: All of the implants were well-maintained and healing was uneventful. In the histologic observation, all of the implants tested were successfully osseointegrated with a high level of BIC at both observation intervals. There was no significant difference in BIC among any of the groups. Conclusions: Within the limitation of this study, successful osseointegration of CaP-coated implants could be achieved in unfavorable conditions without primary stability.
참고문헌 (24)
- Albrektsson T, "Osseointegrated dental implants", Dent Clin North Am, 30, pp.151~174 (1986)
- Branemark PI, "Osseointegration and its experimental background", J Prosthet Dent, 50, pp.399~410 (1983)
- Cochran DL, "A comparison of endosseous dental implant surfaces", J Periodontol, 70, pp.1523~1539 (1999)
- Botticelli D, "The jumping distance revisited : an experimental study in the dog", Clin Oral Implants Res, 14, pp.35~42 (2003)
- Botticelli D, "Resolution of bone defects of varying dimension and configuration in the marginal portion of the peri-implant bone. An experimental study in the dog", J Clin Periodontol, 31, pp.309~317 (2004)
- Botticelli D, "Bone regeneration at implants with turned or rough surfaces in self-contained defects : an experimental study in the dog", J Clin Periodontol, 32, pp.448~455 (2005)
- Junker R, "Effects of implant surface coatings and composition on bone integration : a systematic review", Clin Oral Implants Res, 20(4), pp.185~206 (2009)
- Shalabi MM, "Implant surface roughness and bone healing : a systematic review", J Dent Res, 85, pp.496~500 (2006)
- 정의원, "Surface characteristics of a novel hydroxyapatite-coated dental implant", Journal of Periodontal & Implant Science, 42(2), pp.59~63 (2012), 대한치주과학회[DOI]
- Lacefield WR, "Hydroxyapatite coatings", Ann N Y Acad Sci, 523, pp.72~80 (1988)
- Hayashi K, "Comparison of bone-implant interface shear strength of solid hydroxyapatite and hydroxyapatite-coated titanium implants", J Biomed Mater Res, 27, pp.557~563 (1993)
- van Dijk K, "Influence of discharge power level on the properties of hydroxyapatite films deposited on Ti6A14V with RF magnetron sputtering", J Biomed Mater Res, 29, pp.269~276 (1995)
- Lee IS, "Industrial application of ion beam assisted deposition on medical implants", Surf Coat Technol, 201, pp.5132~5137 (2007)
- Wikesjo UM, "The critical-size supraalveolar peri-implant defect model : characteristics and use", J Clin Periodontol, 33, pp.846~854 (2006)
- Jung UW, "Healing of surgically created circumferential gap around non-submerged-type implants in dogs : a histomorphometric study", Clin Oral Implants Res, 18, pp.171~178 (2007)
- Davies JE, "Understanding peri-implant endosseous healing", J Dent Educ, 67, pp.932~949 (2003)
- Sivolella S, "Osteogenesis at implants without primary bone contact : an experimental study in dogs", Clin Oral Implants Res, 23, pp.542~549 (2012)
- Araujo MG, "An experimental study in the dog", J Clin Periodontol, 32, pp.212~218 (2005)
- Lazzara RJ, "Immediate implant placement into extraction sites : surgical and restorative advantages", Int J Periodontics Restorative Dent, 9, pp.332~343 (1989)
- Stadlinger B, "Systematic review of animal models for the study of implant integration, assessing the influence of material, surface and design", J Clin Periodontol, 12, pp.28~36 (2012)
- Chae GJ, "Healing of surgically created circumferential gap around nano-coating surface dental implants in dogs", Surf Interface Anal, 40, pp.184~187 (2008)
- Jung UW, "Osseointegration of dental implants installed without mechanical engagement : a histometric analysis in dogs", Clin Oral Implants Res, 23, pp.1297~1301 (2012)
- Song JE, "The effect of a multi-treated implant surface on gap defect healing in dogs", Thin Solid Films, 517, pp.5352~5356 (2009)
- Um YJ, "The effect of post heat treatment of hydroxyapatite-coated implants on the healing of circumferential coronal defects in dogs", Thin Solid Films, 517, pp.5375~5379 (2009)