The effects of physical decontamination methods on zirconia implant surfaces: a systematic review
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose: Peri-implantitis therapy and implant maintenance are fundamental practices to enhance the longevity of zirconia implants. However, the use of physical decontamination methods, including hand instruments, polishing devices, ultrasonic scalers, and laser systems, might damage the implant surfaces. The aim of this systematic review was to evaluate the effects of physical decontamination methods on zirconia implant surfaces. Methods: A systematic search was conducted using 5 electronic databases: Ovid MEDLINE, PubMed, Scopus, Web of Science, and Cochrane. Hand searching of the OpenGrey database, reference lists, and 6 selected dental journals was also performed to identify relevant studies satisfying the eligibility criteria. Results: Overall, 1049 unique studies were identified, of which 11 studies were deemed suitable for final review. Air-abrasive devices with glycine powder, prophylaxis cups, and ultrasonic scalers with non-metal tips were found to cause minimal to no damage to implant-grade zirconia surfaces. However, hand instruments and ultrasonic scalers with metal tips have the potential to cause major damage to zirconia surfaces. In terms of laser systems, diode lasers appear to be the most promising, as no surface alterations were reported following their use. Conclusion: Air-abrasive devices and prophylaxis cups are safe for zirconia implant decontamination due to preservation of the implant surface integrity. In contrast, hand instruments and ultrasonic scalers with metal tips should be used with caution. Recommendations for the use of laser systems could not be fully established due to significant heterogeneity among included studies, but diode lasers may be the best-suited system. Further research—specifically, randomised controlled trials—would further confirm the effects of physical decontamination methods in a clinical setting.
Abstract
Purpose: Peri-implantitis therapy and implant maintenance are fundamental practices to enhance the longevity of zirconia implants. However, the use of physical decontamination methods, including hand instruments, polishing devices, ultrasonic scalers, and laser systems, might damage the implant surfaces. The aim of this systematic review was to evaluate the effects of physical decontamination methods on zirconia implant surfaces. Methods: A systematic search was conducted using 5 electronic databases: Ovid MEDLINE, PubMed, Scopus, Web of Science, and Cochrane. Hand searching of the OpenGrey database, reference lists, and 6 selected dental journals was also performed to identify relevant studies satisfying the eligibility criteria. Results: Overall, 1049 unique studies were identified, of which 11 studies were deemed suitable for final review. Air-abrasive devices with glycine powder, prophylaxis cups, and ultrasonic scalers with non-metal tips were found to cause minimal to no damage to implant-grade zirconia surfaces. However, hand instruments and ultrasonic scalers with metal tips have the potential to cause major damage to zirconia surfaces. In terms of laser systems, diode lasers appear to be the most promising, as no surface alterations were reported following their use. Conclusion: Air-abrasive devices and prophylaxis cups are safe for zirconia implant decontamination due to preservation of the implant surface integrity. In contrast, hand instruments and ultrasonic scalers with metal tips should be used with caution. Recommendations for the use of laser systems could not be fully established due to significant heterogeneity among included studies, but diode lasers may be the best-suited system. Further research—specifically, randomised controlled trials—would further confirm the effects of physical decontamination methods in a clinical setting.
참고문헌 (46)
- Stanford CM, "Dental implants. A role in geriatric dentistry for the general practice?", J Am Dent Assoc, 138(Suppl), pp.34S~40S (2007)
- Özkurt Z, "Zirconia dental implants : a literature review", J Oral Implantol, 37, pp.367~376 (2011)
- Apratim A, "Zirconia in dental implantology : a review", J Int Soc Prev Community Dent, 5, pp.147~156 (2015)
- Kim KT, "General review of titanium toxicity", Int J Implant Dent, 5, pp.10~ (2019)
- Sivaraman K, "Is zirconia a viable alternative to titanium for oral implant? A critical review", J Prosthodont Res, 62, pp.121~133 (2018)
- Roehling S, "Zirconia compared to titanium dental implants in preclinical studies-a systematic review and meta-analysis", Clin Oral Implants Res, 30, pp.365~395 (2019)
- Klinge B, "Peri-implant diseases", Eur J Oral Sci, 126(Suppl 1), pp.88~94 (2018)
- Caton JG, "A new classification scheme for periodontal and peri-implant diseases and conditions-Introduction and key changes from the 1999classification", J Clin Periodontol, 45(Suppl 20), pp.S1~8 (2018)
- Prathapachandran J, "Management of peri-implantitis", Dent Res J(Isfahan), 9, pp.516~521 (2012)
- Atieh MA, "The frequency of peri-implant diseases : a systematic review and meta-analysis", J Periodontol, 84, pp.1586~1598 (2013)
- Dhir S, "Biofilm and dental implant : The microbial link", J Indian Soc Periodontol, 17, pp.5~11 (2013)
- Nicola Alberto Valente, "Peri-implant disease: what we know and what we need to know", Journal of Periodontal & Implant Science, 46(3), pp.136~151 (2016), 대한치주과학회
- Heitz-Mayfield LJ, "Diagnosis and management of peri-implant diseases", Aust Dent J, 53(Suppl 1), pp.S43~48 (2008)
- Teughels W, "Effect of material characteristics and", or surface topography on biofilm development, 2006, pp.17(Suppl 2), 68~81
- Subramani K, "Biofilm on dental implants : a review of the literature", Int J Oral Maxillofac Implants, 24, pp.616~626 (2009)
- Guarnieri R, "Comparative results of single implants with and without laser-microgrooved collar placed and loaded with different protocols : a long-term(7 to 10 years)retrospective multicenter study", Int J Oral Maxillofac Implants, 35, pp.841~849 (2020)
- Al-Hashedi AA, "Decontamination of titanium implants using physical methods", Clin Oral Implants Res, 28, pp.1013~1021 (2017)
- Louropoulou A, "Titanium surface alterations following the use of different mechanical instruments : a systematic review", Clin Oral Implants Res, 23, pp.643~658 (2012)
- Louropoulou A, "The effects of mechanical instruments on contaminated titanium dental implant surfaces : a systematic review", Clin Oral Implants Res, 25, pp.1149~1160 (2014)
- Moher D, "Preferred reporting items for systematic reviews and meta-analyses : the PRISMA statement", PLoS Med, 6, pp.e1000097~ (2009)
- "Effect of physical decontamination methods on zirconia implant surfaces: a systematic review (PROSPERO protocol No. CRD42020173316)" (2020)[URL]
- Faggion CM Jr, "Guidelines for reporting pre-clinical in vitro studies on dental materials", J Evid Based Dent Pract, 12, pp.182~189 (2012)
- Luo JD, "The effect of non-steroidal anti-inflammatory drugs on the osteogenic activity in osseointegration : a systematic review", Int J Implant Dent, 4, pp.30~ (2018)
- Atkins D, "Grading quality of evidence and strength of recommendations", BMJ, 328, pp.1490~ (2004)
- Alhaidary D, "Surface roughness alterations of zirconia implants after Er:YAG laser irradiation: a preliminary study", Lasers in Dental Science, 3, pp.269~273 (2019)
- Checketts MR, "An investigation of the effect of scaling-induced surface roughness on bacterial adhesion in common fixed dental restorative materials", J Prosthet Dent, 112, pp.1265~1270 (2014)
- Huang YS, "Surface changes and bacterial adhesion on implant abutment materials after various clinical cleaning procedures", J Chin Med Assoc, 82, pp.643~650 (2019)
- Kushima SS, "Evaluation of temperature and roughness alteration of diode laser irradiation of zirconia and titanium for peri-implantitis treatment", Photomed Laser Surg, 34, pp.194~199 (2016)
- Lang MS, "Cell attachment following instrumentation with titanium and plastic instruments, diode laser, and titanium brush on titanium, titanium-zirconium, and zirconia surfaces", Int J Oral Maxillofac Implants, 31, pp.799~806 (2016)
- Miranda PV, "Surface alterations of zirconia and titanium substrates after Er,Cr:YSGG irradiation", Lasers Med Sci, 30, pp.43~48 (2015)
- Nakazawa K, "Surface properties of dental zirconia ceramics affected by ultrasonic scaling and low-temperature degradation", PLoS One, 13, pp.e0203849~ (2018)
- Seol HW, "Surface alterations of several dental materials by a novel ultrasonic scaler tip", Int J Oral Maxillofac Implants, 27, pp.801~810 (2012)
- Stübinger S, "Effect of Er:YAG, CO2 and diode laser irradiation on surface properties of zirconia endosseous dental implants", Lasers Surg Med, 40, pp.223~228 (2008)
- Vigolo P, "An in vitro evaluation of alumina, zirconia, and lithium disilicate surface roughness caused by two scaling instruments", J Prosthodont, 26, pp.129~135 (2017)
- Vigolo P, "An in vitro evaluation of zirconia surface roughness caused by different scaling methods", J Prosthet Dent, 103, pp.283~287 (2010)
- Javad Tavakoli, "Surface morphology characterization of laser-induced titanium implants: lesson to enhance osseointegration process", Biomedical Engineering Letters (BMEL), 8(3), pp.249~257 (2018), 대한의용생체공학회
- Rosa MB, "The influence of surface treatment on the implant roughness pattern", J Appl Oral Sci, 20, pp.550~555 (2012)
- Rashid H, "Evaluation of the surface roughness of a standard abraded dental porcelain following different polishing techniques", J Dent Sci, 7, pp.184~189 (2012)
- Renvert S, "Diagnosis and nonsurgical treatment of peri-implant diseases and maintenance care of patients with dental implants-Consensus report of working group 3", Int Dent J, 69(Suppl 2), pp.12~17 (2019)
- Lollobrigida M, "The prevention of implant surface alterations in the treatment of peri-implantitis : comparison of three different mechanical and physical treatments", Int J Environ Res Public Health, 17, pp.2624~ (2020)
- Louropoulou A, "Influence of mechanical instruments on the biocompatibility of titanium dental implants surfaces : a systematic review", Clin Oral Implants Res, 26, pp.841~850 (2015)
- Sanon C, "Low temperature degradation and reliability of one-piece ceramic oral implants with a porous surface", Dent Mater, 29, pp.389~397 (2013)
- Renvert S, "How do implant surface characteristics influence peri-implant disease?", J Clin Periodontol, 38(Suppl 11), pp.214~222 (2011)
- Bollen CM, "The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis", Clin Oral Implants Res, 7, pp.201~211 (1996)
- Kotsakis GA, "Systematic review and meta-analysis of the effect of various laser wavelengths in the treatment of peri-implantitis", J Periodontol, 85, pp.1203~1213 (2014)
- García JC, "Some considerations about the use of contact and confocal microscopy methods in surface texture measurement", Materials(Basel), 11, pp.1484~ (2018)