Multi-condition optimization and experimental verification of impeller for a marine centrifugal pump
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
In order to improve the performance of marine centrifugal pump, a centrifugal pump whose specific speed is 66.7 was selected for the research. Outlet diameter D2, outlet width b2, blade outlet angle b2, blade wrap 4 and blade number z of the impeller were chosen as the variables. The maximum weighted average efficiency and the minimum vibration intensity at the base were calculated as objectives. Based on the Latin Hypercube method, the impeller was numerically optimized. The numerical results show that after optimization, the amplitudes of pressure fluctuation on the main frequency at different monitoring points decrease in varying degrees. The radial force on impeller decreases obviously under off-design flow rates and is more symmetrical during the operation of the pump. The variation of the axial force is relatively small, which has no obvious relationship with the rotating angle of the impeller. The energy performance and vibration experiment was performed for verifying. The test results show that the weighted average efficiency under 0.8Qd, 1.0Qd and 1.2Qd increases by 4.3% after optimization. The maximal vibration intensity at M1-M4 on the pump base reduced from 0.36 mm/s to 0.25 mm/s, decreasing by 30.5%. In addition, the vibration velocities of bracket in pump side and outlet flange also have significant reductions.
Abstract
In order to improve the performance of marine centrifugal pump, a centrifugal pump whose specific speed is 66.7 was selected for the research. Outlet diameter D2, outlet width b2, blade outlet angle b2, blade wrap 4 and blade number z of the impeller were chosen as the variables. The maximum weighted average efficiency and the minimum vibration intensity at the base were calculated as objectives. Based on the Latin Hypercube method, the impeller was numerically optimized. The numerical results show that after optimization, the amplitudes of pressure fluctuation on the main frequency at different monitoring points decrease in varying degrees. The radial force on impeller decreases obviously under off-design flow rates and is more symmetrical during the operation of the pump. The variation of the axial force is relatively small, which has no obvious relationship with the rotating angle of the impeller. The energy performance and vibration experiment was performed for verifying. The test results show that the weighted average efficiency under 0.8Qd, 1.0Qd and 1.2Qd increases by 4.3% after optimization. The maximal vibration intensity at M1-M4 on the pump base reduced from 0.36 mm/s to 0.25 mm/s, decreasing by 30.5%. In addition, the vibration velocities of bracket in pump side and outlet flange also have significant reductions.
참고문헌 (14)
- Benturki, M., "Multi-objective optimization of twostage centrifugal pump using NSGA-II algorithm", J. Appl. Fluid Mech, 11(4), pp.929~943 (2018)
- Liu, H. L., "Multicondition optimization and experimental measurements of a double-blade centrifugal pump impeller", Journal of Fluids Engineering - Transactions of the ASME, 135(1) (2013)
- Lu, X. Y., "Numerical optimization for radiated noises of centrifugal pumps in the near-field and far-field based on a novel MLGA-PSO algorithm", Journal of Vibroengineering, 19(7), pp.5589~5605 (2017)
- Nourbakhsh, A., "The comparison of multiobjective particle swarm optimization and NSGA II algorithm : applications in centrifugal pumps", Eng. Optim, 43(10), pp.1095~1113 (2011)
- Ji Pei, "Multi-point optimization on meridional shape of a centrifugal pump impeller for performance improvement", Journal of Mechanical Science and Technology, 30(11), pp.4949~4960 (2016), 대한기계학회
- Safikhani, H., "Pareto based multi-objective optimization of centrifugal pumps using CFD, Neural Networks and Genetic algorithms", Engineering Applications of Computational Fluid Mechanics, 5(1), pp.48~ (2011)
- Shim, H. S., "Three-objective optimization of a centrifugal pump with double volute to minimize radial thrust at off-design conditions", Proc Inst Mech Eng A J Power Energy, 230(6), pp.598~615 (2016)
- Shim, H. S., "Three-objective optimization of a centrifugal pump to reduce flow recirculation and cavitation", Journal of Fluids Engineering - Transactions of the ASME, 140(9) (2018)
- Tao, R., "Multi-objective optimization of double suction centrifugal pump", Proc. Inst. Mech. Eng. C J. Mech. Eng. Sci, 232(6), pp.1108~1117 (2018)
- Wang, Y. Q., "Multiobjective Optimization Design and Performance Prediction of Centrifugal Pump Based on Orthogonal Test", Adv. Mater. Sci. Eng, 2018, pp.6218178~ (2018)
- Wang, Y. Q., "Multiobjective optimization design and experimental study of desulfurization dust removal centrifugal pump based on Immune Particle Swarm algorithm", Adv. Mater. Sci. Eng (2018)
- Xu, Y., "Multiparameter and multiobjective optimization design of centrifugal pump based on orthogonal method", Proc. Inst. Mech. Eng. C J. Mech. Eng. Sci, 231(14), pp.2569~2579 (2017)
- Zhang, Y., "Multi-objective optimization of double suction centrifugal pump using Kriging metamodels", Adv. Eng. Software, 74, pp.16~26 (2014)
- Zhao, A., "Multi-objective optimization of a low specific speed centrifugal pump using an evolutionary algorithm", Eng. Optim, 48(7), pp.1251~1274 (2016)