Interface between calcium silicate cement and adhesive systems according to adhesive families and cement maturation
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: This study aimed to evaluate the interface between a calcium silicate cement (CSC), Biodentine and dental adhesives in terms of sealing ability. Materials and Methods: Microleakage test: 160 standardized class II cavities were prepared on 80 extracted human molars. The cavities were filled with Biodentine and then divided into 2 experimental groups according to the time of restoration: composite resin obturation 15 minutes after Biodentine handling (D0); restoration after 7 days (D7). Each group was then divided into 8 subgroups (n = 5) according to the adhesive system used: etch-and-rinse adhesive (Prime & Bond); self-etch adhesive 2 steps (Optibond XTR and Clearfil SE Bond); self-etch adhesive 1 step (Xeno III, G-aenial Bond, and Clearfil Tri-S Bond); and universal used as etch-and-rinse or self-etch (ScotchBond Universal ER or SE). After thermocycling, the teeth were immersed in a silver nitrate solution, stained, longitudinally sectioned, and the Biodentine/adhesive percolation was quantified. Scanning electron microscopic observations: Biodentine/adhesive interfaces were observed. Results: A tendency towards less microleakage was observed when Biodentine was etched (2.47%) and when restorations were done without delay (D0: 4.31%, D7: 6.78%), but this was not significant. The adhesives containing 10-methacryloyloxydecyl dihydrogen phosphate monomer showed the most stable results at both times studied. All Biodentine/adhesive interfaces were homogeneous and regular. Conclusions: The good sealing of the CSC/adhesive interface is not a function of the system adhesive family used or the cement maturation before restoration. Biodentine can be used as a dentine substitute.
Abstract
Objectives: This study aimed to evaluate the interface between a calcium silicate cement (CSC), Biodentine and dental adhesives in terms of sealing ability. Materials and Methods: Microleakage test: 160 standardized class II cavities were prepared on 80 extracted human molars. The cavities were filled with Biodentine and then divided into 2 experimental groups according to the time of restoration: composite resin obturation 15 minutes after Biodentine handling (D0); restoration after 7 days (D7). Each group was then divided into 8 subgroups (n = 5) according to the adhesive system used: etch-and-rinse adhesive (Prime & Bond); self-etch adhesive 2 steps (Optibond XTR and Clearfil SE Bond); self-etch adhesive 1 step (Xeno III, G-aenial Bond, and Clearfil Tri-S Bond); and universal used as etch-and-rinse or self-etch (ScotchBond Universal ER or SE). After thermocycling, the teeth were immersed in a silver nitrate solution, stained, longitudinally sectioned, and the Biodentine/adhesive percolation was quantified. Scanning electron microscopic observations: Biodentine/adhesive interfaces were observed. Results: A tendency towards less microleakage was observed when Biodentine was etched (2.47%) and when restorations were done without delay (D0: 4.31%, D7: 6.78%), but this was not significant. The adhesives containing 10-methacryloyloxydecyl dihydrogen phosphate monomer showed the most stable results at both times studied. All Biodentine/adhesive interfaces were homogeneous and regular. Conclusions: The good sealing of the CSC/adhesive interface is not a function of the system adhesive family used or the cement maturation before restoration. Biodentine can be used as a dentine substitute.
참고문헌 (41)
- Bachoo IK, "A biocompatible and bioactive replacement for dentine: Is this a reality? The properties and uses of a novel calcium-based cement", Br Dent J, 214, pp.E5~ (2013)
- Torabinejad M, "Physical and chemical properties of a new root-end filling material", J Endod, 21, pp.349~353 (1995)
- Schwartz RS, "Mineral trioxide aggregate: a new material for endodontics", J Am Dent Assoc, 130, pp.967~975 (1999)
- Torabinejad M, "Mineral trioxide aggregate: a comprehensive literature review--part II: leakage and biocompatibility investigations", J Endod, 36, pp.190~202 (2010)
- Sarkar NK, "Physicochemical basis of the biologic properties of mineral trioxide aggregate", J Endod, 31, pp.97~100 (2005)
- Bozeman TB, "Elemental analysis of crystal precipitate from gray and white MTA", J Endod, 32, pp.425~428 (2006)
- Watson TF, "Present and future of glass-ionomers and calciumsilicate cements as bioactive materials in dentistry: biophotonics-based interfacial analyses in health and disease", Dent Mater, 30, pp.50~61 (2014)
- Atmeh AR, "Dentin-cement interfacial interaction: calcium silicates and polyalkenoates", J Dent Res, 91, pp.454~459 (2012)
- Pradelle-Plasse N, "Biocompatibility or cytotoxic effects of dental composites" (2009), Coxmoor Publishing Company
- Villat C, "Impedance methodology:a new way to characterize the setting reaction of dental cements", Dent Mater, 26, pp.1127~1132 (2010)
- Koubi G, "Clinical evaluation of the performance and safety of a new dentine substitute, Biodentine, in the restoration of posterior teeth - a prospective study", Clin Oral Investig, 17, pp.243~249 (2013)
- Bergenholtz G, "Bacterial leakage around dental restorations: its effect on the dental pulp", J Oral Pathol, 11, pp.439~450 (1982)
- Browne RM, "Microbial microleakage and pulpal inflammation: a review", Endod Dent Traumatol, 2, pp.177~183 (1986)
- Camilleri J, "Investigation of Biodentine as dentine replacement material", J Dent, 41, pp.600~610 (2013)
- Meraji N, "Bonding over dentin replacement materials", J Endod, 43, pp.1343~1349 (2017)
- Hashem DF, "The physical characteristics of resin composite-calcium silicate interface as part of a layered", laminate adhesive restoration, 2014, pp.30, 343~349
- Cengiz E, "Microshear bond strength of tri-calcium silicate-based cements to different restorative materials", J Adhes Dent, 18, pp.231~237 (2016)
- Çolak H, "The effect of different adhesives and setting times on bond strength between Biodentine and composite", J Appl Biomater Funct Mater, 14, pp.e217~e222 (2016)
- Odabaş ME, "Shear bond strengths of different adhesive systems to Biodentine", Scientific World Journal, 2013, pp.626103~ (2013)
- Abraham SB, "Cavity adaptation of water-based restoratives placed as liners under a resin composite", Int J Dent, 2017, pp.5957107~ (2017)
- Aggarwal V, "Marginal adaptation evaluation of Biodentine and MTA plus in ‘open sandwich’ class II restorations", J Esthet Restor Dent, 27, pp.167~175 (2015)
- Raskin A, "In vitro microleakage of Biodentine as a dentin substitute compared to Fuji II LC in cervical lining restorations", J Adhes Dent, 14, pp.535~542 (2012)
- Besnault C, "Simulated oral environment and microleakage of class II resin-based composite and sandwich restorations", Am J Dent, 16, pp.186~190 (2003)
- Gale MS, "Thermal cycling procedures for laboratory testing of dental restorations", J Dent, 27, pp.89~99 (1999)
- Cervino G, "Interface between MTA and dental bonding agents: scanning electron microscope evaluation", J Int Soc Prev Community Dent, 7, pp.64~68 (2017)
- Garrault S, "Formation of the C-S-H layer during early hydration of tricalcium silicate grains with different sizes", J Phys Chem B, 110, pp.270~275 (2006)
- Rengo C, "Influence of phosphoric acid etching on microleakage of a self-etch adhesive and a self-adhering composite", Aust Dent J, 57, pp.220~226 (2012)
- Kayahan MB, "Effect of acid-etching procedure on selected physical properties of mineral trioxide aggregate", Int Endod J, 42, pp.1004~1014 (2009)
- Atabek D, "Bond strength of adhesive systems to mineral trioxide aggregate with different time intervals", J Endod, 38, pp.1288~1292 (2012)
- Silva e Souza MH Jr, "Adhesive systems: important aspects related to their composition and clinical use", J Appl Oral Sci, 18, pp.207~214 (2010)
- Karaman E, "Effect of operator variability on microleakage with different adhesive systems", Eur J Dent, 7, pp.S060~S065 (2013)
- Palma PJ, "Does delayed restoration improve shear bond strength of different restorative protocols to calcium silicate-based cements?", Materials (Basel), 11, pp.2216~ (2018)
- Sultana N, "Effect of acid etching on the micro-shear bond strength of resin composite-calcium silicate interface evaluated over different time intervals of bond aging", J Conserv Dent, 21, pp.194~197 (2018)
- Yoshioka M, "Adhesion", decalcification mechanisms of acid interactions with human hard tissues, 2002, pp.59, 56~62
- Yoshida Y, "Comparative study on adhesive performance of functional monomers", J Dent Res, 83, pp.454~458 (2004)
- Carrilho E, "10-MDP based dental adhesives: adhesive interface characterization and adhesive stability-a systematic review", Materials (Basel), 12, pp.790~ (2019)
- Yoshihara K, "Adhesive interfacial interaction affected by different carbon-chain monomers", Dent Mater, 29, pp.888~897 (2013)
- Chatel E, "Degradation mechanisms of modern self–etching adhesives", Clin Oral Investig, 17, pp.1035~ (2013)
- Koubi S, "Quantitative evaluation by glucose diffusion of microleakage in aged calcium silicate-based open-sandwich restorations", Inter J Dent, 2012, pp.105863~ (2012)
- Aksel H, "Surface and vertical dimensional changes of mineral trioxide aggregate and Biodentine in different environmental conditions", J Appl Oral Sci, 27, pp.e20180093~ (2018)
- Agrafioti A, "Comparative evaluation of sealing ability and microstructure of MTA and Biodentine after exposure to different environments", Clin Oral Investig, 20, pp.1535~1540 (2016)
