Clinical evaluation of 3.0-mm narrow-diameter implants: a retrospective study with up to 5 years of observation
1
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Purpose: This study aimed to evaluate the clinical outcomes of a single type of narrow-diameter implant (NDI) by investigating its survival rate and peri-implant marginal bone loss (MBL). In addition, variables possibly related to implant survival and MBL were investigated to identify potential risk factors. Methods: The study was conducted as a retrospective study involving 49 patients who had received 3.0-mm diameter TSIII implants (Osstem Implant Co.) at Seoul National University Dental Hospital. In total, 64 implants were included, and dental records and radiographic data were collected from 2017 to 2022. Kaplan-Meier survival curves and a Cox proportional hazard model were used to estimate the implant survival rate and to investigate the effects of age, sex, jaw, implant location, implant length, the stage of surgery, guided bone regeneration, type of implant placement, and the surgeon’s proficiency (resident or professor) on implant survival. The MBL of the NDIs was measured, and the factors influencing MBL were evaluated. Results: The mean observation period was 30.5 months (interquartile range, 26.75–45 months), and 6 out of 64 implants failed. The survival rate of the NDIs was 90.6%, and the multivariate Cox regression analysis showed that age was associated with implant failure (hazard ratio, 1.17; 95% confidence interval, 1.04–1.31, P=0.01). The mean MBL was 0.44±0.75 mm, and no factors showed statistically significant associations with greater MBL. Conclusions: NDIs can be considered a primary alternative when standard-diameter implants are unsuitable. However, further studies are required to confirm their long-term stability.
Abstract
Purpose: This study aimed to evaluate the clinical outcomes of a single type of narrow-diameter implant (NDI) by investigating its survival rate and peri-implant marginal bone loss (MBL). In addition, variables possibly related to implant survival and MBL were investigated to identify potential risk factors. Methods: The study was conducted as a retrospective study involving 49 patients who had received 3.0-mm diameter TSIII implants (Osstem Implant Co.) at Seoul National University Dental Hospital. In total, 64 implants were included, and dental records and radiographic data were collected from 2017 to 2022. Kaplan-Meier survival curves and a Cox proportional hazard model were used to estimate the implant survival rate and to investigate the effects of age, sex, jaw, implant location, implant length, the stage of surgery, guided bone regeneration, type of implant placement, and the surgeon’s proficiency (resident or professor) on implant survival. The MBL of the NDIs was measured, and the factors influencing MBL were evaluated. Results: The mean observation period was 30.5 months (interquartile range, 26.75–45 months), and 6 out of 64 implants failed. The survival rate of the NDIs was 90.6%, and the multivariate Cox regression analysis showed that age was associated with implant failure (hazard ratio, 1.17; 95% confidence interval, 1.04–1.31, P=0.01). The mean MBL was 0.44±0.75 mm, and no factors showed statistically significant associations with greater MBL. Conclusions: NDIs can be considered a primary alternative when standard-diameter implants are unsuitable. However, further studies are required to confirm their long-term stability.
참고문헌 (39)
- Pjetursson BE, "Improvements in implant dentistry over the last decade : comparison of survival and complication rates in older and newer publications", Int J Oral Maxillofac Implants, 29(Suppl), pp.308~324 (2014)
- Al-Nawas B, "Augmentation procedures using bone substitute materials or autogenous bone-a systematic review and meta-analysis", Eur J Oral Implantology, 7(Suppl 2), pp.S219~S234 (2014)
- Buser D, "Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants", Clin Oral Implants Res, 1, pp.33~40 (1990)
- Nyman S, "Bone regeneration adjacent to titanium dental implants using guided tissue regeneration : a report of two cases", Int J Oral Maxillofac Implants, 5, pp.9~14 (1990)
- Chiapasco M, "Clinical outcomes of GBR procedures to correct peri-implant dehiscences and fenestrations : a systematic review", Clin Oral Implants Res, 20(Suppl 4), pp.113~123 (2009)
- Degidi M, "Clinical outcome of narrow diameter implants : a retrospective study of 510 implants", J Periodontol, 79, pp.49~54 (2008)
- Romeo E, "Clinical and radiographic evaluation of small-diameter(3. 3-mm)implants followed for 1-7 years : a longitudinal study", Clin Oral Implants Res, 17, pp.139~148 (2006)
- Vigolo P, "Clinical evaluation of small-diameter implants in single-tooth and multiple-implant restorations : a 7-year retrospective study", Int J Oral Maxillofac Implants, 19, pp.703~709 (2004)
- Zinsli B, "Clinical evaluation of small-diameter ITI implants : a prospective study", Int J Oral Maxillofac Implants, 19, pp.92~99 (2004)
- Klein MO, "Systematic review on success of narrow-diameter dental implants", Int J Oral Maxillofac Implants, 29(Suppl), pp.43~54 (2014)
- Bidra AS, "Mini implants for definitive prosthodontic treatment : a systematic review", J Prosthet Dent, 109, pp.156~164 (2013)
- Schiegnitz E, "Narrow-diameter implants : a systematic review and meta-analysis", Clin Oral Implants Res, 29(Suppl 16), pp.21~40 (2018)
- Cruz RS, "Narrow-diameter implants versus regular-diameter implants for rehabilitation of the anterior region : a systematic review and meta-analysis", Int J Oral Maxillofac Implants, 50, pp.674~682 (2021)
- Petrie CS, "Comparative evaluation of implant designs : influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis", Clin Oral Implants Res, 16, pp.486~494 (2005)
- Quek CE, "Load fatigue performance of a single-tooth implant abutment system : effect of diameter", Int J Oral Maxillofac Implants, 21, pp.929~936 (2006)
- Lee JS, "Long-term retrospective study of narrow implants for fixed dental prostheses", Clin Oral Implants Res, 24, pp.847~852 (2013)
- Ivanoff CJ, "Influence of implant diameters on the integration of screw implants. An experimental study in rabbits", Int J Oral Maxillofac Surg, 26, pp.141~148 (1997)
- Hämmerle CH, "Consensus statements and recommended clinical procedures regarding the placement of implants in extraction sockets", Int J Oral Maxillofac Implants, 19(Suppl), pp.26~28 (2004)
- Andersen E, "A prospective clinical study evaluating the safety and effectiveness of narrow-diameter threaded implants in the anterior region of the maxilla", Int J Oral Maxillofac Implants, 16, pp.217~224 (2001)
- Moráguez O, "Four-unit fixed dental prostheses replacing the maxillary incisors supported by two narrow-diameter implants-a five-year case series", Clin Oral Implants Res, 28, pp.887~892 (2017)
- Woo IH, "Narrow-diameter implants with conical connection for restoring the posterior edentulous region", Maxillofac Plast Reconstr Surg, 38, pp.31~ (2016)
- Zweers J, "Clinical and radiographic evaluation of narrow-vs. regular-diameter dental implants : a 3-year follow-up. A retrospective study", Clin Oral Implants Res, 26, pp.149~156 (2015)
- Zupnik J, "Factors associated with dental implant survival : a 4-year retrospective analysis", J Periodontol, 82, pp.1390~1395 (2011)
- Smith RA, "Risk factors associated with dental implants in healthy and medically compromised patients", Int J Oral Maxillofac Implants, 7, pp.367~372 (1992)
- Kang DY, "Early implant failure : a retrospective analysis of contributing factors", J Periodontal Implant Sci, 49, pp.287~298 (2019)
- Park YS, "Evaluation of failed implants and reimplantation at sites of previous dental implant failure : survival rates and risk factors", J Periodontal Implant Sci, 52, pp.230~241 (2022)
- Moy PK, "Dental implant failure rates and associated risk factors", Int J Oral Maxillofac Implants, 20, pp.569~577 (2005)
- Schimmel M, "Implants for elderly patients", Periodontol 2000, 73, pp.228~240 (2017)
- el Askary AS, "Why do dental implants fail? Part I", Implant Dent, 8, pp.173~185 (1999)
- Lee KJ, "Influence of crown-to-implant ratio on periimplant marginal bone loss in the posterior region : a five-year retrospective study", J Periodontal Implant Sci, 42, pp.231~236 (2012)
- Kim MJ, "The long-term evaluation of the prognosis of implants with acid-etched surfaces sandblasted with alumina : a retrospective clinical study", Maxillofac Plast Reconstr Surg, 42, pp.10~ (2020)
- Draenert FG, "Retrospective analysis of survival rates and marginal bone loss on short implants in the mandible", Clin Oral Implants Res, 23, pp.1063~1069 (2012)
- Galindo-Moreno P, "Clinical and radiographic evaluation of early loaded narrow diameter implants-1-year follow-up", Clin Oral Implants Res, 23, pp.609~616 (2012)
- Shi JY, "Long-term outcomes of narrow diameter implants in posterior jaws : a retrospective study with at least 8-year follow-up", Clin Oral Implants Res, 29, pp.76~81 (2018)
- Sakka S, "Factors associated with early and late failure of dental implants", J Investig Clin Dent, 3, pp.258~261 (2012)
- el Askary AS, "Why do dental implants fail? Part II", Implant Dent, 8, pp.265~277 (1999)
- Levin L, "The effect of cigarette smoking on dental implants and related surgery", Implant Dent, 14, pp.357~361 (2005)
- Lekholm U, "Tissue integrated prostheses: osseointegration in clinical dentistry", pp.199~220 (1985), Quintessence
- Sakka S, "Bone quality : a reality for the process of osseointegration", Implant Dent, 18, pp.480~485 (2009)