The cumulative survival rate of dental implants with micro-threads: a long-term retrospective study
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose: This study aimed to evaluate the long-term cumulative survival rate (CSR) of dental implants with micro-threads in the neck over a 10-year follow-up period and to examine the factors influencing the survival rate of dental implants. Methods: This retrospective study was based on radiographic and dental records. In total, 151 patients received 490 Oneplant® dental implants with an implant neck micro-thread design during 2006–2010 in the Department of Periodontology of Seoul National University Dental Hospital. Implant survival was evaluated using Kaplan–Meier analysis. Cox proportional hazard regression analysis was used to identify the factors influencing implant failure. Results: Ten out of 490 implants (2.04%) failed due to fixture fracture. The CSR of the implants was 97.9%, and no significant difference was observed in the CSR between externaland internal-implant types (98.2% and 97.6%, respectively, P=0.670). In Cox regression analysis, 2-stage surgery significantly increased the risk of implant failure (hazard ratio: 4.769, P=0.039). There were no significant differences in influencing factors, including sex, age, implant diameter, length, fixture type, location, surgical procedure, bone grafting, and restoration type. Conclusions: Within the limitations of this retrospective study, the micro-thread design of the implant neck was found to be favorable for implant survival, with stable clinical outcomes.
Abstract
Purpose: This study aimed to evaluate the long-term cumulative survival rate (CSR) of dental implants with micro-threads in the neck over a 10-year follow-up period and to examine the factors influencing the survival rate of dental implants. Methods: This retrospective study was based on radiographic and dental records. In total, 151 patients received 490 Oneplant® dental implants with an implant neck micro-thread design during 2006–2010 in the Department of Periodontology of Seoul National University Dental Hospital. Implant survival was evaluated using Kaplan–Meier analysis. Cox proportional hazard regression analysis was used to identify the factors influencing implant failure. Results: Ten out of 490 implants (2.04%) failed due to fixture fracture. The CSR of the implants was 97.9%, and no significant difference was observed in the CSR between externaland internal-implant types (98.2% and 97.6%, respectively, P=0.670). In Cox regression analysis, 2-stage surgery significantly increased the risk of implant failure (hazard ratio: 4.769, P=0.039). There were no significant differences in influencing factors, including sex, age, implant diameter, length, fixture type, location, surgical procedure, bone grafting, and restoration type. Conclusions: Within the limitations of this retrospective study, the micro-thread design of the implant neck was found to be favorable for implant survival, with stable clinical outcomes.
참고문헌 (40)
- Brånemark PI, "Osseointegration and its experimental background", J Prosthet Dent, 50, pp.399~410 (1983)
- Alghamdi HS, "The development and future of dental implants", Dent Mater J, 39, pp.167~172 (2020)
- Cho YD, "Patent landscape report on dental implants : a technical analysis", Clin Implant Dent Relat Res, 23, pp.857~863 (2021)
- Jung RE, "Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years", Clin Oral Implants Res, 23(Suppl 6), pp.2~21 (2012)
- Hjalmarsson L, "A systematic review of survival of single implants as presented in longitudinal studies with a follow-up of at least 10 years", Eur J Oral Implantology, 9(Suppl 1), pp.S155~S162 (2016)
- Jung RE, "A systematic review of the 5-year survival and complication rates of implant-supported single crowns", Clin Oral Implants Res, 19, pp.119~130 (2008)
- Blanco J, "Long-term results and survival rate of implants treated with guided bone regeneration : a 5-year case series prospective study", Clin Oral Implants Res, 16, pp.294~301 (2005)
- Albrektsson T, "The long-term efficacy of currently used dental implants : a review and proposed criteria of success", Int J Oral Maxillofac Implants, 1, pp.11~25 (1986)
- Buser D, "Long-term evaluation of non-submerged ITI implants. Part 1 : 8-year life table analysis of a prospective multi-center study with 2359 implants", Clin Oral Implants Res, 8, pp.161~172 (1997)
- Misch CE, "Implant success, survival, and failure : the International Congress of Oral Implantologists(ICOI)Pisa Consensus Conference", Implant Dent, 17, pp.5~15 (2008)
- Papaspyridakos P, "Success criteria in implant dentistry : a systematic review", J Dent Res, 91, pp.242~248 (2012)
- Wennerberg A, "Effects of titanium surface topography on bone integration : a systematic review", Clin Oral Implants Res, 20(Suppl 4), pp.172~184 (2009)
- Sykaras N, "Implant materials, designs, and surface topographies : their effect on osseointegration. A literature review", Int J Oral Maxillofac Implants, 15, pp.675~690 (2000)
- Abrahamsson I, "Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog", Clin Oral Implants Res, 15, pp.381~392 (2004)
- Botticelli D, "Bone regeneration at implants with turned or rough surfaces in self-contained defects. An experimental study in the dog", J Clin Periodontol, 32, pp.448~455 (2005)
- Steigenga JT, "Dental implant design and its relationship to long-term implant success", Implant Dent, 12, pp.306~317 (2003)
- Lan TH, "Biomechanical analysis of alveolar bone stress around implants with different thread designs and pitches in the mandibular molar area", Clin Oral Investig, 16, pp.363~369 (2012)
- Lee JY, "A 5-year retrospective clinical study of the Dentium implants", J Adv Prosthodont, 3, pp.229~235 (2011)
- Lee DW, "Effect of microthread on the maintenance of marginal bone level : a 3-year prospective study", Clin Oral Implants Res, 18, pp.465~470 (2007)
- Hudieb MI, "Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant", J Periodontol, 82, pp.1061~1070 (2011)
- Greenstein G, "Implant insertion torque : its role in achieving primary stability of restorable dental implants", Compend Contin Educ Dent, 38, pp.88~95 (2017)
- Oh TJ, "The causes of early implant bone loss : myth or science?", J Periodontol, 73, pp.322~333 (2002)
- Guo XE, "Bone mechanics handbook", pp.1~23 (2001), CRC Press
- Song DW, "Comparative analysis of peri-implant marginal bone loss based on microthread location : a 1-year prospective study after loading", J Periodontol, 80, pp.1937~1944 (2009)
- Al-Thobity AM, "Microthreaded implants and crestal bone loss : a systematic review", J Oral Implantol, 43, pp.157~166 (2017)
- Troiano G, "Early and late implant failure of submerged versus non-submerged implant healing : a systematic review, meta-analysis and trial sequential analysis", J Clin Periodontol, 45, pp.613~623 (2018)
- Ikebe K, "Is old age a risk factor for dental implants?", Jpn Dent Sci Rev, 45, pp.59~64 (2009)
- Olmedo-Gaya MV, "Risk factors associated with early implant failure : a 5-year retrospective clinical study", J Prosthet Dent, 115, pp.150~155 (2016)
- Manzano G, "Risk factors in early implant failure : a meta-analysis", Implant Dent, 25, pp.272~280 (2016)
- Wyatt CC, "Treatment outcomes of patients with implant-supported fixed partial prostheses", Int J Oral Maxillofac Implants, 13, pp.204~211 (1998)
- Flores-Guillen J, "Five-year outcomes of a randomized clinical trial comparing bone-level implants with either submerged or transmucosal healing", J Clin Periodontol, 45, pp.125~135 (2018)
- Sanz M, "Clinical and radiologic outcomes after submerged and transmucosal implant placement with two-piece implants in the anterior maxilla and mandible : 3-year results of a randomized controlled clinical trial", Clin Implant Dent Relat Res, 17, pp.234~246 (2015)
- Zitzmann NU, "Long-term results of implants treated with guided bone regeneration : a 5-year prospective study", Int J Oral Maxillofac Implants, 16, pp.355~366 (2001)
- Katsavochristou A, "Incidence of abutment screw failure of single or splinted implant prostheses : a review and update on current clinical status", J Oral Rehabil, 46, pp.776~786 (2019)
- De Bruyn H, "The effect of smoking on early implant failure", Clin Oral Implants Res, 5, pp.260~264 (1994)
- Naseri R, "Levels of smoking and dental implants failure : a systematic review and meta-analysis", J Clin Periodontol, 47, pp.518~528 (2020)
- Hong JY, "Implant survival and risk factor analysis in regenerated bone : results from a 5-year retrospective study", J Periodontal Implant Sci, 50, pp.379~391 (2020)
- Fiorellini JP, "A retrospective study of dental implants in diabetic patients", Int J Periodontics Restorative Dent, 20, pp.366~373 (2000)
- Asvanund P, "Photoelastic stress analysis of external versus internal implant-abutment connections", J Prosthet Dent, 106, pp.266~271 (2011)
- Albrektsson T, "Implant survival and complications. The Third EAO consensus conference 2012", Clin Oral Implants Res, 23(Suppl 6), pp.63~65 (2012)