본문 바로가기
KERD
논문KCI 등재

Core Needle Biopsy Is a More Conclusive Follow-up Method Than Repeat Fine Needle Aspiration for Thyroid Nodules with Initially Inconclusive Results: A Systematic Review and Meta-Analysis

1

조회

0

다운로드

7

인용

0

참고문헌

키워드

주제분류병리학

초록

Background: This study investigated the appropriate management of thyroid nodules with prior non-diagnostic or atypia of undetermined significance/follicular lesion of undetermined significance (AUS/FLUS) through a systematic review and meta-analysis. Methods: This study included 4,235 thyroid nodules from 26 eligible studies. We investigated the conclusive rate of follow-up core needle biopsy (CNB) or repeat fine needle aspiration (rFNA) after initial fine needle aspiration (FNA) with non-diagnostic or AUS/FLUS results. A diagnostic test accuracy (DTA) review was performed to determine the diagnostic role of the follow-up CNB and to calculate the area under the curve (AUC) on the summary receiver operating characteristic (SROC) curve. Results: The conclusive rates of follow-up CNB and rFNA after initial FNA were 0.879 (95% confidence interval [CI], 0.801 to 0.929) and 0.684 (95% CI, 0.627 to 0.736), respectively. In comparison of the odds ratios of CNB and rFNA, CNB had more frequent conclusive results than rFNA (odds ratio, 5.707; 95% CI, 2.530 to 12.875). Upon subgroup analysis, follow-up CNB showed a higher conclusive rate than rFNA in both initial non-diagnostic and AUS/FLUS subgroups. In DTA review of follow-up CNB, the pooled sensitivity and specificity were 0.94 (95% CI, 0.88 to 0.97) and 0.88 (95% CI, 0.84 to 0.91), respectively. The AUC for the SROC curve was 0.981, nearing 1. Conclusions: Our results show that CNB has a higher conclusive rate than rFNA when the initial FNA produced inconclusive results. Further prospective studies with more detailed criteria are necessary before follow-up CNB can be applied in daily practice.

Abstract

Background: This study investigated the appropriate management of thyroid nodules with prior non-diagnostic or atypia of undetermined significance/follicular lesion of undetermined significance (AUS/FLUS) through a systematic review and meta-analysis. Methods: This study included 4,235 thyroid nodules from 26 eligible studies. We investigated the conclusive rate of follow-up core needle biopsy (CNB) or repeat fine needle aspiration (rFNA) after initial fine needle aspiration (FNA) with non-diagnostic or AUS/FLUS results. A diagnostic test accuracy (DTA) review was performed to determine the diagnostic role of the follow-up CNB and to calculate the area under the curve (AUC) on the summary receiver operating characteristic (SROC) curve. Results: The conclusive rates of follow-up CNB and rFNA after initial FNA were 0.879 (95% confidence interval [CI], 0.801 to 0.929) and 0.684 (95% CI, 0.627 to 0.736), respectively. In comparison of the odds ratios of CNB and rFNA, CNB had more frequent conclusive results than rFNA (odds ratio, 5.707; 95% CI, 2.530 to 12.875). Upon subgroup analysis, follow-up CNB showed a higher conclusive rate than rFNA in both initial non-diagnostic and AUS/FLUS subgroups. In DTA review of follow-up CNB, the pooled sensitivity and specificity were 0.94 (95% CI, 0.88 to 0.97) and 0.88 (95% CI, 0.84 to 0.91), respectively. The AUC for the SROC curve was 0.981, nearing 1. Conclusions: Our results show that CNB has a higher conclusive rate than rFNA when the initial FNA produced inconclusive results. Further prospective studies with more detailed criteria are necessary before follow-up CNB can be applied in daily practice.

참고문헌 (49)

  1. Sprague BL, "Thyroid cancer incidence and socioeconomic indicators of health care access", Cancer Causes Control, 19, pp.585~593 (2008)
  2. Enewold L, "Rising thyroid cancer incidence in the United States by demographic and tumor characteristics, 1980-2005", Cancer Epidemiol Biomarkers Prev, 18, pp.784~791 (2009)
  3. Mercante G, "Prognostic factors affecting neck lymph node recurrence and distant metastasis in papillary microcarcinoma of the thyroid: results of a study in 445 patients", Thyroid, 19, pp.707~716 (2009)
  4. Cibas ES, "The Bethesda System for Reporting Thyroid Cytopathology", Thyroid, 19, pp.1159~1165 (2009)
  5. American Thyroid Association (ATA) Guidelines Taskforce on Thyroid Nodules and Differentiated Thyroid Cancer, "Revised American Thyroid Association management guidelines for patients with thyroid nodules and differentiated thyroid cancer", Thyroid, 19, pp.1167~1214 (2009)
  6. Gharib H, "American Association of Clinical Endocrinologists, Associazione Medici Endocrinologi, and European Thyroid Association medical guidelines for clinical practice for the diagnosis and management of thyroid nodules: executive summary of recommendations", J Endocrinol Invest, 33(5 suppl 1), pp.51~56 (2010)
  7. Yang J, "Fine-needle aspiration of thyroid nodules: a study of 4703 patients with histologic and clinical correlations", Cancer, 111, pp.306~315 (2007)
  8. Yassa L, "Long-term assessment of a multidisciplinary approach to thyroid nodule diagnostic evaluation", Cancer, 111, pp.508~516 (2007)
  9. Nayar R, "The indeterminate thyroid fine-needle aspiration:experience from an academic center using terminology similar to that proposed in the 2007 National Cancer Institute Thyroid Fine Needle Aspiration State of the Science Conference", Cancer, 117, pp.195~202 (2009)
  10. Harvey JN, "Sonographically guided core biopsy in the assessment of thyroid nodules", J Clin Ultrasound, 33, pp.57~62 (2005)
  11. Renshaw AA, "Comparison of thyroid fine-needle aspiration and core needle biopsy", Am J Clin Pathol, 128, pp.370~374 (2007)
  12. Zamora J, "Meta-DiSc: a software for meta-analysis of test accuracy data", BMC Med Res Methodol, 6, pp.31~ (2006)
  13. Pyo JS, "BRAF immunohistochemistry using clone VE1 is strongly soncordant with BRAF(V600E) mutation test in papillary thyroid carcinoma", Endocr Pathol, 26, pp.211~217 (2015)
  14. Anderson TJ, "Management of nodules with initially nondiagnostic results of thyroid fine-needle aspiration: can we avoid repeat biopsy?", Radiology, 272, pp.777~784 (2014)
  15. Baloch Z, "Role of repeat fine-needle aspiration biopsy (FNAB) in the management of thyroid nodules", Diagn Cytopathol, 29, pp.203~206 (2003)
  16. Chen JC, "Yield of repeat fine-needle aspiration biopsy and rate of malignancy in patients with atypia or follicular lesion of undetermined significance:the impact of the Bethesda System for Reporting Thyroid Cytopathology", Surgery, 152, pp.1037~1044 (2012)
  17. Choi YJ, "Differences in risk of malignancy and management recommendations in subcategories of thyroid nodules with atypia of undetermined significance or follicular lesion of undetermined significance: the role of ultrasound-guided core-needle biopsy", Thyroid, 24, pp.494~501 (2014)
  18. Choi SH, "Thyroid nodules with initially nondiagnostic, fine-needle aspiration results: comparison of core-needle biopsy and repeated fine-needle aspiration", Eur Radiol, 24, pp.2819~2826 (2014)
  19. Dincer N, "Follow-up of atypia and follicular lesions of undetermined significance in thyroid fine needle aspiration cytology", Cytopathology, 24, pp.385~390 (2013)
  20. Gocun PU, "What is the malignancy risk for atypia of undetermined significance? Three years’ experience at a university hospital in Turkey", Cancer Cytopathol, 122, pp.604~610 (2014)
  21. Gweon HM, "Thyroid nodules with Bethesda system III cytology: can ultrasonography guide the next step?", Ann Surg Oncol, 20, pp.3083~3088 (2013)
  22. Ho AS, "Malignancy rate in thyroid nodules classified as Bethesda category III (AUS", FLUS), 2014, pp.24, 832~839
  23. Hyeon J, "The prediction of malignant risk in the category “atypia of undetermined significance", follicular lesion of undetermined significance” of the Bethesda System for Reporting Thyroid Cytopathology using subcategorization and BRAF mutation results, 2014, pp.122, 368~376
  24. Jo VY, "Repeatedly nondiagnostic thyroid fine-needle aspirations do not modify malignancy risk", Acta Cytol, 55, pp.539~543 (2011)
  25. Lee SH, "Identification of plant compounds that disrupt the insect juvenile hormone receptor complex", Proc Natl Acad Sci U S A, 112, pp.1733~1738 (2015)
  26. Lee SH, "Clinical outcomes in patients with non-diagnostic thyroid fine needle aspiration cytology: usefulness of the thyroid core needle biopsy", Ann Surg Oncol, 21, pp.1870~1877 (2014)
  27. Moon HJ, "Malignancy risk stratification in thyroid nodules with nondiagnostic results at cytologic examination:combination of thyroid imaging reporting and data system and the Bethesda System", Radiology, 274, pp.287~295 (2015)
  28. Moslavac S, "When to repeat thyroid fine needle aspiration cytology?", Acta Clin Croat, 51, pp.549~554 (2012)
  29. Na DG, "Role of core needle biopsy in the management of atypia", follicular lesion of undetermined significance thyroid nodules: comparison with repeat fine-needle aspiration in subcategory nodules, 2015, pp.4, 189~196
  30. Na DG, "Core-needle biopsy is more useful than repeat fine-needle aspiration in thyroid nodules read as nondiagnostic or atypia of undetermined significance by the Bethesda system for reporting thyroid cytopathology", Thyroid, 22, pp.468~475 (2012)
  31. Nagarkatti SS, "Management of thyroid nodules with atypical cytology on fine-needle aspiration biopsy", Ann Surg Oncol, 20, pp.60~65 (2013)
  32. Oertel YC, "Value of repeated fine needle aspirations of the thyroid: an analysis of over ten thousand FNAs", Thyroid, 17, pp.1061~1066 (2007)
  33. Park KT, "Role of core needle biopsy and ultrasonographic finding in management of indeterminate thyroid nodules", Head Neck, 33, pp.160~165 (2011)
  34. Park VY, "Malignancy risk and characteristics of thyroid nodules with two consecutive results of atypia of undetermined significance or follicular lesion of undetermined significance on cytology", Eur Radiol, 25, pp.2601~2607 (2015)
  35. Samir AE, "Ultrasound-guided percutaneous thyroid nodule core biopsy: clinical utility in patients with prior nondiagnostic fine-needle aspirate", Thyroid, 22, pp.461~467 (2012)
  36. Sullivan PS, "The impact of atypia", follicular lesion of undetermined significance and repeat fine-needle aspiration: 5 years before and after implementation of the Bethesda System, 2014, pp.122, 866~872
  37. Trimboli P, "A cost analysis of thyroid core needle biopsy vs. diagnostic surgery", Gland Surg, 4, pp.307~311 (2015)
  38. Yeon JS, "Thyroid nodules with initially nondiagnostic cytologic results: the role of core-needle biopsy", Radiology, 268, pp.274~280 (2013)
  39. Yoon JH, "Inadequate cytology in thyroid nodules: should we repeat aspiration or follow-up?", Surg Oncol, 18, pp.1282~1289 (2011)
  40. Degirmenci B, "Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material", Clin Radiol, 62, pp.798~803 (2007)
  41. Choi YS, "Clinical and ultrasonographic findings affecting nondiagnostic results upon the second fine needle aspiration for thyroid nodules", Ann Surg Oncol, 19, pp.2304~2309 (2012)
  42. Choi SH, "Factors affecting inadequate sampling of ultrasound-guided fine-needle aspiration biopsy of thyroid nodules", Clin Endocrinol (Oxf), 74, pp.776~782 (2011)
  43. Moon HJ, "Ultrasonographic character istics predictive of nondiagnostic results for fine-needle aspiration biopsies of thyroid nodules", Ultrasound Med Biol, 37, pp.549~555 (2011)
  44. Orija IB, "Value of repeating a nondiagnostic thyroid fine-needle aspiration biopsy", Endocr Pract, 13, pp.735~742 (2007)
  45. Hryhorczuk AL, "Prevalence of malignancy in thyroid nodules with an initial nondiagnostic result after ultrasound guided fine needle aspiration", Ultrasound Med Biol, 38, pp.561~567 (2012)
  46. Lubitz CC, "Diagnostic yield of nondiagnostic thyroid nodules is not altered by timing of repeat biopsy", Thyroid, 22, pp.590~594 (2012)
  47. Li L, "Comparison of pre-operation diagnosis of thyroid cancer with fine needle aspiration and core-needle biopsy:a meta-analysis", Asian Pac J Cancer Prev, 15, pp.7187~7193 (2014)
  48. 윤정현, "Effectiveness and Limitations of Core Needle Biopsy in the Diagnosis of Thyroid Nodules: Review of Current Literature", Journal of Pathology and Translational Medicine, 49(3), pp.230~235 (2015), 대한병리학회[DOI]
  49. Novoa E, "Role of ultrasound-guided core-needle biopsy in the assessment of head and neck lesions:a meta-analysis and systematic review of the literature", Head Neck, 34, pp.1497~1503 (2012)

관련 논문AI추천

Usage and Diagnostic Yield of Fine-Needle Aspiration Cytology and Core Needle Biopsy in Thyroid Nodules: A Systematic Review and Meta-Analysis of Literature Published by Korean Authors안순현대한이비인후과학회 · Clinical and Experimental Otorhinolaryngology2021 · 제14권 제1호Effectiveness and Limitations of Core Needle Biopsy in the Diagnosis of Thyroid Nodules: Review of Current Literature곽진영, 김은경, 문희정, 윤정현대한병리학회 · Journal of Pathology and Translational Medicine2015 · 제49권 제3호Core-Needle Biopsy Does Not Show Superior Diagnostic Performance to Fine-Needle Aspiration for Diagnosing Thyroid Nodules곽진영, 김은경, 문희정, 박영진, 신일아, 윤정현, 이시은, 이혜선연세대학교의과대학 · Yonsei Medical Journal2020 · 제61권 제2호Diagnostic yield of fine needle aspiration with simultaneous core needle biopsy for thyroid nodulesAlireza Mohamadian, Amir Aria, Elham Nazar, Hoda Asefi, Hojat Ebrahiminik, Mohammad Ali Hasannia, Ramin Pourghorban대한병리학회 · Journal of Pathology and Translational Medicine2025 · 제59권 제3호세침흡인생검에서 비진단결과를 보인 갑상선결절에서 중심부바늘생검의 역할백정환대한갑상선학회 · International Journal of Thyroidology2016 · 제9권 제1호Reevaluating diagnostic categories and associated malignancy risks in thyroid core needle biopsy정찬권대한병리학회 · Journal of Pathology and Translational Medicine2023 · 제57권 제4호

이 간행물의 다른 논문 (11건)