Usage and Diagnostic Yield of Fine-Needle Aspiration Cytology and Core Needle Biopsy in Thyroid Nodules: A Systematic Review and Meta-Analysis of Literature Published by Korean Authors
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Objectives. The usefulness of core needle biopsy (CNB) for the diagnosis of thyroid nodules remains controversial, and preferences vary across hospitals. The purpose of this study was to assess the actual use of CNB in Korea and to analyze the advantages and disadvantages of CNB through a systematic review and meta-analysis of papers published by Korean authors. Methods. A meta-analysis of full-text publications published in English presenting data from Korea retrieved from the Embase literature database was performed. Results. CNB led to a significantly lower proportion of non-diagnostic results than fine-needle aspiration (FNA). However, the frequency of atypia of undetermined significance/follicular lesion of undetermined significance (AUS/FLUS) did not decrease as a result of performing CNB in nodules with initial AUS/FLUS results, while it increased in consecutive cases. A subcategory analysis of AUS/FLUS showed that the increased frequency of AUS/FLUS findings on CNB was due to more frequent diagnoses of architectural atypia and follicular neoplasm, which resulted in a higher frequency of inconclusive findings in consecutive cases compared to FNA. Hospitals favoring CNB had a higher proportion of AUS/FLUS diagnoses. Although the complication rate did not differ significantly between CNB and FNA, serious complications of CNB did occur. Conclusion. A reduced frequency of non-diagnostic results may be a definite advantage of CNB over FNA. However, the increased frequency of diagnoses of architectural atypia and follicular neoplasm should be considered when selecting CNB as a diagnostic tool.
Abstract
Objectives. The usefulness of core needle biopsy (CNB) for the diagnosis of thyroid nodules remains controversial, and preferences vary across hospitals. The purpose of this study was to assess the actual use of CNB in Korea and to analyze the advantages and disadvantages of CNB through a systematic review and meta-analysis of papers published by Korean authors. Methods. A meta-analysis of full-text publications published in English presenting data from Korea retrieved from the Embase literature database was performed. Results. CNB led to a significantly lower proportion of non-diagnostic results than fine-needle aspiration (FNA). However, the frequency of atypia of undetermined significance/follicular lesion of undetermined significance (AUS/FLUS) did not decrease as a result of performing CNB in nodules with initial AUS/FLUS results, while it increased in consecutive cases. A subcategory analysis of AUS/FLUS showed that the increased frequency of AUS/FLUS findings on CNB was due to more frequent diagnoses of architectural atypia and follicular neoplasm, which resulted in a higher frequency of inconclusive findings in consecutive cases compared to FNA. Hospitals favoring CNB had a higher proportion of AUS/FLUS diagnoses. Although the complication rate did not differ significantly between CNB and FNA, serious complications of CNB did occur. Conclusion. A reduced frequency of non-diagnostic results may be a definite advantage of CNB over FNA. However, the increased frequency of diagnoses of architectural atypia and follicular neoplasm should be considered when selecting CNB as a diagnostic tool.
참고문헌 (72)
- Park KT, "Role of core needle biopsy and ultrasonographic finding in management of indeterminate thyroid nodules", Head Neck, 33(2), pp.160~165 (2011)
- Cao H, "Comparison of core-needle biopsy and fine-needle aspiration in screening for thyroid malignancy: a systematic review and meta-analysis", Curr Med Res Opin, 32(7), pp.1291~1301 (2016)
- Chung SR, "The role of core needle biopsy in the diagnosis of initially detected thyroid nodules: a systematic review and meta-analysis", Eur Radiol, 28(11), pp.4909~4918 (2018)
- Li L, "Comparison of pre-operation diagnosis of thyroid cancer with fine needle aspiration and core-needle biopsy: a meta-analysis", Asian Pac J Cancer Prev, 15(17), pp.7187~7193 (2014)
- Liu N, "Ultrasound-guided core needle biopsy for differential diagnosis of thyroid nodules: a systematic review and meta-analysis", Mol Clin Oncol, 6(6), pp.825~832 (2017)
- 표정수, "Core Needle Biopsy Is a More Conclusive Follow-up Method Than Repeat Fine Needle Aspiration for Thyroid Nodules with Initially Inconclusive Results: A Systematic Review and Meta-Analysis", Journal of Pathology and Translational Medicine, 50(3), pp.217~224 (2016), 대한병리학회[DOI]
- Suh CH, "The role of core-needle biopsy for thyroid nodules with initially nondiagnostic fine-needle aspiration results: a systematic review and meta-analysis", Endocr Pract, 22(6), pp.679~688 (2016)
- Suh CH, "The role of core-needle biopsy in the diagnosis of thyroid malignancy in 4580patients with 4746 thyroid nodules: a systematic review and metaanalysis", Endocrine, 54(2), pp.315~328 (2016)
- Suh CH, "The role of core needle biopsy for thyroid nodules with initially indeterminate results on previous fine-needle aspiration: a systematic review and meta-analysis", AJNR Am J Neuroradiol, 38(7), pp.1421~1426 (2017)
- Pierpaolo Trimboli, "Reliability of core needle biopsy as a second-line procedure in thyroid nodules with an indeterminate fine-needle aspiration report: a systematic review and meta-analysis", ULTRASONOGRAPHY, 37(2), pp.121~128 (2018), 대한초음파의학회
- Wolinski K, "Comparison of diagnostic yield of core-needle and fine-needle aspiration biopsies of thyroid lesions: systematic review and meta-analysis", Eur Radiol, 27(1), pp.431~436 (2017)
- 정찬권, "Pathology Reporting of Thyroid Core Needle Biopsy: A Proposal of the Korean Endocrine Pathology Thyroid Core Needle Biopsy Study Group", Journal of Pathology and Translational Medicine, 49(4), pp.288~299 (2015), 대한병리학회[DOI]
- Choi SH, "Thyroid nodules with initially non-diagnostic, fine-needle aspiration results: comparison of core-needle biopsy and repeated fine-needle aspiration", Eur Radiol, 24(11), pp.2819~2826 (2014)
- Choi YJ, "Coreneedle biopsy versus repeat fine-needle aspiration for thyroid nodules initially read as atypia", follicular lesion of undetermined significance, 2017, pp.39(2), 361~369
- Hong SH, "Malignancy risk and related factors of atypia of undetermined significance", follicular lesion of undetermined significance in thyroid fine needle aspiration, 2018, pp.2018, 4521984~
- Lee SH, "Clinical outcomes in patients with non-diagnostic thyroid fine needle aspiration cytology: usefulness of the thyroid core needle biopsy", Ann Surg Oncol, 21(6), pp.1870~1877 (2014)
- Na DG, "Coreneedle biopsy is more useful than repeat fine-needle aspiration in thyroid nodules read as nondiagnostic or atypia of undetermined significance by the Bethesda system for reporting thyroid cytopathology", Thyroid, 22(5), pp.468~475 (2012)
- Na DG, "Role of core needle biopsy in the management of atypia", follicular lesion of undetermined significance thyroid nodules: comparison with repeat fine-needle aspiration in subcategory nodules, 2015, pp.4(3), 189~196
- Park VY, "Malignancy risk and characteristics of thyroid nodules with two consecutive results of atypia of undetermined significance or follicular lesion of undetermined significance on cytology", Eur Radiol, 25(9), pp.2601~2607 (2015)
- Yeon JS, "Thyroid nodules with initially nondiagnostic cytologic results: the role of core-needle biopsy", Radiology, 268(1), pp.274~280 (2013)
- Yoon JH, "Non-diagnostic thyroid nodules after application of the Bethesda system: a study evaluating the interval for repeat aspiration for non-diagnostic results", Acta Radiol, 59(3), pp.305~312 (2018)
- Yoon JH, "Ultrasonography-guided core needle biopsy did not reduce diagnostic lobectomy for thyroid nodules diagnosed as atypia of undetermined significance", follicular lesion of undetermined significance, 2019, pp.35(3), 253~258
- Ahn HS, "Comparison of the diagnostic efficacy of ultrasound-guided core needle biopsy with 18- versus 20-gauge needles for thyroid nodules", J Ultrasound Med, 37(11), pp.2565~2574 (2018)
- Ahn SH, "Comparison of consecutive results from fine needle aspiration and core needle biopsy in thyroid nodules", Endocr Pathol, 28(4), pp.332~338 (2017)
- Chang H, "Comparison of diagnostic values of thyroid aspiration samples using liquid-based preparation and conventional smear: one-year experience in a single institution", APMIS, 121(2), pp.139~145 (2013)
- Choe J, "Core needle biopsy of thyroid nodules: outcomes and safety from a large single-center single-operator study", Acta Radiol, 59(8), pp.924~931 (2018)
- Choe JY, "Utility of a formatted pathologic reporting system in thyroid core needle biopsy: a validation study of 1998 consecutive cases", Clin Endocrinol (Oxf), 88(1), pp.96~104 (2018)
- Choi SH, "Factors affecting inadequate sampling of ultrasound-guided fine-needle aspiration biopsy of thyroid nodules", Clin Endocrinol (Oxf), 74(6), pp.776~782 (2011)
- Chong Y, "Comparison of EASYPREP(R) and SurePath(R) in thyroid fine-needle aspiration", Diagn Cytopathol, 44(4), pp.283~290 (2016)
- Chung SR, "Risk of malignancy according to the sub-classification of atypia of undetermined significance and suspicious follicular neoplasm categories in thyroid core needle biopsies", Endocr Pathol, 30(2), pp.146~154 (2019)
- Chung SR, "Ultrasound-pathology discordant nodules on core-needle biopsy: malignancy risk and management strategy", Thyroid, 27(5), pp.707~713 (2017)
- Hong MJ, "Cytology-ultrasonography risk-stratification scoring system based on fine-needle aspiration cytology and the Korean-Thyroid Imaging Reporting and Data System", Thyroid, 27(7), pp.953~959 (2017)
- 홍민지, "Role of core needle biopsy as a first-line diagnostic tool for thyroid nodules: a retrospective cohort study", ULTRASONOGRAPHY, 37(3), pp.244~253 (2018), 대한초음파의학회
- Hyeon J, "The prediction of malignant risk in the category “atypia of undetermined significance", follicular lesion of undetermined significance” of the Bethesda System for Reporting Thyroid Cytopathology using subcategorization and BRAF mutation results, 2014, pp.122(5), 368~376
- Jung CK, "Split sample comparison of a liquid-based method and conventional smears in thyroid fine needle aspiration", Acta Cytol, 52(3), pp.313~319 (2008)
- Jung SJ, "Comparison study of the adequacy and pain scale of ultrasound-guided fine-needle aspiration of solid thyroid nodules with a 21- or 23-gauge needle for liquid-based cytology: a single-center study", Endocr Pathol, 29(1), pp.30~34 (2018)
- Kim DL, "High prevalence of carcinoma in ultrasonography-guided fine needle aspiration cytology of thyroid nodules", Endocr J, 55(1), pp.135~142 (2008)
- Kim DW, "Ultrasonography-guided fine-needle aspiration cytology for thyroid nodules: an emphasis on one-sampling and biopsy techniques", Diagn Cytopathol, 40(Suppl 1), pp.E48~E54 (2012)
- Kim DW, "Ultrasound-guided fine-needle aspiration biopsy of thyroid nodules: comparison in efficacy according to nodule size", Thyroid, 19(1), pp.27~31 (2009)
- 김지훈, "Ultrasonographic Echogenicity and Histopathologic Correlation of Thyroid Nodules in Core Needle Biopsy Specimens", Korean Journal of Radiology, 19(4), pp.673~681 (2018), 대한영상의학회[DOI]
- 김미림, "Cytologic Diagnosis of Noninvasive Follicular Thyroid Neoplasm with Papillary-like Nuclear Features and Its Impact on the Risk of Malignancy in the Bethesda System for Reporting Thyroid Cytopathology: An Institutional Experience", Journal of Pathology and Translational Medicine, 52(3), pp.171~178 (2018), 대한병리학회[DOI]
- Kim SY, "Combined use of conventional smear and liquid-based preparation versus conventional smear for thyroid fine-needle aspiration", Endocrine, 53(1), pp.157~165 (2016)
- Kim YH, "Applying ultrasound-guided core needle biopsy for diagnosis of thyroid masses: preliminary results from a single institution", J Ultrasound Med, 34(10), pp.1801~1808 (2015)
- Koh J, "The 5-tiered categorization system for reporting cytology is sufficient for management of patients with thyroid nodules compared to the 6-tiered Bethesda system", Endocrine, 53(2), pp.489~496 (2016)
- Mi-Jung Lee, "Cytological Results of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules: Emphasis on Correlation with Sonographic Findings", Yonsei Medical Journal, 52(5), pp.838~844 (2011), 연세대학교의과대학
- Lee YB, "Current status and diagnostic values of the Bethesda system for reporting thyroid cytopathology in a papillary thyroid carcinoma-prevalent area", Head Neck, 39(2), pp.269~274 (2017)
- Moon HJ, "Malignancy risk stratification in thyroid nodules with benign results on cytology: combination of thyroid imaging reporting and data system and Bethesda system", Ann Surg Oncol, 21(6), pp.1898~1903 (2014)
- Moon WJ, "The value of gross visual assessment of specimen adequacy for liquid-based cytology during ultrasound-guided, fine-needle aspiration of thyroid nodules", Endocr Pract, 21(11), pp.1219~1226 (2015)
- Nam-Goong IS, "Ultrasonography-guided fine-needle aspiration of thyroid incidentaloma: correlation with pathological findings", Clin Endocrinol (Oxf), 60(1), pp.21~28 (2004)
- Park SY, "The diagnostic performance of thyroid US in each category of the Bethesda system for reporting thyroid cytopathology", PLoS One, 11(6), pp.e0155898~ (2016)
- Park VY, "Frequencies and malignancy rates of 6-tiered Bethesda categories of thyroid nodules according to ultrasound assessment and nodule size", Head Neck, 40(9), pp.1947~1954 (2018)
- Seok JY, "Improvement of diagnostic performance of pathologists by reducing the number of pathologists responsible for thyroid fine needle aspiration cytology: an institutional experience", Diagn Cytopathol, 46(7), pp.561~567 (2018)
- Song JY, "Reclassifying formerly indeterminate thyroid FNAs using the Bethesda system reduces the number of inconclusive cases", Acta Cytol, 56(2), pp.122~129 (2012)
- Suh CH, "Efficacy and safety of core-needle biopsy in initially detected thyroid nodules via propensity score analysis", Sci Rep, 7(1), pp.8242~ (2017)
- Suh CH, "The role of core-needle biopsy as a first-line diagnostic tool for initially detected thyroid nodules", Thyroid, 26(3), pp.395~403 (2016)
- Sung JY, "Diagnostic accuracy of fine-needle aspiration versus core-needle biopsy for the diagnosis of thyroid malignancy in a clinical cohort", Eur Radiol, 22(7), pp.1564~1572 (2012)
- Yoo RE, "Prediction of nondiagnostic results in fine-needle aspiration of thyroid nodules:utility of on-site gross visual assessment of specimens for liquid-based cytology", Endocr Pract, 24(10), pp.867~874 (2018)
- Chae IH, "Ultrasoundguided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors", Endocrine, 57(1), pp.108~114 (2017)
- Kim SY, "Fine-needle aspiration versus core needle biopsy for diagnosis of thyroid malignancy and neoplasm: a matched cohort study", Eur Radiol, 27(2), pp.801~811 (2017)
- Lee YJ, "Factors that influence sample adequacy in liquid-based cytology after ultrasonography-guided fine-needle aspiration of thyroid nodules: a single-center study", Acta Cytol, 62(4), pp.253~258 (2018)
- Kim SD, "Differences in Clinical features between subcategories of “atypia", follicular lesion of undetermined significance”, 2017, pp.28(3), 247~252
- Kim SJ, "Risk of malignancy according to sub-classification of the atypia of undetermined significance or follicular lesion of undetermined significance (AUS", FLUS) category in the Bethesda system for reporting thyroid cytopathology, 2017, pp.28(1), 65~73
- Park HJ, "Thyroid “atypia of undetermined significance” with nuclear atypia has high rates of malignancy and BRAF mutation", Cancer Cytopathol, 122(7), pp.512~520 (2014)
- Yoon JH, "Subcategorization of atypia of undetermined significance", follicular lesion of undetermined significance (AUS, Clin Endocrinol (Oxf), pp.2016, 85(2)[DOI]
- Yoon RG, "Diagnosis of thyroid follicular neoplasm: fine-needle aspiration versus core-needle biopsy", Thyroid, 24(11), pp.1612~1617 (2014)
- Ha EJ, "Complications following US-guided core-needle biopsy for thyroid lesions: a retrospective study of 6,169 consecutive patients with 6,687 thyroid nodules", Eur Radiol, 27(3), pp.1186~1194 (2017)
- 정은지, "A Comparison of Ultrasound-Guided Fine Needle Aspiration versus Core Needle Biopsy for Thyroid Nodules: Pain, Tolerability, and Complications", Endocrinology and Metabolism, 33(1), pp.114~120 (2018), 대한내분비학회
- Kim HJ, "Thyroid core needle biopsy: patients’ pain and satisfaction compared to fine needle aspiration", Endocrine, 65(2), pp.365~370 (2019)
- Haugen BR, "2015 American Thyroid Association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the American Thyroid Association Guidelines Task Force on Thyroid Nodules and Differentiated Thyroid Cancer", Thyroid, 26(1), pp.1~133 (2016)
- Cibas ES, "The Bethesda system for reporting thyroid cytopathology", Am J Clin Pathol, 132(5), pp.658~665 (2009)
- Ahn SH, "Comparison of risk of malignancy in a subgroup with atypia of undetermined significance", follicular lesion of undetermined significance: a meta-analysis, 2017, pp.39(8), 1699~1710
- Johnson DN, "A proposal for separation of nuclear atypia and architectural atypia in Bethesda category III (AUS", FLUS) based on differing rates of thyroid malignancy, 2019, pp.151(1), 86~94
