본문 바로가기
KERD
논문KCI 등재

광학추적항법장치를 이용한 르포씨 제1형 골절단 가상 수술의 정확성에 대한 연구

Accuracy of simulation surgery of Le Fort I osteotomy using optoelectronic tracking navigation system

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Introduction: The aim of this study was to demonstrate that the simulation surgery on rapid prototype (RP) model, which is based on the 3-dimensional computed tomography (3D CT) data taken before surgery, has the same accuracy as traditional orthograthic surgery with an intermediate splint,using an optoelectronic tracking navigation system. Materials and Methods: Simulation surgery with the same treatment plan as the Le Fort I osteotomy on the patient was done on a RP model based on the 3D CT data of 12 patients who had undergone a Le Fort I osteotomy in the department of oral and maxillofacial surgery, Seoul National University Dental Hospital. The 12 distances between 4 points on the skull, such as both infraorbital foramen and both supraorbital foramen, and 3points on maxilla, such as the contact point of both maxillary central incisors and mesiobuccal cuspal tip of both maxillary first molars, were tracked using an optoelectronic tracking navigation system. The distances before surgery were compared to evaluate the accuracy of the RP model and the distance changes of 3D CT image after surgery were compared with those of the RP model after simulation surgery. Results: A paired t-test revealed a significant difference between the distances in the 3D CT image and RP model before surgery.(P<0.0001) On the other hand, Pearson's correlation coefficient, 0.995, revealed a significant positive correlation between the distances.(P<0.0001) There was a significant difference between the change in the distance of the 3D CT image and RP model in before and after surgery.(P<0.05) The Pearson's correlation coefficient was 0.13844, indicating positive correlation.(P<0.1)Conclusion: Theses results suggest that the simulation surgery of a Le Fort I osteotomy using an optoelectronic tracking navigation system is relatively accurate in comparing the pre-, and post-operative 3D CT data. Furthermore, the application of an optoelectronic tracking navigation system may be a predictable and efficient method in Le Fort I orthognathic surgery.

Abstract

Introduction: The aim of this study was to demonstrate that the simulation surgery on rapid prototype (RP) model, which is based on the 3-dimensional computed tomography (3D CT) data taken before surgery, has the same accuracy as traditional orthograthic surgery with an intermediate splint,using an optoelectronic tracking navigation system. Materials and Methods: Simulation surgery with the same treatment plan as the Le Fort I osteotomy on the patient was done on a RP model based on the 3D CT data of 12 patients who had undergone a Le Fort I osteotomy in the department of oral and maxillofacial surgery, Seoul National University Dental Hospital. The 12 distances between 4 points on the skull, such as both infraorbital foramen and both supraorbital foramen, and 3points on maxilla, such as the contact point of both maxillary central incisors and mesiobuccal cuspal tip of both maxillary first molars, were tracked using an optoelectronic tracking navigation system. The distances before surgery were compared to evaluate the accuracy of the RP model and the distance changes of 3D CT image after surgery were compared with those of the RP model after simulation surgery. Results: A paired t-test revealed a significant difference between the distances in the 3D CT image and RP model before surgery.(P<0.0001) On the other hand, Pearson's correlation coefficient, 0.995, revealed a significant positive correlation between the distances.(P<0.0001) There was a significant difference between the change in the distance of the 3D CT image and RP model in before and after surgery.(P<0.05) The Pearson's correlation coefficient was 0.13844, indicating positive correlation.(P<0.1)Conclusion: Theses results suggest that the simulation surgery of a Le Fort I osteotomy using an optoelectronic tracking navigation system is relatively accurate in comparing the pre-, and post-operative 3D CT data. Furthermore, the application of an optoelectronic tracking navigation system may be a predictable and efficient method in Le Fort I orthognathic surgery.

참고문헌 (16)

  1. Ewers R, "Basic research and 12 years of clinical experience in computer-assisted navigation technology: a review", Int J Oral Maxillofac Surg, 34, pp.1~8 (2005)
  2. Klug C, "Point-to-point computer-assisted navigation for precise transfer of planned zygoma osteotomies from the stereolithographic model into reality", J Oral Maxillofac Surg, 64, pp.550~559 (2006)
  3. Ellis E, 3rd, "Accuracy of model surgery: evaluation of an old technique and introduction of a new one", J Oral Maxillofac Surg, 48, pp.1161~1167 (1990)
  4. Nizam A, "Dimensional Accuracy of the Skull Models Produced by Rapid Prototyping Technology Using Stereolithography Apparatus", Archives of Orofacial Sciences, 1, pp.60~66 (2006)
  5. 김남국, "Analysis of errors in medical rapid prototyping models", INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 31, pp.23~32 (2002), CHURCHILL LIVINGSTONE
  6. Hassfeld S, "ntraoperative navigation in oral and maxillofacial surgery", Int J Oral Maxillofac Surg, 24, pp.111~119 (1995)
  7. Hassfeld S, "Computer assisted oral and maxillofacial surgery-a review and an assessment of technology", Int J Oral Maxillofac Surg, 30, pp.2~13 (2001)
  8. Wagner A, "Imageguided surgery", nt J Oral Maxillofac Surg, 25, pp.147~151 (1996)
  9. Wagner A, "Virtual image guided navigation in tumor surgery-technical innovation", J Craniomaxillofac Surg, 23, pp.271~273 (1995)
  10. Wagner A, "Virtual reality for orthognathic surgery: The augmented reality environment concept", J Oral Maxillofac Surg, 55, pp.456~ (1997)
  11. Watzinger F, "Placement of endosteal implants in the zygoma after maxillectomy: a Cadaver study using surgical navigation", Plast Reconstr Surg, 107, pp.659~667 (2001)
  12. Ewers R, "Seven years of clinical experience with teleconsultation in craniomaxillofacial surgery", J Oral Maxillofac Surg, 63, pp.1447~1454 (2005)
  13. Wagner A, "Clinical experience with interactive teleconsultation and teleassistance in craniomaxillofacial surgical procedures", J Oral Maxillofac Surg, 57, pp.1413~1418 (1999)
  14. Eliashar R, "Image of guided navigation system-a new technology for complex endoscopic endonasal surgery", Postgrad Med J, 79, pp.686~690 (2003)
  15. Schicho K, "Accuracy of treatment planning based on stereolithography in computer assisted surgery", Med Phys, 33, pp.3408~3417 (2006)
  16. Jones RM, "The validity of a computer-assisted simulation system for orthognathic surgery (CASSOS) for planning the surgical correction of class III skeletal deformities: single-jaw versus bimaxillary surgery", Int J Oral Maxillofac Surg, 36, pp.900~908 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (7건)